Facilities Management Division, Bangalore
HINDUSTAN AERONAUTICS LIMITED Facilities Management Division, Bangalore
Lift for HAL Gnanajyothi School HGS, CTS, HAL Bangalore.
9714
TENDER NOTICE/NCP/29/24-25/02
Works
Contract Section Civil-FMD-Bangalore
₹0
₹40,400
18 Nov 2024
21 Sept 2024
21 Sept 2024
18 Nov 2024
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, Contractor registration No etc.,
Address for correspondence:
PAN No.:
Service Tax Registration No
Goods and Service Tax ID No.
Contact details
Please Enter Contact person Name
Pls Enter Mobile No
Registered Contractor
Average annual financial turn over during the last 3 years, ending 31st March 2023 of the previous financial year [ should not be less than 30% of Amount put to tender]
TURN OVER IN Rs.
Pls Enter Turn over in Rupees for all the 3 years
ESI & PF Nos with proof
Remarks if any
Bank(s) details: [Copy of the cheque leaf to be uploaded]
Related Document to be Uploaded to eProcurement Portal (Note Canceled cheque leaf to be uploaded)
Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued NOT before 12 months from the last date of Tender submission
Pls Enter Details to 'Name of the Bank' , 'Date of Issue','Value in Rs
Experience of having successfully completed similar works during last 7 years ending last day of previous month. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of Amount put to the tender.
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Please enter Details for Work No 1
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No II
work done
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No III
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
Pls Enter Details for Person holding Power of Attorney
DECLARATION I
DECLARATION II
Pls Accept the Delaration II
Specification
Removing / transporting the surplus excavated earth including debris, vegetation waste etc., to a distance upto 5000m/ outside HAL premises/ to contractor's own yard including loading, unloading, depositing, spreading, levelling, etc., all complete as directed by Engineer-in-Charge.
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, etc., all complete as directed by Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas in all kinds of soft / hard soil for foundations, footings, column pedestals or members as per the drawing etc., (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including removal of vegetation and in-equalities, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, levelling, ramming the bottom of excavation, getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m with all labour, tools & tackles, plant & machinery, hire & fuel charges, etc., all complete as directed by Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas in all kinds of soft / hard soil for foundations, footings, column pedestals or members as per the drawing etc., (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including removal of vegetation and in-equalities, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, levelling, ramming the bottom of excavation, getting out and disposal of excavated earth lead upto 50 m and lift from 1.5m to 3m with all labour, tools & tackles, plant & machinery, hire & fuel charges, etc., all complete as directed by Engineer-in-Charge.
Returning / filling in with useful excavated soil (excluding rock), free from salts, organic or other deleterious matter (Other than black cotton soil & rock etc., in trenches, plinth,sides of foundations etc., spreading in layers not exceeding 20 cm thick, watering, breaking / removing clods exceeding 50 mm, ramming and consolidation of each deposited layer etc., with all labour, tools & tackles, plant & machinery, etc., lead upto 50 m and for all lifts, etc., all complete as directed by Engineer-in-Charge.
Supplying, mixing and placing plain cement concrete (1:2:4) (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate) of required thickness using 20 mm nominal size down graded hard stone/granite aggregate in accordance with IS 456 in Cills, fillets, coping,etc upto floor five level, including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., but excluding the cost of centering, shuttering and finishing, etc., all complete as directed by Engineer-in-Charge.
Supplying, mixing and placing plain cement concrete (1:4:8) (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate) of required thickness using 40 mm down graded hard stone/granite aggregate in accordance with IS 456 in foundations, mass concrete, sub bases and other similar works including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., but excluding the cost of centering, shuttering and finishing, etc., all complete as directed by Engineer-in-Charge.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary curing, excavation, levelling & dressing & finishing the top smooth, etc., all complete as directed by Engineer-in-Charge.
Formwork (Centering and shuttering including strutting, propping etc, and removal of form) for the following RCC members which are defined as below, in fair finished by providing timber, wooden planks, runners / M.S. sheets with all supports, struts, braces, wedges, scaffolds, bracings, ladders, gangways, dressing with oil including M.S. bolts nuts and washers, temporary openings, filleting for a stop, chamfered edges, internal / external splayed, rounded angles or grooves for forming throating including making temporary openings in the forms for pouring concrete etc., all complete as directed by the Engineer-in-Charge for the sub-items mentioned below. Note: Formwork material is contractor's own property and shall be removed after completion of work.
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
For Roofs, landings, Slabs supported on walls, roof landings, balconies, access platforms, canopies, decks etc.
Lintels, Beams, etc
For Columns, Pillars, Piers, etc
Supplying, straightening, fabricating (cutting & bending), placing in position and binding steel reinforcement of TMT bars of not less than Fe 500 D conforming to IS 1786 for all concrete reinforcment members / works above/below plinth level, including cutting to length, bending to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with mild steel wire (Annealed) not less than 0.9 mm dia or securing with clips, including fixing and bracing, wastage, welding, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it etc., complete all as per specifications, drawings and as directed by the Engineer-in-Charge. Note : a) Only authorized laps, chairs etc. shall be considered for measurement. b) The exposed Reinforcement bars shall be coated with cement slurry.
Providing and laying in position ready mixed or site batched M25 Grade with minimum cement content of 330 kg/m3 design mix cement concrete for reinforced cement concrete work; using coarseaggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, consolidation, levelling, curing, scaffolding, all materials, labour, carriage for all leads & lifts; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-Charge. Note: (i) Site design mix to be obtained from Govt. / NABL laboratory for site batching concrete. (ii) Small quantity is as approved by EIC in volumetric proportion.
All works upto plinth level including necessary openings and packing if any for laying pipes, cables etc.
All works above plinth level upto floor V level including necessary openings and packing if any for laying pipes, cables etc.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes, including hoisting and setting in position with cement mortar 1:6 (1 cement : 6 coarse sand) and along with necessary finishing, making or leaving holes & chases and making good, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless bolts etc., of required size, on the top of the floor or the side of waist slab or to the sides of corridor with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.), etc., all complete as directed by the Engineer-in-Charge.
Providing and laying flamed finish Granite stone of Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent colour flooring in required design and patterns, pathways, flooring,walls, etc in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing, round nosing, etc., all complete as directed by the Engineer-in-Charge.
Providing and laying Polished Granite stone slab of 18mm thick all colours and texture in required design and pattern for wall lining over 12mm thick bed cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing with pigment and white cement all complete including staging /scaffolding etc., curing, polishing, round nosing, etc., all complete as directed by the Engineer-in-Charge.
Providing, fixing, testing and commissioning single socketed pipes of 110mm dia, on wall face unplasticised Rigid PVC rain water pipes of 6 kg/cm² SWR grade and of approved make conforming to IS : 13592 Type A, including jointing together with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion and all necessary fittings & specials, bends, branches, sockets, clamps, pipe cutting and wastages, cutting and making good the walls, connecting to existing lines etc., along with removal of existing rain water pipes, etc., all complete as directed by the Engineer-in-Charge.
Providing, applying and laying 12 mm thick cement plaster work in for internal/ External areas of Ceilings, Chajjas etc in CM(1:4) including forming grooves n.exc 10mm wide and n.exc 10mm deep as per requirement as directed including preparation of surface by hacking etc., at all levels with necesary materials, labour, scaffoldings, curing, tools and tackles, plants etc., threading if any, etc., all complete as directed by the Engineer-in-Charge.
Providing, applying and laying cement mortar (1:6) plastering 15 mm thick on brick/solid blocks/concrete surfaces, finished even and smooth with trowel for Internal walls etc., including supply and fixing of hexagonal chicken mesh minimum 150 mm wide having opening 20 mm x 20 mm of 26 gauge at juncitons of concrete & brick work or between different material, including making grooves as per the requirement n.exc 10mm width and n.exc 10mm deep with necesary materials, labour, scaffolding, curing, tools and tackles etc., at all heights, etc., all complete as directed by the Engineer-in-Charge.
Providing, applying and laying 18 mm thick cement plaster work in two coats for external areas Up to Height of 10.0m as directed. First coat 12 mm thick in cement mortar (1:5) made rough to recieve top coat, second coat 6 mm thick in cement mortar (1:6) , final surface finished with a floating coat of neat cement after necessary preparation of surface, at all levels including supply and fixing of hexagonal chicken mesh minimum 150 mm wide having opening 20 mm x 20 mm of 26 gauge at juncitons of concrete & brick work or between different material, with necesary materials, labour, scaffoldings, curing, tools and tackles, plants etc., threading if any, etc., all complete as directed by the Engineer-in-Charge.
Providing, applying and laying 18 mm thick cement plaster work in two coats for external areas Above the Height of 10.0m to 18m as directed. First coat 12 mm thick in cement mortar (1:5) made rough to recieve top coat, second coat 6 mm thick in cement mortar (1:6) , final surface finished with a floating coat of neat cement after necessary preparation of surface, at all levels including supply and fixing of hexagonal chicken mesh minimum 150 mm wide having opening 20 mm x 20 mm of 26 gauge at juncitons of concrete & brick work or between different material, with necesary materials, labour, scaffoldings, curing, tools and tackles, plants etc., threading if any, etc., all complete as directed by the Engineer-in-Charge.
Painting the exterior walls with tow coats of Premium Acrylic Smooth exterior apint with silicone additives of required shade including preparation of the surfaces, a coat of exterior wall primer and two coats of paint as per manufacturers specification, etc., all complete as directed by the Engineer-in-Charge.
Painting the Interior Walls with two coats of Premium Acrylic Smooth Interior paint with low VOC of required shade including preparation of the surfaces, a coat of primer on wall and ceiling as per manufacturers specification, etc., all complete as directed by the Engineer-in-Charge.
Laying and compacting of granular sub-base in flooring, subbases,ramps, etc upto plinth level of requisite grading by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and applying white cement based putty of average thickness 1mm of apporved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth, etc., all complete as directed by the Engineer-in-Charge.
Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead for thickness above 40mm to 75mm, etc., all complete as directed by the Engineer-in-Charge.
Demolishing brick work built in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead, etc., all complete as directed by the Engineer-in-Charge.
Demolition of bituminous road, soling, sub bases, etc., of any description including stock piling at designated location and disposal of demolished material (Except saleable materials) outside HAL to a distance not exceeding 5 km and stacking servicable and unservicable materials seperately etc., all complete as directed by the Engineer-in-Charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: Of area beyond 3 sq. metres, etc., all complete as directed by the Engineer-in-Charge.
Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in Channels, angles, tees and flats, etc., all complete as directed by the Engineer-in-Charge.
Aluminium work for doors, windows, ventilators with Powder coated aluminium windows (minimum thickness of powder coating 50 micron) & ventilators in moving position including providing and fixing hinges/ pivots and making provision for fixing of fittings like u clamps etc., wherever required including the cost of EPDM rubber / neoprene gasket required , all complete as per the architectural drawings and the directions of Engineer-in-Charge .
Providing and fixing glazing in aluminium/upvc door, window, ventilator shutters and partitions etc. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) along with EPDM rubber / neoprene gasket etc. all complete as per the architectural drawings and the directions of Engineer-in-Charge .
Providing and laying Integral cement based water proofing treatment With average thickness of 120 mm and minimum thickness at khurra as 65 mm. including preparation of surface as required for treatment of roofs, (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by
Rupees Sixteen Lakh Nineteen Thousand Eight Hundred Thirty Two and Eighty Eight Paise Only
Supply, fixing directly to the ceiling/wall testing and commissioning of 10W LED bulkhead light fitting with die cast aluminium body with Poly carbonate front cover, including driver, the driver shall have PF >0.9 and Colour temprature shall be >5600K, IP65 rated THD <20% operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures complete in all respect and as directed by EIC. The lighting fixture shall be of CROMPTON LBHP-10-CDL/ Equivalent make in other approved makes.
Distribution Board
16 Way SPN MCB DB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40amps. ratings , 4P MCB, "C" curve, 10 KA breaking capacity.
32A, 415V gr. 4P 300mA RCBO
16A 250V gr. DP MCB
Lighting Point wiring
Wiring to single light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Supplying and fixing following suitable size GI Box with modular plate and cover on front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16A modular socket outlet and 15/16 A modular switch, connections etc., as required.
Supply & laying in the already excavated cable trench/cable tray/fixing on wall/duct wall with necessary M.S clamps / encasing in pipes etc., testing & commissioning of following size and conductor XLPE insulated armoured power cable of 1.1 KV grade confirming to IS: 7098 ( part-I)/1998 with upto date amendment including stacking at site, proper storage complete etc. as required
4 CX 6 Sqmm Aluminium armoured conductor.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
4C x 6 Sqmm.Al Arm LT cable.
Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required as per CPWD specification and as directed by Engineer In Charge.
Supplying & laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm) as per CPWD specification and as directed by Engineer In Charge.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Wiring for circuit/ submain wiring/ power points along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit including supply & fixing of PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Rupees Ninety Three Thousand Eight Hundred Forty Five and Sixty Five Paise Only
Rupees Seventeen Lakh Thirteen Thousand Six Hundred Seventy Eight and Fifty Three Paise Only
Approximate Amount Put to Tender
Rupees Three Lakh Eight Thousand Four Hundred Sixty Two and Thirteen Paise Only
Rupees Twenty Lakh Twenty Two Thousand One Hundred Forty and Sixty Seven Paise Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
TN29.pdf
TENDER_DOCUMENT • 1.33 MB
55ECSForm.pdf
TENDER_DOCUMENT • 0.48 MB
55Undertaking.pdf
TENDER_DOCUMENT • 0.57 MB
55PQF.xlsm
TENDER_DOCUMENT • 0.03 MB
55PBF.xlsm
TENDER_DOCUMENT • 0.04 MB
55TB.pdf
TENDER_DOCUMENT • 3.35 MB
55PB.pdf
TENDER_DOCUMENT • 0.38 MB
55PQ.pdf
TENDER_DOCUMENT • 0.21 MB
55TenderDrawing.pdf
TENDER_DOCUMENT • 0.03 MB
55Checklist.pdf
TENDER_DOCUMENT • 0.19 MB
Amendment.pdf
TENDER_DOCUMENT • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .