| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹44.6 L+₹4.2 L (10.4%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹47.3 L+₹6.9 L (16.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹49.0 L+₹8.5 L (21.1%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹59.3 L+₹18.8 L (46.5%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
21 Mar 2020, 6:00 pmClosed
GE E/M BASE HOSP DELHI CANTT
GE E/M BASE HOSP DELHI CANTT
REPAIR/MAINT, MANNING AND OPERATION OF CENTRAL AC PLANT DX TYPE UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
2020_MES_326611_1
GE/BH-63/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE E/M BASE HOSP DELHI CANTT
Meeting enlistment criteria of MES with regard to having satisfactory completed requisite value works annual turnover, working capital, fixed assets. No recovery outstanding in any govt dept security clearance etc.
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSP DELHI CANTT
₹99,800
Yes
31 Mar 2020
22 Feb 2020
23 Mar 2020
22 Feb 2020
21 Mar 2020
7 Mar 2020
Amount
Manning and operation of Central Air Conditioning plant DX type at GE Centre of Capacity 4 X 15 TR round the clock in 03 Shifts including Saturday, Sunday & Holidays with One Operator in each shift (Total 03 Operator) for operation of compressor with motors, condensser with motor, AHU with motor, colling tower with motor, electric control panel including valves, gauges as installed complete, and to maintain in side desire condition of temp 22 ± 2 degree C and humidity 50% ± 10% and carry out general cleaneness, routine maintenace, attending all nature of breakdown/complaint, Supply and maintaining log sheet with other connected documents complete all as specified and as directed. (Timings:- Shift-I 0600 to 1400hrs, Shift-II 1400hrs to 2200hrs, Shift-III 2200 hrs to 0600hrs.)
All as per item No 1 here in-before but central AC plant of Open Heart of Capacity 3 X 12.5 TR round the clock on three shifts including Saturday, Sunday & Holidays with One Operator in each shift (Total 03 Operators) complete all as specified and as directed.
Notes For item Nos 1 & 2 here-in-before:- (i) The estimated cost of the work in respect of BOQ Sir item Nos 1 & 2 (as based on minimum wages rates issued vide central/state) is Rs 16,90,000/-. If the quoted amount is found less than the estimated cost of Sir item Nos 1 & 2 of BOQ and tender of lowest bidder is considered for acceptance, then the lowest bidder shall have to deposit FDR in favour of Accepting officer for the difference in estimated cost and Accepted amount in respect of BOQ Sir item Nos 1 & 2 within 30 days from date of acceptance. In case the said FDR is not submitted within 30 days the amount in question shall be recovered from contractor’s first RAR/Final bill whichever is earlier. However the FDR/recovered amount shall be released to the contractor after satisfactory completion of work. Attention is further invited added that when the amount of said recovery mentioned herein above is less than the amount of performance security as indicated under Clause 02 on page 04 of CA and Clause 12 on page 11 of CA, no FDR is required to be submitted for quoting less rate against BOQ Srl Item No 01. However if the amount of performance security is less than the FDR to be submitted for less quoting rate, the difference of performance security amount and FDR amount(for less quoting rates) shall be deposited by the lowest bidder (whose tender is accepted) in the form of FDR for difference amount over and above performance security within 30 days from the date of Acceptance. (ii) One operator/technician shall perform only one shift of 08 hours in a day. If the same operator/technician found in other shift, a recovery of Rs 500/- per day shall be recovered from the contractor's dues.
(iii) Contractor shall submit the nominal roll and qualification of operator/technician within 15 days of acceptance of tender. After that penalty for a sum of Rs 500/- per shift per installation shall be recovered from the contractor's dues. (iv) Contractor shall ensure attendance of all operator/technician in shift wise. If any operator/technician found absent from duty a sum of Rs 1000/- per shift per person shall be recovered from the contractor's dues. Any damage of loss on this account shall bear by the contractor. (v) All operator/technician shall wear proper uniform, failing which a recovery of Rs 200/- per shift per person shall be recovered from the contractor's dues. (vi) The payment of contractor's employee shall be made through nationalized bank account of individual and the proof of transaction and the contractor shall submit the same with bank account pass book of individual within 15 days of acceptance otherwise a recovery shall be made a sum of Rs 200/- per shift per employee from the contractor's dues.
M&L for descaling of condensser tube of central AC plant of capacity 3 x 75 TR by disconecting the condensser from the system, cleaninh by descaling pump of suitable capacity of 110 ' feet head using descaling solution of make Hibird or descaling solution, cleaning condenssor tube by nylon bursh & MS rod of suitable size, replacement of rubber joints and unserviceable nut bolts complete all as specified and as directed. (Note:- (i) Arrangment of T&P such as pump, tube, descaling solution shall be carried out by contractor. (ii) Descalling of all respective condensors shall be considered as one job)
All as per Ser items No 3 here-in-before but 3X60TR complete all as specified and as directed.
All as per Ser items No 3 here-in-before but 3X40TR complete all as specified and as directed.
All as per Ser items No 3 here-in-before but 3X30TR complete all as specified and as directed.
All as per Ser items No 3 here-in-before but 3X15 TR complete all as specified and as directed.
All as per Ser items No 3 here-in-before but 2X15 TR complete all as specified and as directed.
All as per Ser items No 3 here-in-before but 4X15 TRcomplete all as specified and as directed.
All as per Ser items No 3 here-in-before but 3X20 TR complete all as specified and as directed.
Supply, Installation, testing and commissioning 12 HP VRF based outdoor unit with Heat pump system and inverter driven capacity control compressor, with special acryl pre coated e-pass heat exchanger, low noice condenser fan with DC motor, auto check function for connection error, auto address setting etc (2 piping system for Heating and cooling) complete with Control Kit EEV for operating the locally provided AHU with direct expansion heat exchanger coils in connection with VRF system, (EEV-KIT is composed of EEV control ASSY and one EEV - set as recommended by OEM to operate 12 HP out door unit and AHU) MS stand and coonected accessories and control and power copper cabling, Wire remote control and display screen all as recommended by OEM of VRF machine compitable with PLC/BMS based compitable for running of DX type AHU 3500 CFM with following specifications with 70 KVA servo voltage stablizer suitable for 3 Phase, 50 HZ, 4 wire system all as specified and directed by Engr-in-Charge. (Note: Old unserveciable outdoor AC unit of any capacity shall be deposited at MES store yard for further disposal.)
Capacity :- 12 HP, Make :- Mitsubishi Heavy Industries ,Model No :- FDC335KXZE1 and EEV Kit Model No EEV6- 280 - E or equivalent in Daikin, O General Power Sourch :- 3 Phase, 380-415V, 50 HZ Nominal Cooling KW :- 33.5 KW Nominal Heating KW :- 33.5 KW Electrical Characteristics:- Staring current :- 8 A Running current Heating Mode :- 14.6 to 13.4 A Running current Cooling Mode :-14.8 to 13.5 A Exterior dimensions :- 1690 x 1350 x 720 mm Net wight :- 272 KG Refrigerent charge :- R410A in complete system including AHU complete Sound pressure level in Heating / Cooling :- 61 /58 db(A) Refrigerent piping size :- Liquid line :- dia 12.7 mm ( 1/2") Gas Line :- dia 25.4 mm ( 1 ")
Note:- (i) Contractor shall arrange factory inspection / Training schedule for minimum three nos JE E/M & AGE E/M to train all person about the system and fault finding mechanisum for electrical and electronic circuit upto satisfaction of all the person. (ii) Contractor shall provide following air conditioning tools to the MES for day to day maintenance of VRF system. (a) Total Ricovery unit heavy duty (Gas & Oil for central AC plant) - 01 Nos all as approved by Engr-in-charge. (b) Dual Stage Vaccum pump for central AC Plant of specification Flow rate :- 12 CFM, ultimate vacuum :- 2x10-1 pa - 01 No. (c) Charging line universal type - 06 Nos (d) Gauge manifold - 01 No. (e) Oxigen and LPG cylinder kit 5 Ltr capacity combined with brazing torch, flexible rubber hose miniumum 20 mtr length, regulating valves for both oxigen and LPG cylinder compete all as specified and directed by engg -in-charge - 01 Nos set (f) flaring tools complete set all as specified and directed by Engr-in-charge - 01 No.
S&F Refrigerant "Y" joint required for distribution copper piping as per recommended by OEM suitable for Capacity - 12 HP complete all as specified and as directed, Make :- Mitsubishi Heavy Industries, Model No :- FDC335KXZE1 or equivalent Model of Daikin/ O General.
Supply, installation, testing and commissioning refrigerant copper piping of following sizes covered with 19mm thick closed cell elastomeric nitrile rubber tubular insulation, between each set from AHU to VRF unit as per OEM standards and supported with MS hangers complete all as specified and as directed:-
(a) 38.1 mm internal dia
(b) 34.92 mm internal dia
(c) 28.58 mm internal dia
(d) 22.22 mm internal dia
(e) 19.05 mm internal dia
(f) 15.88 mm internal dia
(g) 12.7 mm internal dia
(h) 9.52 mm internal dia
(j) 6.4 mm internal dia
Supply, installation, testing and commissioning of 2 core 1.5 sqmm 1100V grade PVC insulated copper conduction laid in 20 mm dia medium grade PVC conduit with necessery clamp complete all as specified and as directed.
S&F in repair DX TYPE coil with fins, 32 Sq.ft coil area, GI coil casing / blank offs, coil section with 4 row with single number of distributers, copper tube material, 9.52mm tube dia, 25 SWG/ 0.5 mm thickness of tube, 4 RD cooling, coil copper header matreial and 0.15 mm thick plain aluminium fins with No. of fins per inch 11/12 Suitable for 16000 CFM, 50 (mm wg) static pressure and AHU Make:- ZECO, AHU Model:- ZDAW-160 along with connected fixing brackets etc complete all as specified and as directed. Make of Coil :- ZECO/ AIREF/ UNIVERSAL.
Note :- (i) Contractor shall carried out complete pump down the system with recovery unit and take all refrigerent Gas from the system in refrigerent bottle with recovery unit and store at safe place for reuse. (ii) Contractor shall arrange necessary T &P and experience technician to carring out cutting of existing copper pipe lines from expansion valves to AHU Coils and supply and fixing with addition alteration to new copper tubing as recommended by OEM. (iii) Cost of following works shall also deemed to be included in the rates quoted by the contractor:- (a) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of AHU Coil and cutting and addition alteration with copper tuning. (b) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any. (c) Charging of complete system with R - 22 gas stored in bottle recover from system for maintaining the system pressure up to HP - 175 psi & LP - 65 psi. (d) Measure the inlet and outdoor temperature of package unit and maintain temperature as per required at site. (e) Testing & commissioning of compressor after completion.
S&F in repair 50 mm thick box type Pre-Filter (EU-4) Synthetic type (non woven type), area of filter-32.0 Sq. ft, efficency - 90% down to 10 micron with complete all fitting sutiable for 16000 CFM and 50 mm wg static pressure, AHU model No:- ZDAW-160, AHU Make :- ZECO complete all as specified and as directed. Make for Filter :- Thermadyne/ Spectrum/ Puramatic/ Mechmaark
Supply, laying, testing and commissioning of XLPE insulated PVC armoured heavy duty PVC sheathed 1100 volts grade with aluminium conductor 4 CORE 16 sqmm size after taking down old existing unserviceable cable from trenches/ducts/road crossing or along poles/walls etc complete all as directed. (Note: Old unserveciable cable shall be deposited at MES store yard for further disposal.)
Supply, laying, testing and commissioning of XLPE insulated PVC armoured heavy duty PVC sheathed 1100 volts grade with aluminium conductor 4 CORE 25 sqmm size after taking down old existing unserviceable cable from trenches/ducts/road crossing or along poles/walls etc complete all as directed. (Note: Old unserveciable cable shall be deposited at MES store yard for further disposal.)
Supply, installing, testing and commissioning Outdoor type LT Feeder Pillar Panel, floor mounted, CPRI approved suitable for 415 volt, 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with duly insulated Aluminum Bus bars of rating 200 Amps mounted on epoxy/SMC type insulator. The panel shall be dust and vermin proof IP 54 class protection and made out of 14 SWG CRCA sheet and 50 mm x 50 mm x 6mm thick angle iron frame work, 90 Cm height and grouted 45 Cm in PCC, powder coated finish outside and inside, both side (front and rear) openable type for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated flexible copper conductor FRLS cable IS 694 marked of adequate size but not less than 1.5 sq mm complete including LED phase indicators, digital Voltmeter and Ampmeter suitable for and inclusive of the following incoming and outgoing feeders accessories complete all as specified and as directed:- Note:- (i) Rate quoted by the Contractor shall be inclusive of all foundation/ Base work i.e earth work/ PCC/ Plastering etc (ii) Old unserveciable DB/ Panel of any capacity with accessories shall be deposited at MES store yard for further disposal.)
(a) Incoming :- MCCB TP + NL , LT 415 Volts, 50 Hz, AC grade, 200 Amps rating and 36 KA. - 01 No. (b) Outgoing :- (i) MCCB TP + NL , LT 415 Volts, 50 Hz, AC grade, 100 Amps rating and 16 KA. - 01 No. (ii) MCCB TP + NL , LT 415 Volts, 50 Hz, AC grade,63 Amps rating and 16 KA. - 02 Nos.
Supply, installing, testing and commissioning Outdoor type LT Feeder Pillar Panel floor mounted, CPRI approved suitable for 415 volt, 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with duly insulated Aluminum Bus bars of rating 200 Amps mounted on epoxy/SMC type insulator. The panel shall be dust and vermin proof IP 54 class protection and made out of 14 SWG CRCA sheet and 50 mm x 50 mm x 6mm thick angle iron frame work, 90 Cm height and grouted 45 Cm in PCC , powder coated finish outside and inside, both side (front and rear) openable type for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated flexible copper conductor FRLS cable IS 694 marked of adequate size but not less than 1.5 sq mm complete including LED phase indicators, digital Voltmeter and Ampmeter with the following incoming and outgoing feeders. Note:- (i) Rate quoted by the Contractor shall be inclusive of all foundation/ Base work i.e earth work/ PCC/ Plastering etc (ii) Old unserveciable DB/ Panel of any capacity with accessories shall be deposited at MES store yard for further disposal.)
(a) Incoming :- MCCB TP + NL , LT 415 Volts, 50 Hz, AC grade, 250 Amps rating and 36 KA. - 01 No. (b) Outgoing: :- (i) MCCB TP + NL , LT 415 Volts, 50 Hz, AC grade, 63 Amps rating and 16 KA. - 08 Nos. (ii) MCCB TP + NL , LT 415 Volts, 50 Hz, AC grade, 100 Amps rating and 16 KA. - 02 Nos.
M&L earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 Mtrs below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised earth strip 32 x 6mm size by means of bolts, check nuts and washers of galvanised steel, 20 mm bore, galvanised iron, medium grade watering pipe, and 40 mm bore galvanised iron light grade for protection of earth strip including all excavation, earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / Sqm) with cast iron frame, with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 Mtrs below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers of galvanised steel, 20 mm bore, galvanised iron, medium grade watering pipe, and 15 mm bore galvanised iron light grade for protection of earth lead including all excavation, earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / Sqm) with cast iron frame, with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion complete all as specified and directed.
Supply and charging refrigerant gas R-410a complete all as specified and as directed. Make:- Floron/ Refron
Supply and charging refrigerant gas R-134a complete all as specified and as directed. Make:- Floron/ Refron
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth for foundation/laying cable etc and getting out.in soft/loose soil complete all as specified and as directed.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated materials not exc 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Supply & laying sub class B bricks having minimum compressive strength 75 Kg/Sqcm laid in trenches for cable protection etc complete all specified and as directed.
HVAC Engineering Co
ARE ESS ENGINEERING SERVICES
RUCHIKA ENGG.WORKS
Saini Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .