Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹11.9 L+₹2.1 L (21.1%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹13.3 L+₹3.5 L (35.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Nal, Bikaner
GE (AF) Nal, AF Stn Nal Bikaner (Raj)-334001
As described in Bill of quantities
2021_MES_452065_2
GE (AF) NAL/T-07/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE (AF) Nal
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Nal
₹30,000
Yes
GE (AF) NAL
18 Nov 2021
17 Aug 2021
24 Sept 2021
17 Aug 2021
16 Sept 2021
28 Aug 2021
17 Aug 2021 - 21 Aug 2021
23 Aug 2021
60 days
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m deep, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed
Removal of excavated material / soils to a distance n exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm in soft / loose soil complete all as specified and directed.
M&L sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. Note : 18 cm thickness as consolidated shall be consider for payment purpose
Supply & Laying bricks using sub class ‘B’ bricks (old size) for cable protection laid flat and dry in trenches over cable perpendicular to direction of cable, complete all as specified and directed.
Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor 2 core 10 sqmm from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item is also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.
All as per description of serial item No. 6.00 here in before but size of cable 4 core 16 Sqmm
All as per description of serial item No. 6.00 here in before but size of cable 3.5 core 25 Sqmm
All as per description of serial item No. 6.00 here in before but size of cable 3.5 core 35 Sqmm
All as per description of serial item No. 6.00 here in before but size of cable 3.5 core 50 Sqmm
All as per description of serial item No. 6.00 here in before but size of cable 3.5 core 95 Sqmm
All as per description of serial item No. 6.00 here in before but size of cable 3.5 core 120 Sqmm
All as per description of serial item No. 6.00 here in before but size of cable 3 core 120 Sqmm, 11000 volts grade
All as per description of serial item No. 6.00 here in before but size of cable 3 core 185 Sqmm, 11000 volts grade
Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed.
All as per description of serial item No. 15.00 here in before but size of cable 4 core 16 Sqmm
All as per description of serial item No. 15.00 here in before but size of cable 3.5 core 25 Sqmm.
All as per description of serial item No. 15.00 here in before but size of cable 3.5 core 35 Sqmm.
All as per description of serial item No. 15.00 here in before but size of cable 3.5 core 50 Sqmm.
All as per description of serial item No. 15.00 here in before but size of cable 3.5 core 95 Sqmm.
All as per description of serial item No. 15.00 here in before but size of cable 3.5 core 120 Sqmm.
All as per description of serial item No. 15.00 here in before but 11 KV HT cable of size 120 sqmm 3 core
All as per description of serial item No. 15.00 here in before but 11 KV HT cable of size 185 sqmm 3 core
Dismantling insulators any type, any size from its original position and removing from site complete all as specified and directed.
S&F pin type porcelain vitreous white or brown insulator incl one galvanised MS spindle, two washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade fixed on poles/cross arms of upto 9 m long complete all as specified.
All as per description of serial item No. 25.00 here in before but 150mm height, 150mm dia for 11000 volts grade.
S&F shackle type porcelain vitreous white/brown or green insulator incl galvanised mild steel straps, washers, insulator bolts, washers and nuts for working pressure 1100 volt section of strips 31x5 mm bolt dia 14 mm max dia 115 mm, height 100 mm fixed on poles/cross arms of upto 9 m long, complete all as specified.
S&F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, 'Two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
Material and Labour boring of road crossing of size 100mm dia by using trenchless technology with use of machinery equipments complete without damaging the surface at suitable depth for drawing cables/pipe lines etc. complete all as directed. Note : (i) Location of boring holes shall be decided by the Engr-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer is hereby advised to keep in mind this aspect while quoting his rates.
Dismantling and taking out the old stay assembly complete incl demolition of plain cement complete all as specified and directed. Note : (i) Unit rate of this item includes the loose/disconnect the all accessories which are connected to stay assy includng necessary excavation as directed. (ii) Existing stay assembly are fixed on the LT/HT pole of PCC or steel tubular pole, nothing extra shall be paid on this account.
Material and Labour Stay assembly complete with accessories as shown in electrical plate No 1 incl GI Adjustable Stay Rod of 16 mm Dia, GI Stay wire of size 7/4 mm incl stay clamps, loop type insulator, excavation in any strata and PCC 1:3:6 C-1 (using 20 mm graded stone aggregate) concrete complete all as specified and directed. Note:- Unit rate of this item includes the cost of earthwork, loop type insulator, PCC and stay wire.
Dismantling and taking down air break gang operated switch vertical / horizontal mounted including insulators and operating mechanism / replacement of old unserviceable air break switches of 400/200 Amps complete all as specified and directed.
Supplying and fixing installing, commissioning and testing HT 11KV, 3 phase system, outdoor type gang operated switch, air break type suitable for vertical mounting complete with necessary insulators and separators, set of drop out fuses (12 insulators) and operating handle of GI pipe 25 mm bore, medium grade rod of suitable length (mechanically operating arrangements), locking arrangement with lock and two keys complete of rating 400 Amp complete all as specifiedand directed.
S&F as in repair drop out fuse assembly complete set with Insulator-06 Nos and connected accessories for 11000 V grade with suitable size of drop out fuses complete all as specified and directed.
M&L preparation of old surfaces of HT PCC pole upto 1.5mtr height from coping and painting with two coats of synthetic enamel paint in alternative red and white strips of 30cm each and writing pole numbers with black paint complete all as specified and directed.
All as per description of serial item No. 35.00 here in before but two pole structure with HT poles and strips in red and white colour
All as per description of serial item No. 35.00 here in before but four pole structure with HT poles and strips in red and white colour
M&L preparation of old surfaces of LT PCC pole upto 1.5mtr height from coping and painting with two coats of synthetic enamel paint in alternative black and white strips of 30cm each and writing pole numbers with black paint complete all as specified and directed.
Material and labour two coats of silver/aluminium paint on steel tubular LT pole including on MS work like channel cross arms, nut, bolts & washer, street light bracket and clamps above 1.50 metre from top of PCC coping and two coats of synthetic enamel paint in alternative black and white strips of 30 cm each upto 1.50metre from top of PCC coping including scrapping the existing paint and the preparation of surfaces complete all as specified and directed. Note : Unit rate of this item includes the following : - (i) Painting shall be done on existing surface except strip portion at bottom of 1.5 mtr height. (ii) All MS work shall also be painted.
Material and Labour removing old stone aggregate any size from 4 pole structures and laying new stone aggregate 40mm size including making good the existing surface upto 15cm depth complete all as spefied and directed. Note : Before laying new stone, existing area shall be neatly cleaned and existing bushes, grass etc shall be removed and thrown away as directed.The quoted rate shall include the cost thereof
Taking down/removing all connections of four pole structure incl all jumpers and complete rejumpering using new ACSR connectors of adequate length through insulated pipes and connections using aluminium lugs/sleeves of directed sizes and treating with conducting jelly and testing of structure before charging with electric supply all to the satisfaction of Engr in charge.
S&F as in repair Mild steel work in framed work such as grills, Gates, Framed guard bars, gratings, ladders, Cable trays, Fencing etc., with ends of bars soldered/welded and/ or riveted, or forged into spikes, and similar work confirming to Fe 290 E-165 incl two coats of mettallic paint over a coat of mettallc primer complete all as specified and directed.
S&F as in repairs lightning Arrestor Expulsion type Transmission Class 65 Kilo Amps 11000 V Grade incl connecting complete all as specified and directed.
Shifting of Transformers upto 630 KVA from one substation to other sub station in the case of any breakdowns by using man power and mechanical means after disconnecting all electric connections and reconnecting in new locations within 263 SU area as directed. Note : (i) Contractor shall provide all the T&P including transportation for shift and nothing extra shall be paid on account of loss of manpower during shift. Tenderer is hereby advised to keep in mind this factor before quoting his rates.
Supply and fix as in repair GI strip 32mm x 6mm burried in ground / laid in floor / fixed to wall on saddles / on porcelain insulators etc complete all as specified and directed. Note : Excavation and earthwork shall be measured and paid for separately.
Material and labour as in repair earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32mmx6mm by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth wire protected by galvanized iron pipe light grade 40mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I).
Supply and fixing as in repair MCCB, 63 Amps, 4 pole, 415 volts, 50 Hz, rupturing capacity 16 KA, connection with proper size of thimbles complete all as specified and directed.
Supply and fixing as in repair MCCB, 100 Amps, 4 pole, 415 volts, 50 Hz, rupturing capacity 16 KA, connection with proper size of thimbles complete all as specified and directed.
Supply and fixing as in repair MCCB, 125A, rupturing capacity 16 KA, 415 volts 4 pole complete all as specified & directed.
Supply and fixing as in repair MCCB, 160A, rupturing capacity 36 KA, 415 volts 4 pole complete all as specified & directed.
Supply and fixing as in repair MCCB, 200A, rupturing capacity 36 KA, 415 volts 4 pole complete all as specified & directed.
Supply and fixing as in repair MCCB, 250A, rupturing capacity 36 KA, 415 volts 4 pole complete all as specified & directed.
Supply and fixing as in repair MCCB, 400A, rupturing capacity 36 KA, 415 volts 4 pole complete all as specified & directed.
Supply, install, testing and commissioning as in repair outdoor type factory made, made out of 3.15mm thick CRCA Sheet CPRI test certified, platform mounted LT panel board of size 0.5m x 0.65 x 0.35m to accomodate the following items and built upon angle iron frame suitable size compartmentalized design work, duly powder coated with gray paint and suitable size of cable glands chromium plated and Aluminium busbars TPN, 200 Amps,415 V,50 Hz complete as following :- (i) MCCB 63 Amps, 3 Poles, 16 KA rupturing capacity - 01 No (Outgoing) (ii) Indicating lamp LED RYB set of three with colour coding - 1 No. Note : Unit rate of this item also includes the following :- (i) Panel shall be fixed as per existing manner and where the excavation and earthwork involved shall be carried out by the contractor as directed. (ii) After errection / fixing of panels, all connection shall be made by the contractor as directed. (iii) The existing surface shall be made good by the contractor to the entire satisfaction of Engineer-in Charge.
M&L trimming of tree branches on both sides of LT aluminium conductor overhead complete all as specified and directed. NOTE : (i) Cutting branches shall be dumped outside the air force premises. (ii) Contractor shall provide the ladder of required size including T&P to his worker and nothing extra shall be paid on this account. (iii) Before commencement of trimming work, elctric shutt down shall be got managed by the contractor and sufficient man power shall be deployed on the particular time so that the task given by the Engineer-in-Charge shall be completetd with the time allowed. (iv) No separate payment for each side of contractor shall be admissible. However, for payment purposes, actual length covered over the LT line shall be considered.
Supplying and laying as in repairs 80mm bore GI tubing light grade incl all accessories for passing of cables for mechanical proctection, laid under Plinth / Floors / Paths Culverts or fixed on wall or concealed in wall / floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends / sockets / reducers / saddles incl necessary threading / drilling works all as specified and directed. (MS works including painting will be measured under seperate item in Schedule)
All as per description of serial item No. 56.00 here in before but 50 mm bore
Taking out and Re-laying of existing HT/LT UG cable of any size after jointing using LT cable joining kit complete all as specified and directed. Note : (i) Excavation incl earth work shall be measured and paid for separately. (ii) Joints shall also be measured and paid for separately under respective item of this Schedule (iii) Cable protection i.e. bricks, sand cushioning etc. shall be measured and paid for separately under respective item.
S&F as in repair cable jointing kit straight through heat shrinkable type complete with jointing materials suitable for LT Armoured cables of size upto 50 Sqmm 3.5 core incl necessary excavation & earthwork complete all as specified and directed.
S&F as in repairs cable jointing kit straight through heat shrinkable type complete with jointing materials suitable for LT Armoured cables of size 70 to120 Sqmm 3.5 core incl necessary excavation & earthwork complete all as specified and directed.
S&F as in repair cable jointing kit straight through heat shrinkable type complete with jointing materials suitable for LT Armoured cables of size 150 to 185 Sqmm 3.5 core incl necessary excavation & earthwork complete all as specified and directed.
S&F as in repair cable jointing kit outdoor end termination through heat shrinkable type complete with jointing materials suitable for LT Armoured cables of size upto 50 Sqmm 3.5 core all as directed.
S&F as in repair cable jointing kit outdoor end termination through heat shrinkable type complete with jointing materials suitable for LT Armoured cables of size upto 70 to 120 Sqmm 3.5 core all as directed.
S&F as in repair cable jointing kit outdoor end termination through heat shrinkable type complete with jointing materials suitable for LT Armoured cables of size upto 150 to 185 Sqmm 3.5 core all as directed.
Re-stretching the existing LT/HT over head line consisting of 5/4/3 conductors of any size and one GI wire after removing serviceable/unserviceable separators carefully including opening and reconnecting of jumpers binding conductor over the insulator properly with the help of binding wire 14 SWG and re-fixing separators in its original position complete all as specified and directed. Note: (i) Each run of conductor/wire shall be measured and paid separately (ii) Length of conductor shall be taken between the poles and no sagging element shall be accounted for payment purpose. This aspect shall be kept in mind while quoting the rate
Disconnection of Transformer from HT/LT side at site, dehydration and filtration of the transformer oil with the help of oil filtration plant of any capacity of distribution transformer indoor/outdoor type 11/0.433 KV. Notes:- a) The unit of payment under this item shall be for the oil required for all process to entire completion of the job. b) New oil required for topping up before dehydration & filtration shall be measured and paid separately under relevant item. c) The dielectric strength of oil shall not be less than 45 KV when maintained a gap of 3mm for one minute all as specified and directed. d) All T & P required for dehydration shall be arranged by the contractor at his own. e) Additional transformer oil required for top up shall be measured and paid for separately as 'Supply Only' under respective item of this Schedule.
Supply and filling new transformer oil of superior quality conforming to IS 335:93 complete all as specified and directed. Note:- (i) The dielectric strength of oil should not be less than 60 KV when maintained a gap of 3mm for one minute complete all as specified and directed. (ii) Contractor shall bring the transformer oil in sealed container and after use of oil, container shall be property of contractor and nothing extra shall be admissible on this account..
Supply and fixing as in repair LT bushing assembly complete with insulator, brass stud rod, nuts, washers, gasket etc complete with accessories suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V complete all as specified and directed.
All as per description of serial item No. 68.00 here in before but HT bushing.
Supply and fixing as in repair oil drain valve cast copper alloy any dia suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V of existing make complete all as specified and directed.
Supply and fixing as in repair 6mm thick cork sheet set (Rubberized cork /neoprene) for top cover suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V of existing make complete all as specified and directed. Note:- Size of sheet shall be as per existing cover. Hence, no claim whatsoever shall be entertained by the Deptt for any misunderstanding.
Supply and fixing in replacement breather assembly complete set suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V of existing make complete all as specified and directed.
Supply and replacement silica gel complete all as specified and directed.
Material and labour Spray painting to outer surfaces of transformer upto 630 KVA transformer 11KV / 433V with two coats of synthetic enamel paint after scraping, removing, washing and cleaning of old paint, complete all as specified and directed.
Supply and fixing as in repair temperature gauge suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V as existing make complete all as specified and directed. Note : These transformer are located /fixed at different location and of different sizes, tenderer are hereby advised to see this aspect before quoting their rates and no claim what soever shall be entertained by the department on account any misunderstanding.
S&F as in repair heavy duty double break fuse switch HBC/HRC fuse type TPN 415 Volts 200 amps capacity with 03 Nos HBC fuse link complete all as specified and as directed.
Supply & fixing as in repair cable jointing kit for 11 KV (E) grade for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable upto 120 Sqmm 3 core XLPE cable armoured aluminium conductor complete all as specified and directed. Note : Unit rate of this item also includes the cost of excavation and earthwork though required for replacement of the existing joint.
All as per description of serial item No. 77.00 here in before but of size 95 sqmm 3 core
All as per description of serial item No. 77.00 here in before but outdoor type of size 185 sqmm 3 core
All as per description of serial item No. 77.00 here in before but outdoor type of size 120 sqmm 3 core
All as per description of serial item No. 77.00 here in before but outdoor type of size 95 sqmm 3 core
Supply, jointing & testing as in repair cable jointing kit for 11 KV (E) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 95 Sqmm complete all as specified and directed. Note : Unit rate of this item also includes the cost of excavation and earthwork though required for replacement of existing joint.
Supply, jointing & testing straight through joint 11 KV (E) heat shrinkable type suitable for XLPE HT cable of size 120 Sqmm 3 core, 11000 volts grade complete as specified and directed. Note : Unit rate of this item also includes the cost of excavation and earthwork though required for replacement the existing joint.
Dismantling/taking down old unserviceable ACSR conductors of any size from LT / HTpoles over head electric line after disconnecting from insulators complete all as specified and directed. Note : (i) ACSR conductor are of different sizes and fixed at different locations. No claim whatsoever shall be entertained by the department on account of any misunderstanding. (ii) The contractor shall submit his schedule for dismantling / taking down at least one week before undertaking the work of dismantling ACSR conductor so that the shut down of electricity can be managed accordingly. (iii) T&P required for said job shall be arranged by the contrator at his own end and nothing extra shall be admissible on this account.
Supply and stringing PVC insulated aluminium conductor steel reinforced (ACSR) stretching properly to achieve proper sag on insulators and binding with aluminium tape/binding wire connectors, PG clamps, jumpers etc complete all as specified and directed. Note : (i) The payment of the conductor shall be made on the basis of Board of Officers convened by the Accepting Officer. (ii) 3 % for sag shall be added in measurements (iii) Size of conductor shall be as per site requirement / as directed)
Dismantling of cross arms, supports, clamps and back plates incl nut bolts washers, any shape or size as indicated complete all as directed. Note : (i) Existing MS work is of different sizes and fixed at different locations. While dismantling, ACSR conductor shall be loosened properly as per direction of Engr-in-Charge (ii) The contractor shall submit his schedule for dismantling / taking down at least one week before undertaking the work of dismantling ACSR conductor so that the shut down of electricity can be managed accordingly. (ii) T & P required for dismantling shall be arranged by the contractor at his own cost.
M&L mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from steel section, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. Note : Nuts, bolts, washers shall be measured and paid separately.
S&F PVC line seperator for separating 3 / 4 / 5 LT overhead lines complete all as specified and directed. Note : The length of PVC line separator may be varied hence size of separator shall be as per site requirement, however no claim whatsoever shall be entertained by the Deptt. on this account.
M&L detecting /locating fault of HT 11KV UG cable of size 95 to 185 Sqmm by using pin point fault locator machine complete all as specified and directed. Note: Straight through/cable end joints are measured and paid separately
Dismantling of damaged steel tubular/PCC pole of size 9 mtr for disposal all as specified and as directed. Note : (i) Dismantling of existing pole shall be undertaken only after removal of ACSR conductor, MS Work & insulators etc which shall be measured and paid for separately under respective item of this Schedule. (ii) Unit rate of this item includes the cost of dismantling of PCC and excavation and earthwork complete as directed.
Supply, installation and erection in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged welded poles complete with MS base plate of 6 mm thick of size 300mm x 300mm, finial taper plug, pole cap, bolts, nuts and washers and screwed, pole made out of ERW MS tubing conforming to IS-2713 ( Part II),1980 type 410-SP-31, 9 meters long L.T pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, painting with two coats of aluminium paint over a coat of primer incl marking pole number with paint, Excavation and in any type of strata 1.50metre deep, PCC 1:3:6 foundation / filling upto GL and PCC 1:2:4 coping of size 600mm x 600mm, 300mm deep above GL, complete all as specified and directed Note : Unit rates of this item includes the cost of PCC in foundation, PCC coping and excavation & earthwork
Taking out operating handle with clamps from the GOD switch 200 Amps to carry out repairs by cutting the operating rod to the required length and refixing the GOD switch along with handle and new clamp all as required for smooth operation of GOD switch.
M&L as in repair 40mm thick, 2nd class hardwood planks, n exc. 25 cm in width and fixing on angle iron frame of 2/4 pole structure, screwing with existing iron structure complete suitable length laying adjust one by one including one coat of paint over a coat of pink primer complete all as specified. Note : Width and length of plank shall be as per existing or as directed.
Taking out the damaged / low earth result earthpits and carry out necessary repairs and refilling the charcoal dust, salt and chemical compound as mentioned below :- a) Removing the earthpit cover/earthstrip connections from test point b) Digging the earthpit ranging from 4 feet to 10 feet using 80mm bore pipe as required according to the condition of soil in earthpit c) Filling the earthpit initially with earth enhancing compound and chemically treated earth booster. d) Filling the earthpit by earth compatible charcoal and salt e) Lastly watering the earth pit f) Covering the earth pit with existing covers and testing the earthpit resistance value and connecting the earth strip in its original position. Note : Materials required for replacement shall be measured and paid separately under relevant item as supply
Supply only Earth compatible Charcoal best quality
Supply only Mineral Salt
Supply only Chemically treated earth booster
Supply and fix as in repair heavy duty power shunt capacitor 440v 3 phase 50HZ of type cylinder/box.
Supply and fix as in repair Power contractor 440V, 3 phase, 50 HZ suitable 5 KVAR Rating complete all as specified and directed.
All as per description of serial item No. 99.00 here in before but 8.5/10 KVAR Rating
All as per description of serial item No. 99.00 here in before but 20 KVAR Rating
Disconnecting the HT 11 KV supply from VCB SF6 unit existing in AC Plant, removing the top cover of VCB for carrying out complete servicing of incoming and outgoing feeders (two incoming feeders and three outgoing feeders) completely by air blower and removing the dust deposited over all mechanical parts, oiling, greasing the mechanical moving parts and replacement of minor parts, Caliberation of multi-functional relays, for over current and earth fault and resetting the same as per load on the feeders. Note : Contractor has provide the calibration certificate of VCB from OEO and nothing extra shall be admissible on this account.
Disconnecting the LT 1100V supply from ACB unit existing in Panel, removing the top cover of ACB for carrying out complete servicing of incoming and outgoing feeders completely by cleaning with air blower and removing the dust deposited over all mechanical parts, oiling, greasing the mechanical moving parts and replacement of any worn out parts and testing the ACB for smooth operations, caliberation of relays, for over current and earth fault and resetting the same as per load on the feeders. Note : Spare parts will be measured and paid for separately under relevant items of schedule)
Supply only spring charging motor, 220V, AC/DC supply for ACB
Supply only vertical terminals 800 / 1000 & 630-1250S1 (adopters) for ACB
Supply only jaw contact assembly 630-1250S1 for ACB
Supply only pole assembly 630-1250S1 for ACB
Supply only shunt release EA1, 415V, AC for ACB
Supply only closing preventer, 415V, AC for ACB
M&L easing and adusting loose door shutter of LT panels including replacement of old rusted hinges with new ones by welding complete all as specified and directed. Note:- Cost for use of Welding machine is included in unit quoted rate.
S&F as in repair DOL type starter type suitable upto 7.5 HP motor 3 phase, 415 volts complete all as specified and directed.
M&L Servicing of servo voltage stablizer of capacity 30 KVA / 75 KVA , 3 Phase 50 Hz with testing of wiring and testing with OV,UV protection with reverse phase and overload and replacement of unserviceable parts like controller , servo motor, gear set ,RC ,micro switch complete all as specified and directed. Note :(i) Spare parts will be measured and paid separately under relevant items of schedule. (ii) the make of spare part shall be as per existing make.
supply only following spare parts for 30 KVA / 75 KVA servo stablizer
Micro processor controller
Servo motor 10 kg torque
Relay Control
Micro switch
Gear set
M&L for painting with two coat of synthetic enamel paint on the Surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
M&L as in repair earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly in ground in vertical position, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level. The earth plate to be connetced with copper earthing strip of size 20 mm x 3 mm thick by means of brazing between copper strip and earth plate min 45 cm in vertical length and copper strip also to be joined by brazing only. The copper earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. Earthing shall include provision of funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness ), 3rd layer with tibba sand up to ground level. Earthing shall also include concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 3 of MES Schedule Part-I complete to obtain less than 1 Ohm earth resistance value, complete all as specified. NOTE : (i) Cost of this items includes the scope of earth work, charcoal, salt, PCC, RCC pit cover of required size. (ii) Tibba sand shall be arranged by the contractor at his own and the cost thereof shall be deemed included in unit quoted rate of this item. (ii) Electrical Plate No. 3 refrred in the item above is mainly for earth chamber.
Material and Labour for copper strip of size 20 mm x 3 mm complete including taking out the old unserviceable strip of any type, complete all as specified and as directed.
S&F as in repair ON LOAD change over switch 415V ,50 Hz 4 pole of capacity 200 Amps, complete all as specified and as directed.
Supply only 11KV HT fuse wire of 5 amp capacity
Supply only 11KV HT fuse wire of 10 amp capacity
Supply only 11KV HT fuse wire of 20 amp capacity
Supply only 11KV HT fuse wire of 30 amp capacity
M/s Rohit Construction Co.
Aman Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .