Loading…
Loading…
709 results • Best match
Please refer in BOQ
Please refer to BOQ
Please refer to BOQ
Please refer in BOQ
Please refer in BOQ
Please refer to BOQ
Please refer in BOQ
please refer BOQ
Construction of 12 Nos. RCC living cum fighting bunkers, c/o 04 nos. RCC bullet proof observation post, installation of high security bullet proof main gate along with sentry post and guard room 03 Nos. with allied security accessories, construction ... Senior Architect Unit ...
Please refer in BOQ
Please refer in BOQ
Please refer in BOQ
Please refer in BOQ
pabx system-EPABX Pabx System-EPABX ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values EXTENSION AND TRUNK/JUNCTION EPABX system Implementation Tech nology/Architecture Hybrid ( Microprocessor based also supporting SIP extension ) Conventional ( Card/microcontroller based ), Hybrid ( Microprocessor based also supporting SIP extension ), Server Based ( Switching through Call Server Application ) Number of Analogue Extensions/FXS Ports 24 As per GeM Catalogue. Expandable Upto (TDM/FSX Ports) 256 As per GeM Catalogue. Number of Digital Extensions 4 4 Number of Analogue Junction/FXO ports 4 As per GeM Catalogue. Number of SIP Extensions NA As per GeM Catalogue. SIP Extensions expandable upto NA As per GeM Catalogue. Number of SIP Trunks NA 4, 8, 16, 32, 64, 96, 128, 25 6, NA MAIN DISTRIBUTION MDF(Number of pair) 50 As per GeM Catalogue. 1/11 FRAME(MDF) Integrated Protection Module(IPM) true If YES, number of Integrated Protection Module(IPMs) 50 As per GeM Catalogue. CARDS CARDS Type of Cards Supported BRI, PRI, E1, E&M, Radio Interface, GSM BRI, GSM, NA Number of Ports per Card Supported 24 1, 2, 4, 6, 12, 24, NA GATEWAYS Type of Gateways Supported SIP, FXO, FXS, Radio, E&M - Number of Ports per Gateway Supported 24 - CONSOLE Type of Operator Console Key phone based PC based, Key phone based, Server Based, NA Number of Operator Console 1 As per GeM Catalogue. SERVER SPECIFICATIONS REQUIREMENTS Total Number of Servers Included in the Supply NA As per GeM Catalogue. "Number of Hot Standby Servers out of Total Servers, included in the Scope of Supply" 0 - Server Form Factor NA - Rack Size (RU)/Space Required for each Server NA - Processor Make NA - Processor Configuration & Description NA - Total Number of processor NA 1, 10, NA Number of Redundant Processors Included in the Total Number of Processor NA 1, NA Number of Cores per Processor NA As per GeM Catalogue. Type of RAM NA - RAM Size (in GB) NA 4, 256, N A T ype of Hard Disk Drive NA - 2/11 Capacity of Hard Disk Drive (in TB) NA As per GeM Catalogue. Hot Swap Components NA Power Supply Unit, Fans, HDD, NA Network Interface NA - SOFTWARES Applcation Software Type/Capabilities NA Call Server Software, Hot StandBy Server Software, Unified Communication Server Software, Network Management Server Software, NA Type of Licence NA Perpetual, Subscription Based, NA Name of Softwares NA - Name of the OEM NA - OEM Model/Part Number NA - Software Description NA - Software Version NA - Date of Launch of Version NA - Free supports/updates during validity of license NA - SOFTWARE FEATURES Analog Extention/FXS ( If Yes, Number of Software/Licences shall be Commensurate Equal to the Number of Analog Extension/FXS Offered under ""EXTENSION AND TRUNK/JUNCTION"" ) YES YES, NO, NA ( For Convensional PBX ) "Digital Extension ( If Yes, Number of Software/Licences shall be Commensurate Equal to the Number of Digital Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES, NA ( For Convensional PBX ) 3/11 "Analog Junction/FXO ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of Analog Junction/FXO Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES, NA ( For Convensional PBX ) "SIP extension ( If Yes, Number of Software/Licences shall be Commensurate Equal to the Number of SIP Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NO YES, NA ( For Convensional PBX ) "SIP trunk ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NO YES, NA ( For Convensional PBX ) "PRI Trunk ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of PRI Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NO YES, NA ( For Convensional PBX ) "Radio Interface ( If Yes, Number of Software/Licences shall be Commensurate Equal to the Number of Radio Interface Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NO YES, NA ( For Convensional PBX ) "GSM ( If Yes, Number of Software Licences shall be YES YES, NA ( For Convensional PBX ) 4/11 Commensurate Equal to the Number of GSM Offered under ""EXTENSION AND TRUNK JUNCTION"" )" "E1 Trunk ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of E1 Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NO YES, NA ( For Convensional PBX ) "E&M ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of E&M Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NO YES, NO GENERAL FEATURES of EPABX SYSTEM Number of Conference Participants Supported 64 8, NA Number of Direct Station Selection Keys per Console 24 - Number of Media Channel/Ports Supported 8 8, 512, NA Number of IP-TDM Concurrent Calls(2 users per call) Supported 256 As per GeM Catalogue. Call Buffer Memory System true If Call Buffer Memory Available, Number of Records 2000 100, 250, 500, 1000, 200 0, NA Hot Standby Redundant CPU false If YES, Number of Hot Standby CPU Cards 1 1, NA Hot Standby Redundant PSU (Power Supply Unit) false 5/11 If YES, Number of Hot Standby Redundant PSU Cards 1 1, NA Inbuilt Voice Mail for EPABX System true If Voice Mail Available, Number of Voice Mail Channels 4 4, NA Available for Voice Mail, Number of Hours of Recording 4 4, 5 12, NA Auto Attendant Facility true - If Available, Number of Auto Attendant Channels 4 - ASMDR/CDR true Voice Logger Inbuilt External Connecting facility Inbuilt, Inbuilt External Connecting facility, NA If YES, Number of Simultaneous Calls that can be Recorded in Voice Logger 64 - Security Feature(for server based) NA - Supported Functionalities (for server based) NA - Supported Codecs G711, G729, G723, H264, VP8 - Any other features REAL TIME FAULT DIAGNOSTING WITH AUTO SMS ALERT(OPTIONAL) - SYSTEM/EXTENSION/AT TENDANT CONSOLE FEATURES System Features Automatic Route Selection facility, DID facility(Direct inward dialing), DOD facility(Direct outward dialing), DISA facility(Direct inward station access), DOSA facility(Direct outwards station access), Multi Level Voice DISA facility, Privacy of Call, Facility for connecting recorded voice answering, ASMD R/CDR, Programmable As per GeM Catalogue. 6/11 class of service for (STD/ISD/LOCAL) dialing as per need, Caller ID information for both internal and external callers (over Analogue, ISDN PRI), unique authorization codes for every users, Automatic call back, Call waiting, Music-on-hold facility, Call budgeting, Least cost routing, Mix-mode dialing, Provision for remote logins, Interactive Voice Response System(IVRS), Extensio n to Extension dialing Extension Features Call forwarding, Consultatio n Hold, Brokers Call, Automatic call transfer, Conference call, Call pick up, Call re routing, Auto call disconnection, Dynamic STD Lock, Paging on key phone, Background music, Password control, Virtual Telephony, Howler Tone, Call parking, Auto answer/Auto off, Emergency call facili ty, Missed/Dialed/Receiv ed Call Lists, Last Caller Call back, Password display suppression, Personal Identification Number, Hotline, Preset Conference Calls, Direct Call billing in rupees, Call billing printout, Calling line ide ntification(CLI), Remote Maintenance, Other Extension features As per GeM Catalogue. Attendant Console Features Answering an incoming call, Call queuing, Serial Call, Call waiting display, Automatic Call Distribution, Call Answering an incoming call, Call 7/11 Hold, Trunk offering, Night service, Head phone connectivity, Other Attendants console Features Hold, Other Attendants console Features Voice Prompts and Announcement true - If yes, Number of Levels of IVRS 8 1, 3, 5, 7, NA POWER SOURCE Supply Voltage 230V AC, 50HZ 230V AC, 50HZ, 48V DC, NA Provision for Inbuilt Battery Charging Arrangement for providing Battery Backup NA - FCBC NA YES, minimum current Rating of FCBC at chrging voltage of 48V (Ampere) NA 10A, 12.5A, 25A, 50A, NA Protection against over current and accidental reversal of polarity on the input side and against over current, over voltage on the output side NA - OPERATING CONDITIONS Minimum Operating Temperature (Degree C) 0 10, 0, 10 Maximum Operating Temperature (Degree C) 45 35, 40, 45, 50, 55 Operating Humidity (RH) (% ) 95 80, 85, 90, 95 TEST REPORT DETAILS AND TESTS TEC approval as per the latest TEC specifications YES - TEC approval Certificate number TEC/NR/I/PBX-04/02 095 - Availability of the test report from Central Government/NABL ILAC acredited lab to prove conformity to the specification including Environmental Test true - 8/11 Sequence Test Report Number and date (not a part of biddable parameter) ERTL(N)/90(4)-(2013-14 )/C0265 - Name and Address of the Test lab(not a part of biddable parameter) - - Test reports consist of verification of all the features & functional parameters & environmental tests true - conformity to Dry Heat for 16 hours at maximum specified temperature degree C in accordance with IS:9000/part-3/sectio n-5/1977 latest true conformity to Cold Test for 4 hours at minimum specified temperature degree C in accordance with IS:9000/part-2/sectio n-4/1977 latest true conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:9000/part-5/s ection-1/1991 latest true INSTALLATION AND MAINTENANCE Installation and Commissioning With With, Without Chemical Earthing to achieve resistance 2ohm false Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System YES - OPERATION & MAINTENANCE SUPPORT The scope of supply include one set of operation and maintenance manual for each equipment YES - 9/11 Operation & Maintenance terminal Provided - Training provided to buyers true If YES, Details of training On site training for 3 days On site training for 3 days, On site training for 5 days, NA Packing List YES - SERVICES Warranty 1 1, 9, 10 Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System, YES - Compliance to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 GANGA SINGH UDAWAT 190005, O/O The DIG, SHQ (Spl. OPS), SSB Srinagar 1 15
Please refer in BOQ
Please refer in BOQ
Pabx System-EPABX ( 3 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values EXTENSION AND TRUNK/JUNCTION EPABX system Implementation Tech nology/Architecture Hybrid ( Microprocessor based also supporting SIP extension ) Conventional ( Card/microcontroller based ), Hybrid ( Microprocessor based also supporting SIP extension ), Server Based ( Switching through Call Server Application ) Number of Analogue Extensions/FXS Ports 48 48, 64, 96 (or higher) Expandable Upto (TDM/FSX Ports) 256 * Number of Digital Extensions 8 4, 8, 16, 24, 32, 128, NA Number of Analogue Junction/FXO ports 8 * Number of SIP Extensions NA * 1/11 SIP Extensions expandable upto 256 * Number of SIP Trunks NA 4, 96, 256, NA MAIN DISTRIBUTION FRAME(MDF) MDF(Number of pair) 100 * Integrated Protection Module(IPM) true true, false If YES, number of Integrated Protection Module(IPMs) 100 * CARDS CARDS Type of Cards Supported BRI, PRI, E1, E&M, Radio Interface, GSM BRI, GSM, NA Number of Ports per Card Supported 24 1, 2, 4, 6, 12, NA GATEWAYS Type of Gateways Supported Universal Gateway, SIP, FXO, FXS, Radio, E&M * Number of Ports per Gateway Supported 24 * CONSOLE Type of Operator Console Key phone based PC based, Key phone based, Server Based, NA Number of Operator Console 2 * SERVER SPECIFICATIONS REQUIREMENTS Total Number of Servers Included in the Supply NA * "Number of Hot Standby Servers out of Total Servers, included in the Scope of Supply" 0 * Server Form Factor NA * Rack Size (RU)/Space Required for each Server NA * Processor Make NA * Processor Configuration & Description NA * Total Number of processor NA 1, 10, NA Number of Redundant Processors Included in the Total Number of Processor NA 1, NA 2/11 Number of Cores per Processor NA * Type of RAM NA * RAM Size (in GB) NA 4, NA T ype of Hard Disk Drive NA * Capacity of Hard Disk Drive (in TB) NA * Hot Swap Components NA Power Supply Unit, Fans, HDD, NA Network Interface NA * SOFTWARES Applcation Software Type/Capabilities NA Call Server Software, Hot StandBy Server Software, Unified Communication Server Software, Network Management Server Software, NA Type of Licence NA Perpetual, Subscription Based, NA Name of Softwares - * Name of the OEM - * OEM Model/Part Number - * Software Description - * Software Version - * Date of Launch of Version - * Free supports/updates during validity of license NA * SOFTWARE FEATURES Analog Extention/FXS ( If Yes, Number of Software/Licences shall be Commensurate Equal to the Number of Analog Extension/FXS Offered under ""EXTENSION AND TRUNK/JUNCTION"" ) YES YES, NO, NA ( For Convensional PBX ) "Digital Extension ( If Yes, Number of Software/Licences YES YES, NA ( For Convensional PBX ) 3/11 shall be Commensurate Equal to the Number of Digital Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" "Analog Junction/FXO ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of Analog Junction/FXO Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES, NA ( For Convensional PBX ) "SIP extension ( If Yes, Number of Software/Licences shall be Commensurate Equal to the Number of SIP Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES, NA ( For Convensional PBX ) "SIP trunk ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES, NA ( For Convensional PBX ) "PRI Trunk ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of PRI Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES, NA ( For Convensional PBX ) "Radio Interface ( If Yes, Number of Software/Licences shall be Commensurate Equal to the Number of Radio Interface YES YES, NA ( For Convensional PBX ) 4/11 Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" "GSM ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of GSM Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES, NA ( For Convensional PBX ) "E1 Trunk ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of E1 Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES, NA ( For Convensional PBX ) "E&M ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of E&M Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES, NO GENERAL FEATURES of EPABX SYSTEM Number of Conference Participants Supported 64 8, NA Number of Direct Station Selection Keys per Console 24 * Number of Media Channel/Ports Supported 256 8, 512, NA Number of IP-TDM Concurrent Calls(2 users per call) Supported 8 * Call Buffer Memory System true true, false If Call Buffer Memory Available, Number of Records 2000 100, 250, 500, 1000, 2000, NA Hot Standby true true, false 5/11 Redundant CPU If YES, Number of Hot Standby CPU Cards 1 1, NA Hot Standby Redundant PSU (Power Supply Unit) true true, Number of Hot Standby Redundant PSU Cards 1 1, NA Inbuilt Voice Mail for EPABX System false true, false If Voice Mail Available, Number of Voice Mail Channels 4 4, NA Available for Voice Mail, Number of Hours of Recording 4 4, NA Auto Attendant Facility false * If Available, Number of Auto Attendant Channels 4 * ASMDR/CDR true true, false Voice Logger Inbuilt External Connecting facility Inbuilt, Inbuilt External Connecting facility, NA If YES, Number of Simultaneous Calls that can be Recorded in Voice Logger 64 * Security Feature(for server based) NA * Supported Functionalities (for server based) NA * Supported Codecs G711, G729, G723, H264, VP8 * Any other features Push Button CLI PHONE:20 Nos, REAL TIME FAULT DIAGNOSTING WITH AUTO SMS ALERT(OPTIONAL), * SYSTEM/EXTENSION/AT TENDANT CONSOLE FEATURES System Features Automatic Route Selection facility, DID facility(Direct inward dialing), DOD facility(Direct outward dialing), DISA facility(Direct inward * 6/11 station access), DOSA facility(Direct outwards station access), Multi Level Voice DISA facility, Privacy of Call, Facility for connecting recorded voice answering, ASMD R/CDR, Programmable class of service for (STD/ISD/LOCAL) dialing as per need, Caller ID information for both internal and external callers (over Analogue, ISDN PRI), unique authorization codes for every users, Automatic call back, Call waiting, Music-on-hold facility, Call budgeting, Least cost routing, Mix-mode dialing, Provision for remote logins, Interactive Voice Response System(IVRS), Extensio n to Extension dialing Extension Features Call forwarding, Consultatio n Hold, Brokers Call, Automatic call transfer, Conference call, Call pick up, Call re routing, Auto call disconnection, Dynamic STD Lock, Paging on key phone, Background music, Password control, Virtual Telephony, Howler Tone, Call parking, Auto answer/Auto off, Emergency call facili ty, Missed/Dialed/Receiv ed Call Lists, Last Caller Call back, Password display suppression, Personal Identification Number, Hotline, Preset Conference Calls, Direct Call billing in rupees, Call billing printout, Calling line ide * 7/11 ntification(CLI), Remote Maintenance, Other Extension features Attendant Console Features Answering an incoming call, Call queuing, Serial Call, Call waiting display, Automatic Call Distribution, Call Hold, Trunk offering, Night service, Head phone connectivity, Other Attendants console Features Answering an incoming call, Other Attendants console Features If yes, Number of Levels of IVRS 8 1, 3, 5, 7, NA POWER SOURCE Supply Voltage 48V DC 230V AC, 50HZ, 48V DC, NA Provision for Inbuilt Battery Charging Arrangement for providing Battery Backup NO * FCBC NO YES, minimum current Rating of FCBC at chrging voltage of 48V (Ampere) NA 10A, 12.5A, 25A, 50A, NA Protection against over current and accidental reversal of polarity on the input side and against over current, over voltage on the output side YES * OPERATING CONDITIONS Minimum Operating Temperature (Degree C) 0 10, 0, 10 Maximum Operating Temperature (Degree C) 45 35, 40, 45, 50, 55 Operating Humidity (RH) (% ) 95 80, 85, 90, 95 TEST REPORT DETAILS AND TESTS TEC approval as per the latest TEC specifications YES * TEC approval Certificate number - * Availability of the test true * 8/11 report from Central Government/NABL ILAC acredited lab to prove conformity to the specification including Environmental Test Sequence Test Report Number and date (not a part of biddable parameter) - * Name and Address of the Test lab(not a part of biddable parameter) - * Test reports consist of verification of all the features & functional parameters & environmental tests true * conformity to Dry Heat for 16 hours at maximum specified temperature degree C in accordance with IS:9000/part-3/sectio n-5/1977 latest true true, false conformity to Cold Test for 4 hours at minimum specified temperature degree C in accordance with IS:9000/part-2/sectio n-4/1977 latest true true, false conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:9000/part-5/s ection-1/1991 latest true true, false INSTALLATION AND MAINTENANCE Installation and Commissioning With With, Without Chemical Earthing to achieve resistance 2ohm false true, false Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System - * 9/11 OPERATION & MAINTENANCE SUPPORT The scope of supply include one set of operation and maintenance manual for each equipment YES * Operation & Maintenance terminal Provided * Training provided to buyers true true, Details of training On site training for 3 days On site training for 3 days, On site training for 5 days, NA Packing List - * SERVICES Warranty 1 1, 9, 10 (or higher) Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System, * Compliance to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 D. P. 180010, Chief Engineer Project Sampark BRO Kunjwani Chowk JAMMU - 180010 3 45
Please refer in BOQ
Please refer in BOQ
Please refer to BOQ
Please refer to BOQ