Loading…
Loading…
2,551 results • Best match
Thin walled e-beam irradiation flexible cable with copper conductor working voltage above 750 Volts and upto 1.8/3.0 KV, grade size 4 sq. mm as per RDSO Specn. No. ELRS/SPEC/ELC/0019 REV-4 of Feb.2018
"TOP CLAMP ASSEMBLY OF OHE DISCHARGE ROD SUITABLE FOR ROUND /STRANDED CONDUCTOR OF 10 MM TO 20 MM DIAMETER CONF. TO RDSO SPECN.NO. ETI/OHE/51(9/87) WITH A&C SLIP NO.1 & SIMILAR TO DRG.NO.POWER /RLY/43
Supply and Laying of PVC Conduit pipe size 25 mm, Supply and Laying of CAT 6 STP weather proof armoured cable, Surveillance HDD 4 TB 7200 rpm, Supply of Commercial LED 22inch, Supply and Laying of copper conductor Armoured cable, Supply and installation of 6U wall mounting Network Rack, Supply and Installation of SS weather proof junction boxes, Supply and installation of 8 channel rack mounted NVR, Supply of Full HD Internet Protocol, Supply and Installation of Rack mounted 10 port GbE Fast and Smart Managed PoE Switch, Installation testing and Commissioning of IP Based CCTV surveillance, Supply and Laying of 12 core Armored Fiber cable single mode, Trenching on Hard surface, Trenching on soft surface with 3 ft. depth, Rack Mounted Fully Loaded LIU Box, Supply of Online UPS 1 KVA min
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days Bid Number : GEM/2025/B/6333806 Dated : 11-06-2025 Bid Document 1/7 ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) Yes Inspection to be carried out by Buyers own empanelled agency Yes Type Of Inspection Pre Dispatch Name of the Empanelled Inspection Agency/Authority RITES Estimated Bid Value 2311974 Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Advisory Bank State Bank of India EMD Amount 46240 ePBG Detail Required No (a). EMD EXEMPTION: The bidder seeking EMD exemption, must submit the valid supporting document for the relevant category as per GeM GTC with the bid. Under MSE category, only manufacturers for goods and Service Providers for Services are eligible for exemption from EMD. Traders are excluded from the purview of this Policy. (b)., EMD & Performance securityshould be in favour of Beneficiary, wherever it is applicable. Beneficiary : AFA/JUDW Northern Railway, Indian Railways, Northern Railway, Ministry of Railways (Arun Miglani) Splitting
Augmentation of existing 132kV double Bus Bar of 132kV s/stn HSIIDC Bawal from single ACSR Zebra conductor to Twin ACSR Zebra conductor.
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, ... criterion. XLPE Cable For ... for XLPE cable as ... of Conductor (in ... of conductor Aluminium ... Aluminium Conductor material ... the conductor Stranded ... cable Armoured cable Material ... - XLPE Cable For ...
Supply, erection and testing of GI pipe, Submersible Copper Cable 3 Core 4Sqmm, Electric Control Penal, Motorpumps, Development of tubewell and Gravel Packing for smoothly running of water supply during summer season
AMtc of EPHS in Sector 7 UE Ambala City Earthing for transformer at STP and 40 HP panel board submersible copper cable complete in all respect and all other works contingent thereto
Estimate for Replacement of Damaged HT AB Cable 395 Sqmm unwinding with HT XLPE 3c95mm2 on 11 KV line STP Independent feeder fed from 66 KV SStation Sohna under OP Sub Division Sohna During the year 202122
Rewinding of 150 HP Induction Motor Copper wire 150 Sqm mm Single core Polycab MCCB 400 Amp. Triple pole and related water supply assets at Water Works Sec 8 Panchkula and all other allied works contingent thereto
DIGITAL MONITOR, CHANGE OVER SW, BATTERY, WOODEN SW, SMALL CARPET, SMALL PLASTIC TRAY, MILTON CAMPER 12LTR, LARGE TOWEL, HBF224 BODY COMPOSITION, BODY FAT ANALYZER, COPPER WIRE, BULB 23WATT, FLEXI WIRE ROLL, DIGITAL CLOCK BOQ Title BOQ BID
Appointment of IBBI Registered Valuer for Creation of LILO of both circuits of 220KV Double Ckt Jind Kirori line at 220KV Substation Petwar with 0 4 Sq inch ACSR Zebra Conductor on Multy Ckt Towers approx length 16 49 Km
Converting single bus to double bus bar(twin conductor) and by extending 132kV Bus to accomodate 132kV Bus copuler, 132kV line bay and creation of line bay for 132kV line from Deroli Ahir at 132 KV S/Stn. Ateli Mandi.
Converting single bus to double bus bar(twin conductor) and by extending 132kV Bus from B-5 to B-7 to accomodate 132kV Bus copuler and line bay from Seka to 132kV Nangal Choudhary line at 132kV s/stn Nangal Choudhary.
Top clamp Assembly of OHE Discharge Rod suitable for round / stranded conductor of 10 mm to 20 mm Diameter conf. to RDSO Specn. No. ETI/OHE/51 (9/87) with A&C slip No. 1 & similar to Drg. No. Power/RL
ONE COACH SET OF DETAIL ITEMS FOR CONDUCTOR BERTH OF LACCW COACHES (REF. DRG. No.LWSCWAC/EOG-6-1-016, ALT-a, ITEMS - 2, 3, 6, 7, 8, 9 & 11) CONSISTS OF: 1)CHAIN ASSEMBLY, LWSCWAC/EOG-6-1-020, ALT-c,
Providing fixing of 3 Nos. Horizontal Motor pumping set, aluminum 16 Sq. mm, 25 Sq. mm armoured cable for existing Main Boosting Station Nizampur Road, SBS No. 1 2 Goad, Khatoti Kalan, Bhankhri for running the water supply smoothly and all other
Augmentation of 66kV Twin ACSR Zebra conductor with Twin Tarantula AAC conductor on 66kv Double Bus-bar arrangement at 220kV S/Stn HVPNL Daultabad
Schilka Outlet Pressure Pipe, Spanner 6 to 32 Tool Kit, Screw Driver set, Heavy Duty Electric Wire Cutter, Tank Painting Machine, Insulated Gloves11000W, Hydrometer, Brass Terminal, Heavy Duty Painting Hose Pipe, Gun Drill Boot
L2 MANAGEMENT SWITCH, MODULE SINGLE FIBER, OTE SFP MODULE, OPTICAL TO EITHER NET, RJ CONNECTOR, IO BOX, OFC 6 CORE, FIBER BOX, 4U RACK, EITHER NET CABLE, CONDUIT PIPE, BATTON, ELECTRIC WIRE, MULTI BOARD
LED Batten with Battery/Invertor (Q3), XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2), PTMT Tap Fitting (Q3), Flushing Cistern (Q3), Toilet Seat Covers (V2) (Q4)
A Mtc of STP Dharuhera Supply and erection of 11 KV HT PT and and 11 KV HT CT 95sqmm HT XLPE cable 3 core, heat sprinkable jointing kit complete with all accessories at STP Dharuhera
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, ... criterion. XLPE Cable For ... for XLPE cable as ... of Conductor (in ... of conductor Aluminium ... the conductor Stranded ... cable Armoured cable Material ... - XLPE Cable For ...
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, ... criterion. XLPE Cable For ... for XLPE cable as ... of Conductor (in ... of conductor Aluminium ... the conductor Stranded ... cable Armoured cable Material ... - XLPE Cable For ...
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, ... criterion. XLPE Cable For ... for XLPE cable as ... of Conductor (in ... of conductor Aluminium ... the conductor Stranded ... cable Armoured cable Material ... - XLPE Cable For ...
AMtc of EPHS in Sector 10 UE Ambala City Supply of cables and power factor correction capacitors water works complete in all respect and all other works contingent thereto
Replacement of faulty main service cable and related works for all Quarters back side in GPO Ambala Cantt HR
Work of Supply erection commissioning and testing of 300 sq mm 3 core Armored Aluminum HT cable at 11 KVA feeder Nuna majra in Urban Estate Bahadurgarh and all other work contingent thereto
led street light 90w, led post top luminaires aluminium diecast base 45w, led recess mounting panel light 36 w 2x2, led post top luminaires aluminium diecast base 20w, PVC 3 point 5 core x 120 sqmm aluminium armoured, led street light 60w, led flood ... Aluminium armoured Cable , ... Aluminium conductor cable, ... Aluminium conductor cable, ... 100amp, Pvc insulated cable ... 40amp, Pvc insulated cable ... copper conductor 2 ... aluminium conductor 2 ... sqmm, Pvc insulated cable ... copper conductor 4 ... sheathed copper cable conductor 2core ... 6Amp, Pvc insulated Tapes ...
Jhumpa kalan Loharu AMtc Water supply scheme Jhumpa Kalan Group of 41 Nos Nos Villages Loharu Rewinding of 350 BHP submersible pump set No1 including cost of F class insulation material copper wire mechanical seal upper and lowe
CA NO CWE/CHM(U)-34/2021-22 SPL REPAIR/ REPLACEMENT OF LT PANEL, BER TRANSFORMERS, CONVERSION OF OH CONDUCTOR TO UG CABLE AND ALLIED WORK AT WCCSR AND CHANDIMANDIR MIL STN AND AUGMENTATION OF POWER SUPPLY AT DEPENDENT AREA OF SUB STN NO 7
Supply , Erection, Testing ,Commissioning of LT cable and all other works contingent items and Installation, Testing ,Commissioning of new LED Lights of various watt at Zone 3 Under Municipal Corporation Gurugram.
Supply , Erection, Testing ,Commissioning of LT cable and all other works contingent items and Installation, Testing ,Commissioning of new LED Lights of various watt at Zone 4 Under Municipal Corporation Gurugram
Erection of GI pole,Street light fitting and Supply and erection of LT cable other contingent item there on at Hero Honda road to Central Park road under limit of MCG.
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No Document required from seller Past Performance, Certificate (Requested in ATC), OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 3, -- Number of days for which Bid would be auto -- extended 3 Bid Number : GEM/2025/B/7032638 Dated : 24-12-2025 Bid Document 1/10 Number of Auto Extension count 1 Past Performance 20 % Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) Yes Inspection to be carried out by Buyers own empanelled agency Yes Type Of Inspection Pre Dispatch Name of the Empanelled Inspection Agency/Authority RITES Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Advisory Bank State Bank of India EMD Amount 81250 ePBG Detail Advisory Bank State Bank of India (%) ePBG Percentage(%) 5.00 ( ) Duration of ePBG required (Months). 32 (a). EMD EXEMPTION: The bidder seeking EMD exemption, must submit the valid supporting document for the relevant category as per GeM GTC with the bid. Under MSE category, only manufacturers for goods and Service Providers for Services are eligible for exemption from EMD. Traders are excluded from the purview of this Policy. 2/10 (b)., EMD & Performance securityshould be in favour of Beneficiary, wherever it is applicable. Beneficiary : Sr.DFM/UMB Northern Railway, DRM Office, Ambala Cantt (Rakesh Kumar)
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, ... criterion. XLPE Cable For ... for XLPE cable as ... of Conductor (in ... of conductor Aluminium ... the conductor Stranded ... cable Armoured cable Material ...
10Sqm 2core Alluminium, 200Amp Bus Bar Connection Box, 32A DP MCB, 2 point 5mm 2core copper cable, 100Amp 4pole MCCB, MCCB Encloer, Insulation Tape, 70mm 4core Alluminium Cable, 4core 35mm Aluminium Cable, Alluminium Thimbles
Soft Board with Aluminium Beading 2ft x 2.5ft, Soft Board with Aluminium Beading 2ft x 1.5ft, Plywood 8ft x 4ft, Fevicol SR 998, Drawer Channel 16 inch, 2.5MM Copper Wire, 6MM Copper Wire, IFF Light, Crocodile Clip, Water Proof HDPE Shelter Cloth, Inch Tape 5 Mtr, Bosch Hand Grinder, 2 Inch Screw Driver, Capacitor 200W to 250W, Toggle Switch, Rexine Black, 2 Inch Foam sheet 6ft x 4ft, 1 Inch Angle Iron, 1 Inch Iron Patti, 2 Inch Wooden Fatta 7ft x 8 ft
Annual maintenance of 15 MLD STP Zone-III Dabra Hisar. Providing and fixing of HT cable joint MCCB in panel board including all accessories and copper lugs etc. and all other works contingent thereto
Supply and joint Armoured cable 120 sqmm at TW Ashiana Colony repair of 150 to 200 HP Immersed Starter at WW Sec 20 and Subm cable MCCB and contractor Block MNX TW KV 7 KV 4 KV 12 KV 9 KV 8 Sec 20 Panchkula
augmentation of existing 66 kV double bus bar having single ACSR Zebra conductor with twin ACSR Zebra conductor at 66 kV substation Harsaru under TS Manesar
1.Repairing of damaged conductor at 220kV Madanpur-Tepla and Madanpur-Raiwali transmission line in jurisdiction of AE TL Madanpur. 2.Providing tack welding on 62 nos. towers in 220kV D-C Pinjore-Baddi-Kunihar line during FY 2021-22. 3.Providing and
Laying, testing and commissioning of 66 KV 4x1Cx1200 Sq. mm armoured Aluminium conductor Milliken type underground cable on one circuit of under construction 66 KV DC line from 220 KV Sec-58 Faridabad to 66 KV Bhagola between TL No. 56 to 57.
REPAIR REPLACEMENT OF HT LT U G CABLE LT PANELS ELECTRICAL APPLIANCES AT SUB STN TRANSFORMER UPTO 2 MVA CONTROL SWITCH GEAR LIGHTENING CONDUCTOR EARTHING SECURITY LIGHT AND CONNECTED ITEMS AT AF STN INDUAR UNDER AGE E M RAJOKRI UNDER GE AF GURGAON
GE(W)/HSR-32/2021-22 PROVN OF PUMPING SET FOR RAW WATER AND CLEAR WATER RESERVOIR AT FILTERATION PLANT AND LIGHTING CONDUCTOR WITH EARTHING AND CONNECTED WORK FOR OXYGEN GENERATION PLANT SHED AT MH AT HISAR MIL STN UNDER GE (WEST) HISAR
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, ... criterion. XLPE Cable For ... for XLPE cable as ... of Conductor (in ... of conductor Aluminium ... the conductor Stranded ... cable Armoured cable Material ...
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, ... criterion. XLPE Cable For ... for XLPE cable as ... of Conductor (in ... of conductor Aluminium ... the conductor Stranded ... cable Armoured cable Material ...
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No Document required from seller Past Performance, Certificate (Requested in ATC), OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 3, -- Number of days for which Bid would be auto -- extended 3 Bid Number : GEM/2025/B/7032920 Dated : 24-12-2025 Bid Document 1/10 Number of Auto Extension count 1 Past Performance 20 % Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) Yes Inspection to be carried out by Buyers own empanelled agency Yes Type Of Inspection Pre Dispatch Name of the Empanelled Inspection Agency/Authority RITES Estimated Bid Value 2110728 Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Advisory Bank State Bank of India EMD Amount 42210 ePBG Detail Advisory Bank State Bank of India (%) ePBG Percentage(%) 5.00 ( ) Duration of ePBG required (Months). 32 (a). EMD EXEMPTION: The bidder seeking EMD exemption, must submit the valid supporting document for the relevant category as per GeM GTC with the bid. Under MSE category, only manufacturers for goods and Service Providers for Services are eligible for exemption from EMD. Traders are excluded from the purview of this 2/10 Policy. (b)., EMD & Performance securityshould be in favour of Beneficiary, wherever it is applicable. Beneficiary : Sr.DFM/UMB Northern Railway, DRM Office, Ambala Cantt (Rakesh Kumar)
Estimate for providing additional Infrastructure including HT / LT lines HT XLPE Cable additional distribution transformers of Various capacity at various location in builder area of Sushant Lok 1 for improvement of LD System under SDO Sushant lok su
AMtc of EPHS in Sector 5 UE Kurukshetra Supply of Power factor correction capacitors Copper cable sluice valve NRV and Panel Board in various tubewell complete in all respect and all other works contingent thereto