Loading…
Loading…
5,587 results • Best match
Repairing, restoration re-erection of 11KV- 433V 1000KVA Dry-type Transformer by replacing of burnt out one HV LV coil and servicing of HT Panel at Falakata SSH, District Alipurduar on emergency basis.
D.O. Barrel Complete set, 30 mm with Top & Bottom attachment (Both made of hard brass) for 25KV/240 V Auxiliary Transformer as per RDSO specification No: ETI/PSI/14(1/86) Rev-1.
CONST OF CC ROAD FROM TRANSFORMER TO CHANTA PUKUR IN BOOTH 257 AT VILLAGE DAKSHIN DURGAPUR JL NO 92 Scheme ID-APAS/01/179/257/0005 under Radhapur Gram Panchayat under APAS FUND
Construction of road from Bilmadhia PMGSY Transformer to Jhaljhali Primary School via Tapan Maity house in Nilda GP within Mohanpur Panchayat Samity area in the District of Paschim Medinipur. (under Rural road 2025)
Construction of Transformer plinth, VCB, CT, Cable box support structure, Cable trench, Circular loop and other allied work at Baishnabnagar 33/11 kV sub-station under Malda Division, in the district of Malda
Gr. K Construction of new high drain starting from ujjwal sutradhar house to kali mandir and asha ganguly to suman mazumder at transformer goli within ward no-18 under purulia municipality.(168/3,4)
Supply and Installation of stabilizer, APFC, replacement of transformer, highmast light and other ancillary EI works at Dankuni Dairy plant under Banglar Dairy Limited, LB 2, Sector III, Salt Lake City, Kolkata 700106
25 kv POTENTIAL TRANSFORMER TYPE 1,core type ,single phase out door installation, immersed self cooled, available for mounting, structural steel support (PT RATIO 27.5 KV/100V) as per RDSO SPEC NO. ti
Circuit Breaker 3 pole for TM Blower and Oil cooling unit Transformer/converter along with Auxiliary contact (2 No Type) as per CLW Spec. no. CLW/ES/3/0096 (Alt.-L) (63 AMP)
Circuit Breaker 3 pole for TM Blower and Oil cooling unit Transformer/converter along with Auxiliary contact (2 No Type) as per CLW Spec. no. CLW/ES/3/0096 (Alt.-L) (63 AMP).
Circuit Breaker 3 pole for TM Blower and Oil cooling unit Transformer/converter along with Auxiliary contact (2 No Type) as per CLW Spec. no. CLW/ES/3/0096 (Alt.-L) (63 AMP)
Radiator Blower Motor with Impeller and Impeller Fittings of Powder Drivers for 1300 KVA EMU Transformer Fitted in Medha Rake as per High Volt Electricals Pvt. Ltd. Part No. E130050020, Spec. KW -0.37
Self Gripping sealing Rubber gasket (1no=09Mtrs) as per Drg. No- 1209-18.406-089 Alt-5 with latest Alteration for Transformer Sealing Section. Specification :- Drg No-1209-18.406-089 Alt-5 with latest
Pressure Sensor 0-4 bar for Transformer of WAG-9 with accessories {Cable, washer and cannon connectors (Plug and Plug Socket)}. Cable must be connected with Plug socket connector to concerning pin wit
Pressure Sensor 0-4 bar for Transformer of WAG-9 with accessories (Cable, washer and cannon connectors {Plug and Plug Socket}). Cable must be connected with Plug socket connector to concerning pin wit
OIL LEVEL INDICATOR OF TRANSFORMER FOR THREE PHASE LOCOMOTIVES AS PER ABB DRAWING NO/DOCUMENT NO-HSTN 420277P0015 OR LATEST. MAKE: SUKRUT. MATERIAL TO BE SUPPLIED AS PER DRG AND SPECIFICATIONS. DRG A
Set of Gasket for transformer bushing & accessories consisting 05 items as per ASN's Drg. No. :- E5/01/A/ER, Sheet (1) & (2). Detailed specification as per annexure enclosed. Offer of Firm : Make/Bran
Pressure sensor 0-4 bar for transformer of WAG-9 with accessories (Cable, washer and cannon connectors {Plug and Plug Socket}). Cable must be connected with Plug socket connector to concerning pin wit
SUSPENSION BOLT COMPLETE FOR BHEL EMU TRANSFORMER COMPRISING OF: (A)HEX. BOLT M 22x2.5x110 WITH PROVISION OF SPLIT PIN HOLE. (B) CASTLE NUT M 22x2.5. (C) SPRING WASHER M22A (FORBS GOKAK MAKE). SPECIFI
Oil Cooler radiator 165 KW for main transformer 5400 KVA for WAG-7 locomotive CLW drg. no.CLW/ES/SK-1/0-4/E as per Drg.No. CLW/ES/SK-1/0-4/E.
TRANSFORMER FOR CAB FAN (TFVT) 220V/110V, SINGLE PHASE, 50 HZ, 300 VA CONFORMING TO CLW SPECN NO. CLW/ES/T- 29. SUITABLE FOR CLW BUILT ELECTRIC LOCOMOTIVE. Firm's offer /Make Brand - E.E.I.CORPORATION
RELAY, PLUG IN TYPE, STYLE "AC-LED" ALL ASPECTS, AC LAMP PROVING RELAY UNIT WITH IN- BUILT CURRENT TRANSFORMER TYPE, SLOW RELEASE NEUTRAL LINE RELAY, 4F, 4B, CONTACTS, FRONT AND BACK CONTACTS, METAL
25 KVA, 25KV/240V, Single Phase, Oil filled Auxiliary transformer as per RDSO Specification No. ETI/PSI/15(08/2003) or latest along with all accessories. Accepted Offer: Make/brand - M/s.ARU TRANSFORM
Transformer module primary voltage (Pos no 224.2) as per CLW spec No CLW/ES/3/0083 Alt- B and ABB Document no- 3EHP590547R0001 . CLW Drg No- CLW/ES/3/SK1/0083 Alt-B
SET OF NITRILE RUBBER VULCANIZED BUTADIENE AND HYDROGENATED NITRILE BUTADIENE GASKET FOR BUSHING OF 3-PHASE TRANSFORMER TYPE LOTT 6500/7500. AS PER SKETCH NO. ELW/BSL/3-PH/SK.NO.305 ALT-1
PALM CLAMP FOR a0,a1 BUSHING (20-MM STUD DIA) OF THE CONVENTIONAL LOCO TRANSFORMER AS PER C.RLY. DRG.NO. ELW/BSL/2/F.91.043 ALT-1 ITEM SL.NO.11. Firm's offer: OWN Make.
Auxiliary transformer 415V/110V (Pos no 67) 15KVA/1000V-415/110V ABB Document No- 3EHP590064R0015 or latest as per CLW Spec no CLW/ES/3/0098 (or) latest. FIRM'S OFFER MAKE/BRAND : SELF
Transformer module primary voltage (Pos no 224.2) as per CLW spec No CLW/ES/3/0083 Alt- B and ABB Document no- 3EHP590547R0001. CLW Drg No- CLW/ES/3/SK1/0083 Alt-B.
Anti Vibration Mounting Pad (AVM) for 60 KVA transformer of LHB AC coaches confirming to RDSO Specification No.-RDSO/PE/SPEC/AC/0080- 2007 (Rev-2) or latest. Accepted Make RESISTOFLEX, DUNLOP, mettali
110 KV OUTDOOR OIL FILLED CURRENT TRANSFORMER OF RATIO 400-200/5A AS PER RDSO SPEC. NO. TI/SPC/PSI/CT/0210(07/2021) OR LATEST WITH TERMINAL CONNECTOR. ACCEPTED MAKE/BRAND : LAMCO
Description of store :- -TFILM cost resin type current transformer 250/5A, SPS-20 VA.. Spec./Drg. No. :- CLW Spec. No. CLW/ES/T-27 with latest Alt. Make/Brand-MBCOM POWERTECH PVT LTD.
Current Transformer 25 KV, 3000-1500/5A, PS class 2 Core with accessories as per RDSO Specification No. TI/SPC/PSI/CT/0210 (07- 2021). Make brand-CORE Approved Sources. Make :- LAMCO MAKE
Transformer Oil Testing Kit - Determination of Acidity of TFP oil Consisting of 06(six) items as follows: (i)Polythene Bottle containing 100 ml Alcohol(or neutral rectified spirit). Qty/set: 01 no. (i
RELAY, PLUG IN TYPE, STYLE "AC-LED" ALL ASPECTS, AC LAMP PROVING RELAY UNIT WITH IN- BUILT CURRENT TRANSFORMER TYPE, SLOW RELEASE NEUTRAL LINE RELAY, 4F, 4B, CONTACTS, FRONT AND BACK CONTACTS, METAL
Indoor type 250 KVA transformer, 3-phase, 11KV/0.433 KV, 50 Hz,oil immerged, CRGO, ONAN with all standard fitting & accessories. Detail Specifications are as per PCEE's Spec.No.PCEE-139(R-2)/2017 with
Thermostat with capillary tube for use pro BHEL EMU transformer. As per M/S.Indfoss Model No.RT-101(3M) Or its equivalent with bulb pocket connection size 1/2 Inch BSD(M).Make-INDFOS.
10KVA, 25 KV/240V, 50 HZ single phase Oil filled Auxiliary Transformer for Railway AC traction system as per RDSO Specification No.ETI/PSI/15 (08/2003) along with all fittings. Firms Offer: SSTPL.
Set of Nitrile rubber vulcanized butadiene and hydrogenated nitrile butadiene rubber gasket for main transformer bushing for WAG-9 and WAP-7 (3 Phase) class of locomotives comprising of 06 items in 62
Air blast transformer oil cooler (Radiator) with blower motor for BHEL EMUs to ICF Spec.No.ICF/ELEC/014 Rev.A with Annexure 'B' Correction Slip CS-01 & ICF Drg.No.ICF/SK-9-0-606 Alt.'e'.
25 KV Current Transformer oil filled, CT Ratio- 3000-1500/5 Amp as per RDSO%u2019s Spec: TI/SPC/PSI/CT/ 0210/07-2021, STR: CORE-STR-08, Make- CORE/RDSO approved manufacturer.
High Voltage HRC Fuse (Bolted type) 32 Amps, 3.3/3.6 KV AC, confirming to RDSO spec no. RDSO/PE/SPEC/AC/0158-2010, Rev-1, Suitable for 15 KVA Transformer in LHB coaches.
CORK COMPOSITION SHEET ( MEDIUM GRANULAR CORK ) TYPE- C, GRADE- RC.50C, SIZE-610 MM X910MM X 10MM TO IS:4253. PT.-II/1980 FOR FIXING OF TRANSFORMER BUSHING Firm's offer accepted make/brand:ATC.
132 KV Current Transformer oil filled, CT Ratio- 400-200/5 Amp as per RDSO%u2019s Spec: TI/SPC/PSI/CT/ 0210/07-2021, STR: CORE-STR-08, Make- CORE/RDSO approved manufacturer.
TRANSFORMER FOR CAB FAN (TFVT) 220V/110V,SINGLE PHASE,50 HZ,300 VA CONFORMING TO CLW SPECN NO.CLW/ES/T-29. SUITABLE FOR CLW BUILT ELECTRIC LOCOATIVE . ACCEPTED-M/s. OM ENTERPRISE/Kolkata.
Supply of VF and signaling transformer used for derivation and termination of underground cable circuit with impedance ratio 470:600 ohm/ohm as per RDSO Specification IRS TC-22/2021. Ver1.1 or lates
TRANSFORMER FOR CAB FAN (TFVT) 220V / 110V, SINGLE PHASE, 50 HZ, 300 VA CONFORMING TO CLW SPECN.No. CLW/ES/T-29 SUITABLE FOR CLW BUILT ELECTRIC LOCOMOTIVE. Firm's Offer: Make/ Brand - OWN. Transforme
Nitrile Bonded Rubber Cork Sheet Type RC 70C Very Good oil resistance for Main Transformer Thickness 3mm of Size 900x600mm to IS Specn 4253/Part II -2008 (Second Revision) Firm's offer: Max make
100 VA STEP DOWN TRANSFORMER 750/110 V AC H-CLASS INSULATION SUITABLE FOR LHB NON AC COACHES, CONFIRMING TO RCF SPEC. NO. EDTS-355 REV. 1 AMNDT. 2 Accepted Make/Brand: self
Auxiliary transformer 451V/110V (POS NO.67) 15KVA/1000V - 415/110V. ABB Document No.- 3EHP 590064R0015 as per CLW Spec. No.- CLW/ES/3/0098(ALT.-B). MAKE BRAND- MBCOM POWERTECH PVT LTD
FLEXIBLE EXPANSION PIECE FOR AC EMU TRANSFORMER TO BHEL DRG. NO.146619500013 REV.00 ST 601895 FIG.2, 2.5 INCHES. Note: One sample to be supplied and got approved , Unloading by consignee. Make:CE