Loading…
Loading…
909 results • Best match
SITC of Online Inverter in EE, MID Office Hut Bay, Little Andaman under EandM Division APWD, Prothrapur
Providing electrical wiring for connection of solar hybrid inverter output power at the Police Out Post, Bakultala.
Providing electrical wiring for connection of solar hybrid inverter output at the office of the PRO, Rangat.
Providing electrical wiring for connection of solar hybrid inverter output power to Police Booth, Passa,Car Nicobar.
Layer two manageable twenty four port switch with one thousand base RJ forty five SFP, One KVA UPS with Battery Bank, Twelve U wall mounted rack, Cat six UTP cable, I O box, Capping cashing cat six cable, Twenty four RJ forty five patch panel, Installation charges
Providing sub main wiring for connection of solar panel inverter output power to desired load for ANIIMS Buildings
Providing sub main wiring for connection of solar panel inverter output power to desired load for Secretariat Buildings
Supplying, installation, testing and commissioning of 02 Nos. Inverter type Air Conditioner to server room at PS Rangat.
Providing sub main wiring for connection of solar panel inverter output power to desired load for ANIIDCO Buildings
Supplying and fixing of Inverter 3.5 KVA and Battery 150 Ah to Chief Judicial Magistrate at Lucknow, Mayabunder.
SITC of 02 Nos 1.5 Ton Inverter Split Type Air Conditioner at Server Room of Police Station Bambooflat
Providing submain wiring for connection of solar hybrid inverter output power to desired load at Passenger Hall, Baratang.
Providing submain wiring for connection of solar hybrid inverter output power to desired load at Police Station, Baratang.
Providing electrical wiring for connection of solar hybrid inverter output power at the Office of the SDPO, Rangat.
Providing electrical wiring for connection of solar hybrid inverter output power at the Fire Station, Rangat and Bakultala.
Supply, Installation, Testing and Commissioning of Inverter for Solar Power Plant at North point Light House, Port Blair Directorate
lead acid battery Average Turn Over of Last 3 Years 5 Lakh (s) Experience with Gov. Required 1 Year (s) Lead Acid Battery ( 64 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Fibre Reinforced Plastics (FRP) Fibre Reinforced Plastics (FRP) Rated Capacity at C20 discharge (AH) 180 180 Warranty (Years) 2 Years 1 Year, 2 Years Battery Condition Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 18000 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn., Yes. - 1/3 corresponding Ah No.of cells per Battery (No.) 6 Cells for 12 Volt battery - CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab RANCHI - Name of the Lab SUN-TECH - Test Report No. ST/TR/20 - Test Report Date 10-03-2018 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells, and for Batteries made from them for use in portable applications YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 K Nagendra Rao 744101, O/o The Police Marine Force Marine Hill, Marine Jetty P.O., Port Blair 64 15
SITC of 02 Nos 2 Ton Inverter Split Type Air Conditioner in the CCTV Server Room of PS Ograbraj
Providing sub main wiring for connection of solar panel inverter output power to desired load for Education Department Buildings
Providing sub main wiring for connection of solar panel inverter output power to desired load for Tagore College Buildings
SITC of 02 Nos 1.5 Ton Inverter Split Type Air Conditioner in the CCTV Server Room of PS Humprigunj
Providing sub main wiring for connection of solar panel inverter output power to desired load for Police Department Buildings
Providing sub main wiring for connection of solar panel inverter output power to desired load for Industries Department Buildings
Providing sub main wiring for connection of solar panel inverter output power to desired load for Disaster Management Buildings.
Supplying, installation, testing and commissioning of 01 No. Inverter type split Air Conditioner in the office of SDPO Rangat.
Providing sub main wiring for connection of solar panel inverter output power to desired load for JNRM College Buildings
Providing sub main wiring for connection of solar panel inverter output power to desired load for Revenue Department Buildings
Providing sub main wiring for connection of solar panel inverter output power to desired load for Electricity Department Buildings
Supplying, Installation, testing and commissioning of 2500VA inverter including wiring in the office room of PM shri GSSS Swadeshnagar
Providing Sub Main Wiring for connection of solar panel inverter output power to desired load for Passenger Hall, Mayabunder.
Construction of Regional Center Building for IGNOU, Port Blair including water supply, sanitary installation, drainage, strom water drains & providing internal electrical installation, DG set, Lift, Fire Alaram, System and Fire Extinguiser etc SH: ... 5 KVA UPS and ...
Television supply and installation, Mixer Grinder, Double Door Refrigerator, Toaster With Electronic Sensor, Induction Stove, Electric Iron Box, Electric Kettle, Water Purifier Supply and Installation, Split air conditioner Supply installation and ... Heater, Inverter Supply ... Installation, Lead Acid Battery , ... Installation, Inverter battery ...
SITC of 02 Nos 2 Ton Inverter Split Type Air Conditioner in the CCTV Server Room of PS Shaheed Dweep
SITC of 02 Nos 02 Ton Inverter Split Type Air Conditioner in the CCTV Server Room of PS Pahargaon Terlorabad
Providing submain wiring for connection of solar panel inverter output power to desired load for Directorate of Agriculture Department Buildings
Providing sub main wiring for connection of solar panel inverter output power to desired load for Andaman Law College Buildings
Providing sub main wiring for connection of solar panel inverter output power to desired load for Labour Commission, Department Buildings
Replacement of old window Air conditioner with Inverter high wall split unit in room no 101A at Secretariat Port Blair
SITC of 02 Nos 1.5 Ton Inverter Split Type Air Conditioner in the CCTV Server Room of PS Swaraj Dweep
Desktop Computers (Q2), Online UPS (V2) (Q2), Line Interactive UPS with AVR (V2) (Q2)
Emergency procurement of critical products/services. Battery 12 V 100AH, SMF, Battery Lead, User Manual, Rubber Mat 0.125 Thickness, Installation And Commisioning
Providing sub main wiring for connection of solar panel inverter output power to desired load for Port Management Board Departments Buildings
Replacement of old Air conditioners with inverter high wall units in DD Health Office under DHS near Youth Hostel, Port Blair
SITC of 1.1 KVA Inverter with accessories to the Consumer Grievances Redressal Forum under Electricity Department, Horticulture Road, Haddo, Port Blair
Providing sub main wiring for connection of solar panel inverter output power to desired load for Directorate of Transport Department Buildings
Providing sub main wiring for connection of solar panel inverter output power to desired load for Directorate of Health Services Buildings
Providing sub main wiring for connection of solar panel inverter output power to desired load for Account and Budget Department Buildings.
Providing sub main wiring for connection of solar panel inverter output power to desired load for Education Department Buildings 9 Buildings
Providing sub main wiring for connection of solar panel inverter output power to desired load for Revenue Department Buildings.4 Buildings
Providing Sub Main Wiring for connection of Solar Panel inverter output power desired load for DC Office Buildings at Lucknow, Mayabunder