Loading…
Loading…
514 results • Best match
LG Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, LG Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
LLOYD Cooling Only 1 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, LLOYD Cooling Only 1 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
Endoscope, Colonoscope, Online UPS, ICU bed partition, Few Civil works
Battery Secondary Lead Acid MT Type (Defence) (Q2), Stationary Lead Acid Batteries (with Tubular Positive Plates) in Monobloc Containers as per IS 13369 (Q3), Lead Acid starter Batteries (Q3) (3 (3 ))
Molded Case Circuit Breakers (MCCB), miniature circuit breakers, Nylon Rubber Sheet, dusk to dawn controller- Sensitive switch, lead acid battery Bidder Turnover (Last 3 Years) 6 Lakh (s)
Digital white board, PVC wall Panel, CCTV System, Online UPS, Monitor
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2)
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2)
High End Desktop Computer (Q2), Computer Monitor (Q2), Online UPS (V2) (Q2)
Multimedia Projector (MMP) (Q2), Online UPS (V2) (Q2), Multifunction Machines MFM (Q2)
High End Desktop Computer (Q2), Online UPS (V2) (Q2), Multifunction Machines MFM (Q2)
Server (Q2), Online UPS (V2) (Q2), Entry and Mid Level Desktop Computer (Q2)
High End Desktop Computer (Q2), Multimedia Projector (MMP) (Q2), Online UPS (V2) (Q2)
Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz Backup time (Minutes) 120 120 Minimum VAH (VAH) 16000 16000 Warranty for UPS (Years) 2 2 Movable trolly for Batteries With With Warranty for battery 2 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising With With, Without Installation and Commissioning Yes - 1/4 CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 Yes - 2/4 (reaffirmed 2007) at 55 degree C for 16 hrs Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. UQ-8326 - Type Test Certificate date 08-10-2016 - Name of Lab UKCERTIFICATIONS (ROHS) - Address of Lab NEW DELHI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Binay Kumar Swain 790003, GSO1 INFO SYSTEMS HQ 5 Mtn Div C/o 99 APO PIN 908405 1 15
Lead Acid Storage Batteries for Motor Vehicles as per IS 7372 (Q3), Lead Acid starter Batteries (Q3), Lead Acid Batteries for Motor Vehicles with Light Weight and High Cranking Performance as per IS 14257:2019 (Q3)
lead acid battery Lead Acid Battery ( 50 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 180 180 Warranty (Years) 2 Years 2 Years Battery Condition Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 15000 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn., corresponding Ah Yes. - No.of cells per Battery (No.) 6 Cells for 12 Volt battery - 1/3 CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab Thirupati - Name of the Lab ARBL - Test Report No. TS/AAE/05/14-15 - Test Report Date 22/12/2014 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells, and for Batteries made from them for use in portable applications yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Pradeep Kumar Gaikwad 790101, Chief Engineer HQ Chief Engineer Project Vartak C/o 99 Apo 50 60
lead acid battery Lead Acid Battery ( 35 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 100 100 Warranty (Years) 2 Years 2 Years Battery Condition Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 6300 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn., corresponding Ah Yes. - No.of cells per Battery (No.) 6 Cells for 12 Volt battery - 1/3 CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab HALDIA - Name of the Lab EXIDE - Test Report No. EIL/100 - Test Report Date 2018 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells, and for Batteries made from them for use in portable applications AS PER OEM - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Pradeep Kumar Gaikwad 790101, Chief Engineer HQ Chief Engineer Project Vartak C/o 99 Apo 35 60
lead acid battery Lead Acid Battery ( 30 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 88 88 Warranty (Years) 2 Years 2 Years Battery Condition Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 6.3 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn., corresponding Ah Yes. - No.of cells per Battery (No.) 6 Cells for 12 Volt battery - 1/3 CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab J C NAGAR, BANGALORE - Name of the Lab DGQA - Test Report No. CQAL/0023/L1301543F 2013 - Test Report Date 27/04/2016 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells, and for Batteries made from them for use in portable applications YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Pradeep Kumar Gaikwad 790101, Chief Engineer HQ Chief Engineer Project Vartak C/o 99 Apo 30 60
Bankbook or Passbook Update Machines - Printer (Q3), Online UPS (V2) (Q2), Desktop Computers (Q2)
UPS 1 KVA, KEYBOARD MOUSE COMBO, UPS BATTERY, PRESSURE ROLLER, TEFLON SLEEVE
High End Desktop Computer (Q2), Online UPS (V2) (Q2), Network Attached Storage (NAS) Device (Q4)
Supply along with ICT (Installation, Commissioning & Testing) of 200 kVA UPS with Batteries
Core Switch, 48 Port Switch, 24 Port Switch, Stacking or DAC Cable, 10GBASE LR SMF transceiver, 10GBASE SR MMF transceiver, Wireless Controller, Indoor Wireless Access point, outdoor Wireless Access point, NMS with required hardware, 2 nos 20 KVA ... KVA online UPS , ... UPS, Batteries for ... 20 KVA UPS with ... Mount Online UPS , ... UPS, Batteries for ... 1 KVA UPS with ... Mount Online UPS , ... UPS, Batteries for ... 3 KVA UPS with ...
MTEK UPS 1000VA, KEYBOARD MOUSE WIRELESS HP, KEYBOARD MOUSE HP WIRED, KEYBOARD MOUSE HP POWER PACK WIRED, KEYBOARD MOUSE ZEBRONICS WIRED, LEAD ACID BATTERY INTEX 12V 7AH, DVD WRITER, MOTHER BOARD GIGABYTE H410 MS2V2, SMPS IBALL ZEBRONICS, PRESSURE ... EXIDE UPS BATTERY , ...
High End Desktop Computer (Q2), Online UPS (V2) (Q2), Video Conferencing Camera/Web Camera (V2) (Q2)
All in One PC (Q2), Online UPS (V2) (Q2), Line Interactive UPS with AVR (V2) (Q2)
Entry and Mid Level Desktop Computer (Q2), Multifunction Machine MFM (V2) (Q2), Online UPS (V2) (Q2)
High End Desktop Computer (Q2), Online UPS (V2) (Q2), Multifunction Machines MFM (Q2), Scanner (V2) (Q2)
Inverter (V2) (Q2), Entry and Mid Level Desktop Computer (Q2), Portable Water Purifiers or Filters (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller ... category Inverter (V2) ...
85 Inch Interactive panel with OPS and inbuilt camera and mic, 75 Inch Interactive panel with OPS and inbuilt camera and mic, OPS, Floor Panel Stand, 3 KVA Online UPS, 26 AH Battery for Online UPS, Wireless Collar Mic
ADN PC, BIOMETRIC ACCESS CONTROL SET, splitter, scanner, Video Confrence Set, STANDLONE PC, Online UPS, switcher, Visualizer
Server, High End Desktop Computer, Workstation, Online UPS (V2), EQUIPMENT ENCLOSURES, DATA REPOSITORY SYSTEM, NETWORK LINKAGE DEVICE
All in One PC (Q2), Online UPS (V2) (Q2), Thin Client Computers (V2) (Q2), Computer Printers (Q2)
Interactive Panels with CPU (Q2), Television (TV) (V2) (Q2), High End Desktop Computer (Q2), Online UPS (V2) (Q2)
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2), Multifunction Machine MFM (V2) (Q2) (3 (3 ))
Electronic Lectern (Q2), Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2), Multimedia Projector (MMP) (Q2)
All in One PC, Desktop Computers, Computer Printers, Online UPS Bidder Turnover (Last 3 Years) 8 Lakh (s)
mother board, processor i5, keyboard with mouse, ups battery 12v 7ah, ups 1kva, monitor 19inch, roller
All in One PC (V2) (Q2), Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2) (3 (3 ))
Dehumidifier 12 Ltrs, Luminous Inverter 900VA, Luminous Inverter battery 200Ah, Luminous Inverter trolley, Airport luggage trolley
Monitor, Key Board and Mouse Combo, Motherboard 610, Motherboard 310, UPS Battery, Fuser Unit Kyocera, Logic Card
High End Desktop Computer (Q2), Online UPS (?10 KVA) With Battery Conforming To IS 16242 (Part 1) (Q2) (3 (3 ))
High End Desktop Computer (Q2), Online UPS (?10 KVA) With Battery Conforming To IS 16242 (Part 1) (Q2) (3 (3 ))
High End Desktop Computer (Q2), Online UPS (?10 KVA) With Battery Conforming To IS 16242 (Part 1) (Q2) (3 (3 ))
High End Desktop Computer (Q2), Online UPS (?10 KVA) With Battery Conforming To IS 16242 (Part 1) (Q2) (3 (3 ))
All in One PC (Q2), Professional Large Format Display (Q2), Line Interactive UPS with AVR (V2) (Q2), Online UPS (V2) (Q2)
Line Interactive UPS with AVR (V2) (Q2), Online UPS (V2) (Q2), Multimedia Projector (MMP) (Q2), Entry and Mid Level Desktop Computer (Q2)
Computer Printer (V2) (Q2), Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2), Multifunction Machine MFM (V2) (Q2) (3 (3 ))
Entry and Mid Level Desktop Computer (Q2), Online UPS (? 10 KVA) With Battery Conforming To IS 16242 (Part 1) (Q2) (3 (3 ))
Entry and Mid Level Desktop Computer (Q2), Online UPS (? 10 KVA) With Battery Conforming To IS 16242 (Part 1) (Q2) (3 (3 ))