Loading…
Loading…
4,543 results • Best match
Online UPS (V2) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Past Performance, Bidder Turnover, Certificate (Requested in ATC), OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 1 Bid Number : GEM/2025/B/6395902 Dated : 29-06-2025 Bid Document 1/7 Past Performance 40 % Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Online UPS (V2) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Past Performance, Bidder Turnover, Certificate (Requested in ATC), OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 2 Bid Number : GEM/2025/B/6425729 Dated : 07-07-2025 Bid Document 1/7 Past Performance 40 % Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Online UPS Average Turn Over of Last 3 Years 15 Lakh (s) Experience with Gov. Required 5 Year (s) Online UPS ( 3 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 10.0 KVA 10.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 16000 16000 Warranty for UPS (Years) 2 2 Movable trolly for Batteries Without trollery but with rack Without trollery but with rack Warranty for battery 2 2 Degree of Protection IP20 IP20 Cabling 5 meters for input and out put With With Paralleling kit for synchronising Without Without 1/5 Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with Yes - 2/5 IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. QVC/CE/ROHS/2015-16 045 - Type Test Certificate date 15/12/2015 - Name of Lab QVC - Address of Lab Ambala - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rakesh Kumar 191101, Sector HQ Srinagar, ITB Police, Zeven Camp, Panthachowk, Srinagar 3 15
Ups online 10kva, Battery for ups, Battery rag, Battery connector, Racks for battery, Installation and fittings charges
Anti virus total security (Q3), HP 78/A TONNER (Q3), INK SET EPSON (Q3), UPS BATTERY (Q3)
UPS 1 KVA, Wired Computer Mouse, Battery 12 Volt 7 AH or UPS Battery, Wired Computer Keyboard
VGA cable 1 Mtr, Maint box L8050, Processor cooling fan i5 processor, Printer USB cable 5 Mtr, Printer USB cable 3 Mtr, Microtek online UPS 1 KVA with 03 Bty 12V 26AH, Microtek online UPS 2 KVA with 06 x Bty 12V 26AH each, CMOS battery
please refer BOQ
LOGIC CARD FOR UPS, EPSON PROJECTOR BULB, BULB FOR VIEW SONIC PROJECTOR, UPS 1 KVA, UPS BTY
8 PORT POE SWITCH, CCTV CAMERA, UPS 600 KVA, UPS BTY 12V 7 AH, RJ 45 CONNECTOR
OPTICAL FIBRE CABLE, 8 PORT SWITCH, 9 U RACK, 1 KVA UPS, WIFI ROUTER DUAL MODE, OTE
TFT monitor 24 INCH, UPA 1 KVA, UPS BTY, OPC DRUM, CLEANING BLADE, PRESSURE ROLLER, KEYBOARD MOUSE
Supply, Installation, Testing and Commissioning of 1.5 Ton Hot and Cold Split Type AC (inverter series) along with other necessary accessories for Divisional and Sub-Divisional Office.
Providing and fixing of 1.50 tone energy efficient whirlpool make inverter split air conditioner including providing and fitting of voltage stabilizer at division Office cum computer room.
BTY 12V 7AH, SMPS 24 PIN, KEYBOARD AND MOUSE COMBO, POWER SUPPLY ONLINE UPS, RAM 8GB DDR IV FURY DESK
Projector Lamp, power supply card photo copy machine, Online UPS Main Board, Projector Main Board, Printer Power supply main board
All in One PC (V2) (Q2), Multifunction Machine MFM (V2) (Q2), Interactive Panels with CPU (Q2), Online UPS (V2) (Q2)
Computer Printers (Q2), Interactive Panels with CPU (Q2), Desktop Computers (Q2), All in One PC (Q2), Online UPS (V2) (Q2)
Canon Image Class MF-275DW, HP Laser Jet 1108 Plus, Online UPS 1KVA, PC Power Cable, Epson Printer Power able
QUICK BATTERY CHARGER, BLAZER TABLE CLOTH WITH 5GR CREST, ONLINE UPS 1KVA, FLOOR MATTING OFFICE, DUCKBACK GUM BOOTS, HAND GLOVES
All in One PC, Online Ups-IS:9000, interactive panels and accessories Bidder Turnover (Last 3 Years) 64 Lakh (s)
All in One PC, Online Ups-IS:9000, interactive panels and accessories Bidder Turnover (Last 3 Years) 17 Lakh (s)
High End Desktop Computer (Q2), Online UPS (?10 KVA) With Battery Conforming To IS 16242 (Part 1) (Q2) (3 (3 ))
Supply Installation testing and commissioning of various items for delina Grid station
Ups, Inverter, Battery, Inverter trolly, Copier trolly, Installation inverter, All in one pc, Printer, photostat, Automatic voltage transformer
Exide solar inverter, Luminous Inverter, Havells Motors, Cromption motors, Pipe
C/o 1000 seat hi-Tech Auditorium at NIT Srinagar J and K SH Balance work of internal electrical installation fire fighting system fire Alarm system HVAC system UPS system CCTV system Audio/Video system stage lighting Acoustic furniture and external development in auditorium hall
Online UPS (V2) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Past Performance, Bidder Turnover, Certificate (Requested in ATC), OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 1 Bid Number : GEM/2025/B/6509829 Dated : 29-07-2025 Bid Document 1/7 Past Performance 50 % Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Supply, Installation, testing and Commissioning of 1.5 Ton 5 star rating inverter type ACs ( 2Nos) allied works for Technical and Accounts Section of Direction office of MHED Kashmir.
Supply installation testing and commissioning of hot and cold inverter technology based high wall mounted split air conditioning units in New Cath Lab Department of Cardiology SKIMS Soura
Supply, Installation, Testing and Commissioning of Inverter Type Hot and Cold (Reversible ACs) for various sections of Skill Centre (to be established) at AMT School of GMC, Srinagar
UPS BATTERY 12V 7AH, UPS 1 KVA, MOTHER BOARD I5 13TH GEN, LED MONITOR, SMPS, KEYBOARD AND MOUSE
Bosch Drill Machine, UPS Battery 1 KVA, Curtain Hook, Curtain Rod 12 Feet, Plastic Tarpaulin 30 by 30
UPS 1KVA, UPS Battery 12V 7.2 AH, Epson Printer Head, Canon Printer Head, Laser unit HP 1020 Printer
UPS BATTERY 12V 7AH, UPS 1KVA, PAPER PICKUP ROLLER, LED MONITOR, GEAR ASSY, UPS 650VA, KEYBOARD AND MOUSE
QGIS Server, Analysis Server, High End Desktop, Touch Screen Display, Layer 2 Switch 16 port, 42U Rack, 5 KVA Online UPS
Slide presenter, High End Desktop Computer, Online UPS (? 10 KVA) With Battery Conforming To IS 16242 (Part 1), video conference speaker
PHOTOCOPY MACHINE DRUM, CLANING BLADE PHOTOCOPY MACHINE, ONLINE UPS 5 KVA CHARGING CARD, SCR RECTIFIER CARD, TRANSFORMER 12 V MULTI BINDING
Thermowave 1 LTR, Weight Machine, Soldering Machine, Online UPS 1KVA MICRO T, Battery 12v 26ah EXDI, Anchor Wire 1point5 MM 90mtr
All in One PC mid range (Q3), Online UPS 2KVA with 2 hours backup (Q3), Laser Printer (Q3), Web Cam (Q3)
All in One PC (V2) (Q2), Online UPS (?10 KVA) With Battery Conforming To IS 16242 (Part 1) (Q2) (3 (3 ))
i7 12th Gen 16GB Ram 1 TB SSD, Inbuilt Window 11 Pro with 21.5 TFT, 1 KVA UPS
DMD CARD, RAM DDR 8GB, PROCESSOR I5, MOTHER BOARD H-110, UPS 1 KVA, UPS BTY 12V 7AH
STABLIZER 30 KVA, UPS REPAIR, HDD 2TB, UTP CAT6 CABLE, HP 12A, TONER TN 2365 BOQ Title TTIE01
Keyboard Mouse, UPS 1 KVA, UPS bty, RAM DDR 8 GB, Pressure Roller, Internal Hard Drive 4 TB
Repair of Washing point, Repair of office inverter luminous, Repair of Elect inverter luminous, Wiring reqd to replace in inverter, 40 Amp fuse reqd to replace in inverter
INVERTER 100 AH, BATTERY, TFT 21 INCH, POWER CABLE, INVERTER FUSE
Key Board Mouse wireless, Key board with wire, Inverter with bty 220 Ah, Inverter with bty 160 Ah, Inverter 850W
Providing and fitting of 24v inverter with batteries and other allied works to be carried out at office of the Superintending Engineer Jal Shakti (PHE) Deptt. Mech. Circle (North).