Loading…
Loading…
3,792 results • Best match
Installing tubeset FanPower Point, LAN Point Ac Servicing,UPS servicing 62.5 KV DG Servicing in old court complex and installing AC light Fan Earthing , new 5KVA UPS Battery in Lokayukt SP Office in belagavi city for financial year 2025-26
Annual Maintenance & Repairs of Electrical works & Electrical fixtures to Staff Quarters B2 Block (Ground to Fourth Floor), UPS Batteries, RO System with allied Electrical accessories to R1, R2 & R3 in the premises of High Court Bench Kalaburagi for the year 2024-25. (Work Reserved for CAT-1)
Operation and maintenance of various E & M services including IEI, Sub station equipment, water supply pump sets, DG set, Passenger & Goods Lift at CISF 10th RB, Dabaspet, Bengaluru for the year 2024-25. SH: Replacement of damaged UPS batteries, pump set in STP, street light cable.
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2)
Desktop Computers (Q2), Online UPS (V2) (Q2), Television (TV) (V2) (Q2)
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2)
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2)
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2)
Supply of 24 V 300 Ah Traction battery (Q3), Supply of 12 V 7 Ah SMF battery (Q3)
Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT-PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 15, 30, 60, 90, 120, 180, 2 40 Minimum VAH (VAH) 12480 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 Movable trolly for Batteries Without With, Without, Without trollery but with rack 1/4 Warranty for battery 2 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with Yes - 2/4 IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. Will provide if required - Type Test Certificate date Will provide if required - Name of Lab Will provide if required - Address of Lab Will provide if required - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Amit Gupta 560063, AIR FORCE STATION YELAHANKA 1 15 EMD Required No ePBG 3/4 Required No
Custom Bid for Services - TOTAL LUMPSUM AMOUNT INCLUDING ALL CHARGES AND GST FOR 2 YEARS FOR REPAIR AND MAINTENANCE OF VERTIV MAKE 2 X 20 KVA UPS ON QUARTERLY BASIS NOTE 1 LS EQUAL TO 8 QUARTERLY Similar Category Support Services
DC Regulated Power Supply, Rechargeable Sealed Maintenance Free (SMF) Lead Acid Battery, Power SB50 Connector Kit 50 Amps, red Housing, w/6 AWG contact AWG contract, 6331G1 (1Pair) (Anderso
Supply Installation Testing and Commissioning of 1.5 TR and 2 TR Highwall Inverter Split AC at Various SBUs
BLOWER INVERTER ABB MAKE to Medha Part No. SP696901010 or ABB Part No. ACS150-01E-09A8-2 only.
Annual Repairs and Maintenance of Electrical Installations and Allied Systems at Mangala Council Hall, MCC Central Office, Sub Offices, and Commissioner Bungalow under Mangaluru City Corporation, including LED and Fan Fittings, Sound System, ... System, UPS Systems .
Workstation (Q2), Plotter Printers (Q2), Multifunction Machines MFM (Q2), Online UPS (Q3)
All in One PC (Q2), Online UPS (V2) (Q2), Computer Printers (Q2)
Annual Maintenance of Electrical Installation, Lighting Fixtures, LT Distribution Panels, UPS System, Street lights the PWD Annexe Building, Annexe Extension Building, KR Circle Building, Bangalore for the year 2025-26 (CAT-I)
Providing Annual Maintenance to the Electrical Installations, UPS System, Air Conditioners & LAN System in the premises of Mayo Hall Main Court Building and BBMP Court Building, Mayo Hall Complex, MG Road, Bangalore
Custom Bid for Services - Refurbishing, Swapping & Testing of SMF lead acid Batteries various ratings at ARDC-HAL for 2 years Similar Category Repair and Overhauling Service Repair, Maintenance and Installation of Plant Systems/Equipments
SUPPLY OF BATTERY OPERATED 40 VOLT CORDLESS IMPACT TORQUE WRENCH 4000 NM 1" ALONG WITH 41MM TWO Nos. SOCKETS WITH EACH MACHINE. Accepted Make/Brand:- ALICATES AL-25-4000-40V
Custom Bid for Services - MRPL Tender No 3420000060 and Service code 1055987 Load test and maintenance battery bank containing 85 to 100 cells As per tender document section and in GEM overall total lump sum rate to be quoted considering 19 each ... maintenance battery bank containing ... maintenance battery bank containing ...
Split AC of 1.5 Tr. Inverter type technology of copper coil 5 star as per IS: 1391 or latest.
Inverter suitable for vertical fuel pump motor (low rating)(0.75HP) to DLW part no. 17454633, EMD part no. 40122943.
Inverter with sine wave output Inverter With Sine Wave Output ( 3 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Inverter Governing specification Generally conforming to ... minimum Inverter shall ... * Inverter Efficiency ... The inverters shall ... * Inverter shall ...
Supply of 240V AC, 1.5KVA Inverters as per attached Technical specifications, Installation & Commissioning of the Inverters including removal & shifting of the existing inverters, Type testing/EMC qualification charges, Seismic test charges, IV & V ... of Inverter used ...
Online UPS Online UPS ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT- PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 240 240 1/4 Minimum VAH (VAH) 32000 400-640000 Warranty for UPS (Years) 2 3, 2 Movable trolly for Batteries With With, Without, Without trollery but with rack Warranty for battery 2 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With Paralleling kit for synchronising With With, Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) /= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes * Indicators for mains Yes * 2/4 presence, Battery charging and discharging, Output Over Load, Low Battery Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 J. Jeeva 583119, NMDC LIMITED DIOM, DONIMALAI PO BELLARY DIST KARNATAKA 2 30 3/4 STATE
52421105, SR1, SR2, 5242100009, 5242100019, SR3, SR4
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2) (3 (3 ))
Interactive Panels with CPU (Q2), Micro PC (MPC) (Q2), Online UPS (V2) (Q2)
High End Desktop Computer (Q2), Multifunction Machines MFM (Q2), Online UPS (V2) (Q2)
1300076361 NI-CD BATTERY BANK97 KPH 57 P, 1300049995 NI-CD BATTERY BANK 176 KPM 200P, 1300076362 NI-CD BATTERY BANK 87 KPM 105 P, 1029378 DEPUTATION SERVICE ENGINEER
Supply of Battery Operated Chamfering Machine as per RDSO SPECIFICATION no. TM/SM/336 (Rev 01 of 2023) with latest amendments. Make: ALLIANCE, Chakradhar Industries LLP, ALICATES. or similar Make :- A
Laying at LTUG cable ,AC Repairs and other Maintainance Work & Installation at UPS system Lakkundi circuit House and Electrical Maintaince at Mundargi court building Premises in Gadag Tq For the year of 2025-26
SUPPLY OF BATTERY OPERATED HYDRAULIC CRIMPING TOOL ALONG WITH DIE SET WITH FOLLOWING SPECIFICATIONS: 1) CRIMPING SIZE: 16-400 SQ.MM, 2) CRIMPING FORCE: MINIMUM 120 KN, 3) STROKE WIDTH: 42 MM, 4)
Interactive Panels with CPU (Q2), All in One PC (Q2), Online UPS (V2) (Q2)
Customized AMC/CMC for Pre-owned Products - CAMC FOR COSMIC MAKE 15KVA UPS SYSTEM FOR A PERIOD OF TWO YEARS; COSMIC MAKE 15KVA UPS; Comprehensive Maintenance Contract (CMC); AS PER TENDER DOCUMENT; No; 2 Year
Provision of 2 x 200 KVA Online Uninterrupted power supply (UPS) System for Ground Lighting Facilities at Belagavi Airport. SH- SITC of LT panel, supply and laying LT Cables and allied works at Belagavi Airport.
SUPPLY, INSTALLATION, TESTING, COMMISSIONING & PROVING OF 03 PHASE, 5 KVA ONLINE UPS WITH BATTAERIES (Q3)
High End Laptop - Notebook (Q2), All in One PC (V2) (Q2), Online UPS (V2) (Q2)
Micro PC (MPC) (Q2), Laptop - Notebook (Q2), Multimedia Projector (MMP) (Q2), Online UPS (V2) (Q2)
Annual Maintenance of Various E & M Services such as online UPS DG Set STPs and Passenger and goods lift etc. at CISF 10th RB Dabaspet Bengaluru for the year 2023-24.SH:-Repair and B-check of 62.5KVA DG set,Repairs to 100KLD STP, testing and commissioning of existing firefighting system etc.
272 Litre, Frost free double door Refrigerator, smart inverter compressor, convertible, smart diagnosis, shiny steel finish . Similar to Model No.LG GL-S312SPZX272
1 Ton Split AC : 1 Ton Capacity 3 star rated inverter split air conditioner with suitable stand. Accepted offer: Make/brand - Voltas
Online UPS Online UPS ( 4 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA 2.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 240 240 Minimum VAH (VAH) 14400 400-640000 Warranty for UPS (Years) 2 2, 3 Movable trolly for Batteries Without trollery but with rack With, Without, Without trollery but 1/4 with rack Warranty for battery 2 2 Degree of Protection IP20 IP21, IP20 Cabling 5 meters for input and out put With With Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) /= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes * Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes * REPORTS AND Damp Heat : in Yes * 2/4 CERTIFICATION accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 J. Jeeva 583119, NMDC LIMITED DIOM, DONIMALAI PO BELLARY DIST KARNATAKA STATE 4 30
UPS 1, UPS 2, UPS 3, UPS 4, CAMC 1, CAMC 2, CAMC 3
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2), Study or Laptop Table (Q3)
Plastic Moulded Chair as per IS 13713 (V2) (Q3), Desktop Computers (Q2), Online UPS (V2) (Q2)
Supply Installation Testing and Commissioning of 3 TR Cassette Inverter Type ACs along with accessories for NCS SBU BEL Bangalore as per tender
Supply Installation Testing and Commissioning along with accessories of 1 point 5TR Highwall Inverter type Split AC for D type quarters BEL Bangalore