Loading…
Loading…
6,220 results • Best match
Unbranded Welding Machine Portable Inverter type Brand: NA (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687764755719 dt.03/03/2024)
Unbranded Welding Machine Portable Inverter type Brand: NA (Detailed Description/Specification as per Product # 2 of GeM Contract No. GEMC-511687766637966 dt.04/01/2024)
AIMWELD Welding Machine Portable Inverter type Brand: AIMWELD (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687700861804 dt.17/01/2024)
ADDN/ALTN TO EXISTING BAGGAGE ROOM AT NSB, REP OF 60 KVA UPS AT TS MAHUL, PROVN OF MARKING OF UG CABLE THANE, SPL REPAIRS TO FLOORING AND DRAINAGE OF GP VI AT CSD MAZGAON, SPL REP TO NP-5,NP-6 AND NP-7 AT HQ 31 WEU UNDER GE (NW) MANKHURD
Online UPS (V2) (Q2) MSE Exemption for Years Of Experience Yes Startup Exemption for Years Of Experience Yes Document required from seller Experience Criteria, Certificate (Requested in ATC), OEM Authorization Certificate, Additional Doc 1 (Requested in ATC), Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer Do you want to show documents uploaded by bidders to all bidders participated in bid? No Bid to RA enabled No Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 7 Days Inspection Required (By Empanelled Inspection Authority/Agencies pre- registered with GeM) No Bid Number ( ) : GEM/2024/B/5680202 Dated : 23-12-2024 Bid Document 1/6 Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No MII Purchase Preference MII Purchase Preference No MSE Purchase Preference MSE Purchase Preference Yes 1. If the bidder is a Micro or Small Enterprise as per latest definitions under MSME rules, the bidder shall be exempted from the requirement of "Bidder Turnover" criteria and "Experience Criteria" subject to meeting of quality and technical specifications. If the bidder is OEM of the offered products, it would be exempted from the "
Online UPS Average Turn Over of Last 3 Years 5 Lakh (s) Experience with Gov. Required 3 Year (s) Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA 2.0 KVA Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT-PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 120 Minimum VAH (VAH) 4800 Warranty for UPS 2 1, 2, 3, 4, 5 1/4 (Years) Movable trolly for Batteries Without With, Without, Without trollery but with rack Warranty for battery 1 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With Paralleling kit for synchronising With With, Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Yes - 2/4 Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. R-410J5563 - Type Test Certificate date 08-11-20 17 - Name of Lab Bureau of Indian Standards - Address of Lab Manak Bhavan, 9 Bahadur shah Zafar Marg, New Delhi-110002 - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sachin Bhalchandra Kondhawale 415001, General Administration Department, Zilla Parishad 1 15 3/4 Satara, Satara-Koregaon Road, Sadar Bazar Camp.Satara EMD Required No ePBG Required No
Air Conditioner Air Conditioner ( 5 ) Technical Specifications Specification Specification Name Values Allowed Values CAPACITY/GENERIC Type of Air conditioner High wall Split AC High wall Split AC Technology of AC Non- Inverter (Fixed Speed) Inverter ... Non- Inverter (Fixed ... non- inverter split ... non- inverter split ...
Revolving Chair, Executive Table, Computer Table, Stainless Steel Dining Table With Fixed Chair, Deep freezer, Chairs-Office- IS 3499, Steel Filing Cabinets, Almirah Steel-IS:3312, STEEL BODY EVAPORATIVE COOLERS- DESERT COOLER, Inverter with sine ... Stationary Lead Acid Batteries (with ...
Supply, Installation, Testing and Commissioning of 1 set of Battery Bank consisting of 110 Nos. SMF V
Supply, Installation and commissioning of 110 Volts, 425 AH Plante Type Battery Bank consisting of 5 (Q3)
Multifunction Printer, Scanners, Barcode Printers, Barcode Scanner, 1 KVA UPS, DG Set BOQ Title BOQ bid
Fixed Computer Workstation (Q2), Online UPS (?10 KVA) With Battery Conforming To IS 16242 (Part 1) (Q2) (3 (3 ))
Providing replacement of online UPS to higher capacity 15 KVA in the Meeting Hall at Council Hall Pune 1
Black Ink Cartrdige, Color Ink Cartrdige, Invertor with battery, Computer, MFP Printer, Laptop, Online UPS BOQ Title BOQ BID
Photocopier Machine, A4 Colour Laser Printer, Pedastal Trolley, Network Rack 32U, UPS with built in battery 600VA, Online UPS
Online UPS (V2) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 2 Bid to RA enabled Yes RA Qualification Rule H1-Highest Priced Bid Elimination Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days Bid Number : GEM/2025/B/6544768 Dated : 08-08-2025 Bid Document 1/7 ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Providing Electrical installation LAN, Telephone, CCTV system and inverter to newly constructed first floor office building of Executive Engineer, Project Construction Division, Yavatmal at Dist. Yavatmal.
Repairing of lights at Basaveshwar statue, Chhatrapati Shivaji Maharaj statue, Dr.Babasaheb Ambedkar statue in Miraj city and installation of inverter battery in Miraj Deputy Commissioners Office.
providing Repairing and Maintenance of EI Work, APFC Panel, Geyser, Inverter, ACB/RMU, Transformer sub station, solar system, Himast and fountains at YCM Hospital (2023-24)
Est.No.1225/2020-2021 Providing Borewell Pump,Ex.Fan,Inverter and focous light in newely constructed Workshop Building at I.T.I.premises at Parbhani Dist Parbhani (for COVID-19)
Submerged Arc Welding Plant (TRACTOR MOUNTED) IGBT INVERTER BASED (1200 Amp.), with concomitant accessories, consumables, foundation, installation and commissioning with AMC of two years. Make MOGRA
Battery Charger - Nasik designed to Siemens Ordering No. 100777605 for M/s. Siemens make 180 kVA Static Inverter. FIRM'S OFFER :-MAKE/BRAND:- SIEMENS HSN CODE :- 85044090
WARPP ENGINEERS RECTIFIER INVERTER BASED (IGTB) DOUBLE BRIDGE TYPE WELDING SET 415V THREE PHASE WITH TRAPPING TO COMPENSATE FOR VARIATION IN INPUT SUPPLY , BRAND - WARPP ENGINEERS
Supply, Installation, Testing & Commissioning of 2 x 30 KVA & 2 x 10 KVA Modular Uninterrupted Power Supply (UPS) system including allied work at Reserve Bank of India, Office Premises, Nariman Bhavan & 7th floor MTNL, Mumbai (Date of NIT available: July 02, 2024)
Structural Repairs and Renovations of Directorate of Revenue Intelligence, Mumbai Zone Unit Office Building including Internal and Electrical Installations, Fire Alarm System, Lift, UPS System, EPABX and LAN etc. at Sir Vithaldas Thackersay Marg Opposite Patkar Hall, New Marine Lines, Mumbai-20.
Online UPS (V2) (Q2) MSE Exemption for Years Of Experience Yes Startup Exemption for Years Of Experience Yes Document required from seller Experience Criteria, Certificate (Requested in ATC), OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes Bid to RA enabled No Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days Inspection Required (By Empanelled Inspection Authority/Agencies pre- registered with GeM) No Bid Number ( ) : GEM/2025/B/6124133 Dated : 25-04-2025 Bid Document 1/7 Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Advisory Bank State Bank of India ePBG Percentage(%) (%) 2.00 Duration of ePBG required (Months) ( ) . 61 (a). EMD & Performance security should be in favour of Beneficiary, wherever it is applicable., Beneficiary : Director State Unit Maharashtra Pune, NA, Geological Survey of India (GSI), Ministry of Mines (Director Gsi Pune) MII Purchase Preference MII Purchase Preference Yes MSE Purchase Preference MSE Purchase Preference Yes 1. If the bidder is a Micro or Small Enterprise as per latest definitions under MSME rules, the bidder shall be exempted from the requirement of "Bidder Turnover" criteria and "Experience Criteria" subject to meeting of quality and technical specifications. If the bidder is OEM of the offered products, it would be exempted from the "
Online UPS (V2) (Q2) MSE Exemption for Years Of Experience and Turnover Yes | Complete Startup Exemption for Years Of Experience and Turnover Yes | Complete -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 3 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Bid Number : GEM/2025/B/6574123 Dated : 18-08-2025 Bid Document 1/9 Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Online UPS Average Turn Over of Last 3 Years 5 Lakh (s) Experience with Gov. Required 3 Year (s) Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 10.0 KVA 10.0kva Technology IGBT-PWM with inbuilt isolation transformer igbt-pwmwithinbuiltisol ationtransformer Input Power single phase 160V - 260V sinewave, 50Hz singlephase160v-260vs inewave50hz Output power Single phase 230V +/-1% sinewave 50 Hz singlephase230v-1sine wave50hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 16000 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 Movable trolly for Batteries Without trollery but with rack withouttrollerybutwithr ack Warranty for battery 2 2 Degree of Protection IP20 ip21, ip20 Cabling 5 meters for input and out put With with Paralleling kit for synchronising Without without 1/4 Installation and Commissioning Yes N/A CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 N/A Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) N/A FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 N/A Voltage Regulation from no load to full load (%) /= 3% N/A 20% Overload limit for minimum 10 minutes Yes N/A Overall Efficiency (%) >/=90% N/A Total Harmonic Distortion(THD) (%) Maximum 3% N/A 50% Overload limit for minimum 1 minutes Yes N/A PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes N/A Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes N/A METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes N/A Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes N/A REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes N/A Dry Heat Test : in accordance with Yes N/A 2/4 IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes N/A Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes N/A Type Test Certificate No. EQP/G0144/0800/2015 N/A Type Test Certificate date 19-02-15 N/A Name of Lab EQDC N/A Address of Lab Gandhinagar, Gujrat N/A As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Maruti Baburao 411007, Rajbhavan Complex, Baner Road, YASHADA, Pune 1 15 EMD Required No ePBG Required No
TRANSVERSE CARRIAGE NATURE, SWING ARM, TRAVELLING CRANE AFT SIDE, TRAVELLING CRANE FORWARD SIDE, SLING FOR LIFTING, ASSEMBLY JIG, DOCUMENTATION FOR BATTERY LOADING GEAR ASSEMBLY, CARRIAGE WHEEL SPARES, ROPE PULLEY SPARES, ROPE WITH HOLDING SHACKLE SPARES, TROLLEY CRANE ROLLERS SPARES, WARM GEAR AND PINION SET SPARES, DRUM PULLEY FOR HOLDING ROPE SPARES, O RING SPARES, OIL SEAL SPARES
125 V, 195 Ah Battery Bank, consists of 99 nos. of Ni-Cd cells of nominal voltage 1.2 Volt/Cell (Q3), 390 V, 154 Ah Battery Bank, consists of 277 nos. of NI-CD Cells of nominal voltage 1.2 Volt/Cell (Q3)
UPS, BATTERY, OFC, PATTI, PIPE, OTB, CONNECTOR, CABLE, ADAPTER, SWITCH, WIRE, RACK, CLIPS, SWITCHES, PATTY, DUCTING, EXCAVATION
N Type Male Connector, Stabilizer 1 KVA Ups, GPS Antenna, B Plug Regulator, Transformer 0 to 12V
office used printer machine, computer used 1 kva, Ups 1 kva, 2 in 1 switch, d link
RAESD/OW/154/2025-26 Providing highmst street light with solar panel, Ceilling fan, Inverter Tube and Bracket Fan at Rural Hospital Murud, Tal-Murud, Dist-Raigad
Supply of portable inverter type plasma cutting machine and welding machine along with allied spares and portable compressor required for trunk main maintenance under AEOC(TM) division.
Supply, Installation and Commissioning Branded Window Type Air Conditioners Non-Inverter of 1.5TR-5 Star Rating and 2.0TR -3 Star Rating capacity at premises of the Undertaking.
Supply, Installation & Commissioning of Indigenous IGBT (Inverter) based MIG/MAG welding rectifier. Make: ESAB (BUDDY MIG 500i) or similar. HSN code85153990 (Technical specification as per Annexure A
Supply of 1.5 TR. capacity SPLIT AC as specification 1) Type of AIR CONDITIONER = HIGH WALL SPLIT AC. 2) Technology of AC= INVERTER ( variable speed)= 1.5 TON
Inverter Based MIG MAG Synergic Welding Plant, Air Cooled Torch, 400 Amps with concomitant Accessories and consumables as per Technical specification and special conditions enclosed. make: KEMPPI
Provision of New/Replacement of conventional AC units with energy efficient Inverter AC units, Replacement of old aged and provision of new DG sets Over Nanded Division.
Interactive Panels with CPU (Q2), Online UPS (?10 KVA) With Battery Conforming To IS 16242 (Part 1) (Q2) (3 (3 ))
Desktop Computers (Q2), Online UPS (V2) (Q2), Random Access Memory (RAM) Card (V2) (Q3), Network Attached Storage (NAS) Device (Q4)
High End Desktop Computer (Q2), Online UPS (?10 KVA) With Battery Conforming To IS 16242 (Part 1) (Q2) (3 (3 ))
All in One PC, Line Intractive UPS with AVR, Online Ups- IS:9000, END POINT PROTECTION SOFTWARE/APPLIANCES (Version 2.0)
Line Intractive UPS with AVR, Online UPS Bidder Turnover (Last 3 Years) 6 Lakh (s) Experience Criteria 3 Year (s)
High End Desktop Computer (Q2), Online UPS (?10 KVA) With Battery Conforming To IS 16242 (Part 1) (Q2) (3 (3 ))
Online Ups Modular Type (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Past Performance, Bidder Turnover *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? No -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6649513 Dated : 05-09-2025 Bid Document 1/7 Past Performance 40 % Bid to RA enabled No RCM Applicable Yes Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Online Ups Modular Type (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, Bidder Turnover *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? No Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 3 Bid Number : GEM/2025/B/6691580 Dated : 16-09-2025 Bid Document 1/7 Number of Auto Extension count 1 Past Performance 40 % Bid to RA enabled No RCM Applicable Yes Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Online Ups Modular Type (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Past Performance, Bidder Turnover *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? No -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6447853 Dated : 13-07-2025 Bid Document 1/7 Past Performance 40 % Bid to RA enabled No RCM Applicable Yes Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Custom Bid for Services - BOQ item No 1 Semi Skilled Electrician per shift of 08 hours 3668 Shifts, Custom Bid for Services - BOQ item No 2 Supply only lead acid battery 180AH 12V 25 plates complete with first charge of battery 1 Each