Loading…
Loading…
6,200 results • Best match
Inverter with sine wave output
Inverter with sine wave output
On Grid Solar Inverter (Q3)
Inverter (V2) (Q2) (3 (3 ))
Main control card for inverter
INVERTER for water raising pump
Inverter (V2) (Q2) ( ( 3 3 ))
20 Watt Led Inverter batten
On Grid Solar Inverter (Q3)
On Grid Solar Inverter (Q3)
On Grid Solar Inverter (Q3)
Inverter with sine wave output
On Grid Solar Inverter (Q3)
Inverter Battery set with installation
Inverter with sine wave output
1.5 TON INVERTER SPLIT AC
Inverter with sine wave output
Inverter with sine wave output
On Grid Solar Inverter (Q3)
On Grid Solar Inverter (Q3)
On Grid Solar Inverter (Q3)
Custom Bid for Services - AMC OF DELTA MAKE INVERTERS Similar Category Customized AMC/CMC for Pre-owned Products
NOTICE INVITING TENDER FOR SUPPLY, INSTALLATION AND COMMISSIONING OF EXIDE MAKE 12KV,42AH SEALED MAINTENANCE FREE BATTERY BANK COMPRISING OF 32 BATTERIES
Inverter ( 31 box ), Battery For Invertor ( 62 box )
2 Ton Air Conditioner, Installation Charges Of AC, Drinking Water Cooler 150 Liter, Water Purifier, Inverter Battery 12.0 Volt Lead Acid Battery, Sound System With 4 Speaker Amplifier
Online UPS, Printer, Desktops Average Turn Over of Last 3 Years 20 Lakh (s) Experience with Gov. Required 3 Year (s) Online UPS ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 1.0 KVA As per GeM Catalogue. Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT-PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 15, 30, 60, 90, 120, 180, 2 40 Minimum VAH (VAH) 800 Warranty for UPS 1 1, 2, 3, 4, 5 1/7 (Years) Movable trolly for Batteries Without With, Without, Without trollery but with rack Warranty for battery 1 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Yes - 2/7 Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. R-41018072 - Type Test Certificate date 2017 - Name of Lab ATZ LAB - Address of Lab ATZ -PITHAMPUR - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Aditya Dhand 400005, INAS 330, Near Fire Station, Colaba Mumbai-400 005 10 15 3/7 Printer ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Specifications Printing Technology Laser Laser Cartridge Technology composite composite, separate toner and drum, Ink Type of printing mono mono, Colour Paper Size A4 A4, A3 Print Speed (A4) - Mono (PPM) 28 Print Speed (A4) - Color (PPM) 0 Resolution (Dpi) 1200*1200 - Memory (MB) 256 - Hard Disk Capacity (GB) 0 - Processor Speed (Mhz) 800 - Duplexing Feature yes - Duplex Print Speed (PPM/IPM) 18 Network Connectivity yes - Network Interface, if available Ethernet 10/100 - Wireless Connectivity yes - If Yes, Type of Connectivity Wi-fi Direct - USB Port yes - Paper Tray Capacity 250 - Number of Paper Trays 1 - Yield of Cartridge/Ink Tank/Ink Pack supplied with printer(Per Set) 3500 - Life of Drum in terms of number of Prints in case of Separate Drum and Toner cartridge technology (No of Prints ) 0 - Duty Cycle/month (No of Prints) 30000 - Operating Temperature Range (Degree C) 30-70 - Operating Humidity 10-80 - 4/7 (RH) (In %) Dimensions(In mm x mm x mm ) 22.39 x 37.05 x 40.74 - Weight (In kg) 6.9 - BIS Registration under CRS of Meity Yes - BIS Registration no R-41001821 (7) - On site OEM warranty (Years) 3 3 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Aditya Dhand 400005, Colaba Mumbai-400 005 1 15 Desktops ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values Processor Processor Make Intel Intel, AMD Processor Generation 7th 6th, 7th, 8th Processor Intel Core i3-7100 (3.9 GHz, 3 MB Cache, 2 Cores) Intel Core i3-7100 (3.9 GHz, 2 Cores) Motherboard Chipset Intel B250 As per GeM Catalogue. Expansion Slots (PCIe x 1) (Number) 0 - Expansion Slots (PCIe x 4) (Number) 2 - Expansion Slots (PCIe x 16) (Number) 1 - Graphics Graphics Type Integrated - Graphic Memory N/A - Operating System Operating System (Pre-Loaded) Windows 10 Profession al, Linux, DOS, Windows 10 Home Windows 10 Professional RAM Type of RAM DDR 4 - RAM Size (GB) 4 4, 8, 16, 32 RAM Expandability upto (GB) 32 16, 32, 64 5/7 RAM Speed (MHz) 2400 - Storage Hard Disk (GB) 1000 1000 Cabinet Cabinet Tower - Cabinet Volume (Litres) - - Internal Bays 2 - External Bays (Number) 1 - DIMM Slots (Number) 2 - Connectivity Wireless NA - Network Connectivity 10/100/1000 on board Integrated Gigabit Port - Ports USB Port 2.0 (Number) 4 - USB Port 3.0 (Number) 2 - Serial Port true - Parallel Port false - VGA true - HDMI true - Display Port true - Monitor Monitor Size (INCHES) 19.5 19.5 Monitor Resolution (PIXELS) 1366x768 1366x768, 1920x1080, 3 200x1800, 3840 x 2160, 1440 x 900, 1600 x 900 Monitor Certification - - Power Power Supply (Watt) - - Minimum Power Efficiency(%) 85 - Certification ROHS Compliance Yes - BEE/Energy Star for the given Model true - Input Devices Mouse Optical - Keyboard Standard - Generic Optical Drive DVD R/W - Internal Speaker true - On Site OEM Warranty (Year) 3 3, 5 * Bold specifications are the golden parameters. Consignees and Quantity 6/7 S.No. Consignee Address Quantity Delivery Days 1 Aditya Dhand 400005, Colaba Mumbai-400 005 10 15
Online UPS 5 KVA for Critical Infrastructures Average Turn Over of Last 3 Years 4 Lakh (s) Experience with Gov. Required 15 Year (s)
Estimate No.1664/NGP/2018-19 Providing 10 KVA UPS for VQC Hall at Second floor Architect office P.W.D. Compound Nagpur.
Comprehensive AMC For Smart Rack Solution with 42 U Size, 6 KVA UPS as per Scope of Work-20/20-01
PROVISION OF DEFICIENT BAGGAGE ROOM AT NOFRA, MANKHURD AND REPLACEMENT OF 60 KVA UPS AT TS MAHUL UNDER GE (NW) MANKHURD
Customized AMC/CMC for Pre-owned Products - 60 KVA UPS; TATA Liebert; Comprehensive Maintenance Contract (CMC); Not Applicable; No; 1 Year
Supply of maintenance free rechargeable battery capacity 12 volt 7 AH suitable for 1 KVA/ 2 KVA UPS Make:Exide or AMARON.
Inverter 1.5KVA sine wave, Inverter Rack, Connecting Leads, Battery 180 Ah, Installation with all required accessories, Breath Analyzer with printer
Custom Bid for Services - Comprehensive Annual Maintenance Contract (CAMC) for Vertiv Make UPS Systems Similar Category Customized AMC/CMC for Pre-owned Products
Procurement of Computers, Printers and UPS systems under General Administration Department for all departments at Headquarters and Taluka level under Zilla Parishad, Nashik
65.53.99.007.5 - 20KW SOLAR INVERTER, 65.53.99.007.5 - 20KW SOLAR INVERTER A, 65.53.99.008.5 - 50KW SOLAR INVERTER, 65.53.99.008.5 - 50KW SOLAR INVERTER B, 89002555 - MECH GEN INSTALLATION EQPT, 89002555 - MECH GEN INSTALLATION EQPT C
solar inverter, tubular battery, copper cable, Installtion BOQ Title BOQ BID
Supply of 48V/200 AH VRLA battery consisting of 24 Nos 2V/200AH cells in factory charged condition inserted in MS racks with intercell and inter module connectors as per IRS Specification No.S-93/9
120AH,VRLA BATTERY SET WITH 19 MONOBLOCK (6V EACH) PRE CHARGED WITH INTERCELL CONNECTORS WITHOUT M.S. CASING., as per Drawing/specification : RDSO/PE/SPEC/AC/0009- 2014(REV-2) W/O MS CASING(CRADLE). M
Split Inverter Air Conditioner 1.5 TON (Q3), Split Inverter Air Conditioner 2.0 TON (Q3)
Tender for annual rate contract for the period of 02 (Two) years for supply and installation of UPS batteries at various CNG stations of MNGL, Pune.
Tender for Annual Rate Contract for the Period of 02 (Two) Years for Supply and Installation of UPS Batteries at various CNG Stations of MNGL, Nashik.
8273 SPECIAL REPAIR FOR REPLACEMENT OF UPS BATTERIES AGAINST BER AT NCN DATA CENTRE (MBI) BUILDING AND PROVN OF ACs FOR OFFICERS MESS AT INS ANGRE
REPAIRS /REPLACEMENT OF OLD BATTERY BANK, LT PANEL, AMMETER, VOLTMETER AND CONNECTED ITEMS OF ELECTRIC INSTALLATION OF RA AND DA UNDER GE PULGAON
CAMC for Vertiv make UPS system installed at various locations at RCF Ltd, Chembur, Mumbai
65.31.00.041.5 - 12V 150 AH Lead Acid SMF Battery, ITC of 12V 150AH ARU Communication batt, 65.28.16.086.5 - 12V 120Ah SMF battery, ITC of 12V 120AH CPP DC Lighting batter, ITC of 12V 120AH RMP DM plant UPS batte, 65.31.00.009.5 - BATTERY SMF 12V ... Acid SMF Battery , ... 5 UPS battery , ... TDU UPS battery , ... AH SMF BATTERY , ... Acid SMF Battery , ... FCCU UPS battery , ... 120AH VRLA battery , ... 20 KVA UPS VRLA ...
Inverter, Battery 150 Watt, Cobra File, Paper Rim, Turkish Table Towel BOQ Title BOQ ITEM
Custom Bid for Services - CAMC of 5 Nos 30 KVA UPS of Uniline make located in INS and HYME for a per
Estimate No.1666/NGP/2018-19 Providing 10 KVA UPS for Meeting Hall at First floor Chief Engineer office P.W.D. Compound Nagpur.