Loading…
Loading…
3,229 results • Best match
Supply of Battery (Make Exide Amaron SF Sonic and Equitant) for Different Type Vehicle at Municipal Corporation, Udaipur. (ARC Basis) (With all Taxes, GST etc.) (e_07 / Garage_01_ Battery)
Power conditioning unit 5 KVA 96V, LifePo4 Battery Bank 96 Volt 200 AH, Power conditioning unit 10 KVA 120V, LifePo4 Battery Bank 120V, 400 AH
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2)
Line Interactive UPS with AVR (V2) (Q2), Online UPS (V2) (Q2)
Computer Printers, Online UPS, Multifunction Machines MFM, Laptop-Notebook, Desktop Computers
Online UPS Online UPS ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 3.0 KVA 3.0 KVA Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT-PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 4680 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 Movable trolly for Batteries Without trollery but with rack With, Without, Without trollery but with rack 1/4 Warranty for battery 2 1, 2 Degree of Protection IP20 IP21, IP20 Cabling 5 meters for input and out put Without With, Without Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with Yes - 2/4 IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. NTS/PPTL/UPS-310/03 - Type Test Certificate date 09.10.2015 - Name of Lab Nisaki Technology Services - Address of Lab No: 46, Park Road, 2nd Main, 10th Cross, Wilson Garden, Bengaluru, Karnataka 560027 - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sunita Yadav 303103, B.BD. GOVT. COLLEGE, VILL.& POST- CHIMANPURA TEH- SHAHPURA DISTT-JAIPUR 2 15 EMD 3/4 Required No ePBG Required No
Special repair and alternate switching of LED security lights, conversion of HPSV / HPMV high mast lights into LED flood light, 2x15 KVA UPS, 03 x high mast light and certain sanctioned works under GE (Army) Suratgarh at Suratgarh Mil Stn
Title1, Title2, Title3, Title4, Title5
Mark 4 7 inch 295mm Carbon fiber Frame Kit, Jumper T14 Radio Controller, 9000 MAH 6S 2P Lithium ion battery, Eachine EV800D 5.8G 40CH Diversity with FPV Goggles with DVR, Akk Race Ranger 5.8G 200 1600MW video Transmitter, Emax Ecoll 2807 1700KV Brussless Motor
Supply Erection testing and commissioning of Battery Banks 330V 900 AH Battery Bank Consisting of 165 Nos. cell in one Bank, 2V each cell, Lead Acid Tubular-NDP (With Accessories ) of UPS along with buy back and dismantling of existing HBL battery ba
Supply, erection, testing and commissioning of Exide or equivalent make battery banks, Type Tubular HDP, 220V/500 AH For Switchyard-II ,Source-2 and 220V/200AH For CHP of CTPP with buy back and dismantling of existing battery bank of CTPP Chhabra
Annual Contract for the work of routine/breakdown /capital mtc. work of LT SWGR, LT bus duct, AHP control panel, battery bank and battery charger, all CA area LT panels, cable laying, glanding, jointing and termination, cable cleaning of unit-I to V
110 Volt 200 Ah Low Maintenance Lead Acid Battery set comprising of 55 Nos. cells of 2 Volt each in dry & uncharged condition for traction & distribution system as per RDSO specification No. RDSO /PE/SPEC / TL /0040 ( Rev. 2) - 2021 with inter cell/end cell/ inter row/inter tier connectors, stainless steel fasteners, micro porous vent plug , sealed float guide, electrolyte in separate jar with M.S. stand & maintenance tools as per para No. 11.0 of above RDSO specification
Desktop Computer, Printer, UPS, Battery BOQ Title BoQ 2
Biometric Door Lock System, 5KVA Online UPS with 06 x Battery with Installation, 3KVA Online UPS with 15 x Battery with Installation, Traffic Road Barrier, Portable Handheld Security Scanner
Inverter with sine wave output Inverter With Sine Wave Output ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Inverter Governing specification Generally conforming to IS:13314 - Rating in KVA & Min. VAH ... - Inverter shall ... - Inverter Efficiency ... The inverters shall ... - Inverter shall ...
Power Conditioning Unit 1 KVA 24V, Battery Bank 200 AH
Supply of Battery (Make - Exide, Amaron, SF Sonic and Equitant) for Different Type Vehicle at Municipal Corporation, Udaipur. (ARC Basis) (With all Taxes, GST etc) (e_14 / Gagraj_ Battery Supply).
Supply of Battery (Make - Exide, Amaron, SF Sonic and Equitant) for Different Type Vehicle at Municipal Corporation, Udaipur. (ARC Basis) (With all Taxes, GST etc) (e_03 / Gagraj_ Battery Supply).
Supply of Battery (Make - Exide, Amaron, SF Sonic and Equitant) for Different Type Vehicle at Municipal Corporation, Udaipur. (ARC Basis) (With all Taxes, GST etc) (e_06 / Garaj_ Battery Supply)
Online UPS Online UPS ( 5 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA * Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT- PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 4000 4000 Warranty for UPS (Years) 3 3 1/4 Movable trolly for Batteries Without trollery but with rack With, Without, Without trollery but with rack Warranty for battery 2 2 Degree of Protection IP20 IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) /= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes * Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Yes * 2/4 Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. NTH(SR)/EL(C)/2014/29 2 * Type Test Certificate date 28.07.2014 * Name of Lab NTH * Address of Lab CHENNAI * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjay transport.it 302005, SAHKAR MARG, JAIPUR 5 15
Custom Bid for Services - Supply, Installation and Commissioning of 218 nos batteries including dismantling and buyback of old batteries of UPS Battery Bank at IOCL Chittorgarh Terminal Similar Category Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) Repair, Maintenance and Installation of Plant Systems/Equipments
Inverter LED street light supply work for emergency lighting in Ward No.31 to 60 Nagar Parishad, Tonk
Inverter LED street light supply work for emergency lighting in Ward No.1 to 30 Nagar Parishad, Tonk
2.0-2.2 Ton Split Air Conditioners Inverter Model, 5 KVA or Higher, 230 Volt, 50 Hz AC Voltage Stabilizer suitable for 2- ton AC, 2/3 Channel for AC automatic switching between two no. of AC suitable for 2-ton AC
SUPPLY 2x20 KVA UPS, INST and COMM 2x20 KVA UPS, NCAMC 1st year, NCAMC 2nd year, NCAMC 3rd year, NCAMC 4th year, NCAMC 5th year
CPU, UPS, MONITOR, PRINTER, ONLINE UPS, INFO KIOSK, NAS DEVICE, INTERACTIVE BOARD
Desktop i5, Laserjet Printer MFP, UPS, Online UPS 3 Kva, Battery 26AH
All in One PC (Q2), Computer Printers (Q2), Online UPS (V2) (Q2)
Supply of Battery operated portable hand drilling machine (18v Lithium-Ion Cordless Impact Drill) along with Carrying case and specifications as per the Annexure-1. Accepted Make/Brand:AS PER TENDER
Annual Contract for the work of routine, breakdown and capital mtc. work of LT switchgear, LTBD,AHP CP, battery bank and battery charger, all CA area LT panels, cable laying,glanding,jointing and termination and cable cleaning of unit-I to IV of CTPP
Annual Contract for R/B and annual/capital mtc. work of LT SWGR, LT bus duct, AHP control panel, battery bank and battery charger, all CA area LT panels, cable laying, glanding, jointing and termination and cable cleaning of Unit-I to IV of CTPP.
Annual Contract for R/B and annual/capital mtc work of LT SWGR, LT bus duct, AHP control panel, battery bank and battery charger, all CA area LT panel, cable laying, glanding, jointing and termination and cable cleaning of unit I to IV of CTPP
ADDN/ALTN AND PROVN OF CERTAIN E/M FIXTURE IN STORAGE SHED INSTALLATION OF EMI/EMC FIRE PROOF RITTAL HARDENED SHELL AT 3 AFRU, ADDN ALTN TO POWER PLANT COMMERCIAL SUPPLY BUILDING FOR POSITIONING UPS AND BATTERY BANK OF 265 SU AT AFS JAISALMER
Inverter with sine wave output Inverter With Sine Wave Output ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Inverter Governing specification Generally conforming to IS:13314 - Rating in KVA & Min. VAH ... - Inverter shall ... - Inverter Efficiency ... The inverters shall ... - Inverter shall ...
Online UPS Online UPS ( 6 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 1.0 KVA 1.0kva Technology MOSFET-PWM with inbuilt isolation transformer mosfet-pwmwithinbuilti solationtransformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 800 Warranty for UPS (Years) 1 1, 2, 3, 4, 5 Movable trolly for Batteries Without With, Without, Without trollery but with rack Warranty for battery 1 1, 2 Degree of Protection IP21 IP21, IP20 1/4 Cabling 5 meters for input and out put With with Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes N/A CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 N/A Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) N/A FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 N/A Voltage Regulation from no load to full load (%) /= 3% N/A 20% Overload limit for minimum 10 minutes Yes N/A Overall Efficiency (%) >/=90% N/A Total Harmonic Distortion(THD) (%) Maximum 3% N/A 50% Overload limit for minimum 1 minutes Yes N/A PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes N/A Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes N/A METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes N/A Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes N/A REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 Yes N/A 2/4 degree C, two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes N/A Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes N/A Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes N/A Type Test Certificate No. R-41018082 N/A Type Test Certificate date 2017 N/A Name of Lab BIS N/A Address of Lab BIS N/A As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Radhe Shyam Meena 334001, Off.Airport Director, AAI, Civil Airport, Nal Bikaner 6 15 EMD Required No ePBG Required No 3/4
CPU, SERVER, LED MONITOR, KEYBOARD AND MOUSE, 1 KVA UPS
Power Conditioning Unit 10 KVA 120V, Battery Bank 120V, 400 AH
PCU 5 KVA, Lithium Ferro Phosphate Battery Bank 96 Volt 200AH
Inverter with sine wave output Inverter With Sine Wave Output ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Inverter Governing specification Generally conforming to ... IS:13369, VRLA battery confirming ... minimum Inverter shall ... * Inverter Efficiency ... The inverters shall ... * Inverter shall ...
Customized AMC/CMC for Pre-owned Products - 60 KVA UPS; Novateur Electrical and Digital System Pvt Ltd; Comprehensive Maintenance Contract (CMC); Twice in a year; No, Customized AMC/CMC for Pre-owned Products - UPS 40 KVA; Novateur Electrical and Digital Systems Pvt Ltd; Comprehensive Maintenance Contract (CMC); Twice in a year; No, Customized AMC/CMC for Pre-owned Products - UPS 20 KVA; Novateur Electrical and Digital Systems Pvt Ltd; Comprehensive Maintenance Contract (CMC); Twice in a year; No
As per BOQ
Firewall - NGFW (Q2), Online UPS (V2) (Q2), Networking Server Rack (Q2) (3 (3 ))
Desktop Computers (Q2), Online UPS (V2) (Q2), Network Attached Storage (NAS) Device (Q4)
DESKTOP COMPUTER, PROJECTOR, VISULIZER, ONLINE UPS 5KVA, HDMI CABLE, VGA CABLE, INSTALLATION CHARGE
Online UPS Experience with Gov. Required 1 Year (s) Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 10.0 KVA 10.0kva Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT-PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz singlephase160v-260vs inewave50hz Output power Single phase 230V +/-1% sinewave 50 Hz singlephase230v-1sine wave50hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 16000.0 Warranty for UPS (Years) 1 1, 2, 3, 4, 5 Movable trolly for Batteries With with Warranty for battery 1 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for With With, Without 1/4 input and out put Paralleling kit for synchronising With With, Without Installation and Commissioning Yes N/A CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 N/A Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) N/A FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4.0 N/A Voltage Regulation from no load to full load (%) /= 3% N/A 20% Overload limit for minimum 10 minutes Yes N/A Overall Efficiency (%) N/A N/A Total Harmonic Distortion(THD) (%) Maximum 3% N/A 50% Overload limit for minimum 1 minutes Yes N/A PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes N/A Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes N/A METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes N/A Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes N/A REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of Yes N/A 2/4 (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes N/A Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes N/A Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes N/A Type Test Certificate No. R-41015563 N/A Type Test Certificate date 21-05-2019 N/A Name of Lab Bureau of Indian Standards N/A Address of Lab 9 Bahadur Shah Zafar Marg, New Delhi-110002, India N/A As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anil Kumar 302012, South Western Comd Sig Regt PIN -901252 C/o 56 APO 1 15 EMD Required No ePBG 3/4 Required No
Providing Inverter Type Split Air Conditioners for the office of Custom, Goods and Service Tax (CGST), Sikar (Raj.) Subwork/Packages: Electrical works
Repair of 5 KVA Gen Set, Repair of 1 KVA Online UPS, Repair of 1 KVA Online UPS PCB, Repair of Electric Siren 7 KM Rg, Repair of Electric Siren 8 KM Rg
Annual Contract for the work of R/B/C maint. work of LT switchgear, LT bus duct, AHP control panel, battery bank and battery charger, all CA area LT panels, cable laying, glanding, jointing and termination and cable cleaning of unit I to IV of CTPP
Supply of Desktop Computer, Printer, Scanner, Inverter with Battery and all in one computer system for District Collector office Pratapgarh