Loading…
Loading…
2,965 results • Latest
Renovation of overhead street light with providing and installation of PSC pole, stay set, Power cable and 14 nos street lights from Main Road Kathara panch mukhi hanuman mandir to Intake River mode and repair / maintenance of High mast lights
Repairing of RHS bend and cracked mast foot plate by straightening, welding and fabricated steel plates welding and worn out RHS front axle shaft of RECP650 Drill, Sl. No.RDC-1401/6021703 of GVP Ph II OCP.
Providing and fixing of end termination cable with heat shrinkable kit and jointing kit straight through with all accessories including lugs suitable XLPE/PVC cable 3 core H.T.(3.3KV-11KV) grade and 4 core LT. 1.1 KV grade cable and fixing of breathe
(A) Repairing and servicing of DG Set 160 KVA at Regional Store under G.M.Unit,Kathara (B)Repairing and servicing of DG Set 160 KVA at Kathara Area Hospital under G.M.Unit, Kathara (C) Repairing of D.G Set 32.5 KVA at G.M Bunglow under G.M., Unit,Kat
Flushing filter elements for BH100 Dumpers
Diversion of 3.3 KV and 440 V Overhead Lines under Birsa Project.
Installation of Submersible Pumps under Birsa Project.
Part repairing of 180 KW,3.3 KV motor and base plate for the pump motor set at Birsa Project.
Cleaning, testing and adjustment of 1700 number of CI test weights of 20 kg each for stamping and verification of under mentioned machines installed at Birsa Project.
Rep. of Dozer SI No. 13274.
Laying of different sizes of cable for power supply arrangement to newly installed weighbridge, pump for dewatering in slurry pond and cable end termination of cables in switch yard at Kedla Washery under Hazaribagh Area.
Repair and maintenance of 3KVA DG set at Chainpur Siding, partial repair of 11KV 440V transformer at chainpur siding, repair of floodlights, repair installation of AC ceiling fan and power supply rearrangement of Chainpur Siding road weighbridge
Self - Contained Drinking Water Coolers (V3) as per IS 1475 (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No Document required from seller Past Performance, Certificate (Requested in ATC), OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2026/B/7111548 Dated : 14-01-2026 Bid Document 1/7 Number of Auto Extension count 1 Past Performance 30 % Bid to RA enabled Yes RA Qualification Rule H1-Highest Priced Bid Elimination Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 7 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Estimated Bid Value 404838 Payment Timelines Payments shall be made to the Seller within 21 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC) Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No
Laying of main pipeline along diverted route for new pro-posed Sawang Washery site under Sawang Washery unit, Kathara Area
Repairing of (A) 02 Nos. 7.5KVA, 6.6KV/230Volt auxiliary transformer and control transformer of BE-195 Exc-1075 Shovel (B) 02 Nos. 7.5 HP compressor motor and filter fan motor BE-195 Exc-1075 Shovel (C) 28KVA welding machine at running sec-tion (D) 0