Loading…
Loading…
57 results • Latest
Hiring of water tanker for filling water at PTUs CTUs and PUs in entire NDMC Area
Hiring of Water tanker of Capacity not less than 8000 Liters of with booster pumps of 2 HP to 5 HP & filexible pipe of 2 inch dia of at least 30 mrs length along with one driver (with valid driver license & Id Proof ) and one helper with GPS installed including tools fuel mobil Oil ete. for running of water tanker and all damages wear and tear , punishment /challan due to violation of traffic rules etc. shall be borne by the agency himself, water tanker capacity should be 8000 -10000 Ltrs. and also it should be in good condition and up to date documents, should be maintained by the owner of the tanker which shall be, required along with all permission of plying in entire NDMC area anywhere at anytime (24x7) to designated location in NDMC area as desired and directed by Engineer-in-charge. Water tanker should be sent as and when required atleast for 8 working hours (one shift ) or upto maximum 100.00 km. running per shift as per requirement of department and upto entire satisfaction of Engineer in charge. Nothing extra shall be paid on this account and recovery @10000/- per shift will be made in the case of non operation of water tanker . Water shall be provided by NDMC from nearest pump booster /Bore well free of cost.
Repair and maintenance of PTUs CTUs PUs under jurisdiction of circle 06 and 07 under SD Division
Dismantling tile work in floors and walls laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
Repair and Maintenance of Infrastructure Assets R-V Division during 2025-26. Sub Head - Providing and laying PLC tile at Sharm Shakti Lane from Sansad Marg to Red Cross Society Gate.
The Schedule of Quantiny of Work is attached with the tender document/NIT
Sub Head - Comprehensive Maintenance Contract for two years for Public address system installed in various NDMC buildings i.e. Palika Kendra, NDCC PH-II and Convention Centre, Chander Lok Building, Mayur Bhawan, NDMC Schools and Barat Ghar etc.
Comprehensive maintenance contract for the public address system installed in the buildings listed below, including one visit per month for each building and on-call visits whenever required in case of any system defect. The services shall be carried out by a team consisting of two engineers, two technicians, and two helpers, with the objective of keeping the system fully functional around the clock. The technical staff of the agency i.e. Engineer and technician shall also provide basic training to the fire staff on the operation and basic upkeepment / maintenance of the public address system. All maintenance work must be carried out to the entire satisfaction of, and as directed by the Fire Officer / Engineer‑in‑Charge for the buildings listed below.
Pavement improvement plan in R II Division. SH P and L 80 mm thick Interlocking pavers at Parking of Palika Maternity Hospital and Khanna Market and P and L PLC CC slabs on footpath of 16 and 17 block Lodhi colony at 3rd Avenue Road
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
SITC of retrofit emission control devices in 500kVA DG Set installed at Bapu Dham Residential Complex and 200kVA DG Set installed at Type-II Residential Complex at Pushp vihar, New Delhi under NDMC.
Supplying, installation, testing & commissioning of retrofitting emission control device on existing 500 KVA DG set to reduce particulate matter, hydrocarbon and carbon monoxide emission by at least 70% to 90% and other harmful pollutants in 5 mode D2 cycle. The emission control device / equipment must be tested over an ISO-8178 5 mode D2 cycle for equivalent KVA rating and consisting of pressure safety valve if SS304, oxidation chamber particulate matter tarp of 15-2062 grade 'B' with high temperature resistance paint, vibration damper & gasket shielding & guarding of insulation with SS202 cladding, making structure, maintenance platform & ladder of lS 2062 grade B with high temperature resistant paint, Manual exhaust by pass system present- A manual valve will be given after the first stage (oxidation stage) and before the second stage (Passive Regenerative trap) of the DOFF, Noise attenuation is within the permissible limits, equipped with mechanical pressure relief system, capturing chamber made of resistance process treated mild steel etc. as required complete all as specified and directed. (Note- (I) The contractor should hire OEM for procurement and SITC of RECD shall be completed in all respect by the contractor.. (ii) Test reports and certifications from NABL lab approved by MoEFCC recognized laboratory regarding emission quality parameters before the device is installed and should qualify as per NGT norms, it shall be recorded and submit to Engineer-in-Charge. (iii) All specification and norms regarding OEM supplier and RECD are to be provided as per norms of Central Pollution Control Board. RECD having parameters/norms above mentioned shall be allowed, otherwise RECD of respective OEM will not be qualified for this project. The procurement and works related shall be on sole approval of engineer-in charge.) Make: Automoto Genset Solutions LLP, Inventive Gas Equipment, Cummins Technologies India Pvt Ltd, EO EnergyPvt Ltd.