Loading…
Loading…
298 results • Recent activity
hydraulic pumps-Floating Pump Hydraulic Pumps-Floating Pump ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values CONSTRUCTIONAL Pump Type Centrifugal action, Continuous run and directly coupled to engine Centrifugal action, Continuous run and directly coupled to engine Casing Material Powder coated Aluminium alloy as per IS : 617-1975 - Engine Type Air Cooled Four stroke Petrol Engine - Horse Power of Engine(HP)(on the basis of min discharge, max delivery Head, efficiency of pump and coupling (HP) 7.9 Ignition Transistorized - Starting Mechanism Recoil - Dry Weight of Floating Pump (Kg) <=30 Kg - Automatic float controlled throttle Yes - Float Assembly Material Fibre glass with Polyurethane foam - 1/3 Pump shall not sink even float is damaged Yes - Fuel Tank Capacity for continuous run of minimum one hour 5 - Fuel gauge Yes - Standard Accessories Water resistant air cleaner and muffler with pump - Marked with photo luminescent tape for visibility in darkness Yes - PERFORMANCE Delivery Head (Metres) >= 15 meters - Water Discharge (litres/min) >=950 litres/min - Discharge Solids upto size (mm) 15 - Suitable water depth to operate(mm) 25 - CERTIFICATION Engine shall meet applicable environmental protection norms and emission standards as per noise and emission norms issued or noticied by Govt of India Yes - Availability of Type Test Report to prove conformity of parameters to the specification from any ILAC/NABL accredited/Central Gov LAB Yes - Test certificate No and Date - - Name and Address of the Lab - - Product Warranty (Years) 2 - Service Warranty for Parts from date installation (Years) 5 - Type Test Report to be furnished to the buyer on demand Yes - * Bold specifications are the golden parameters. 2/3 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rajesh Bishya 457887, collectorate office alirajpur 1 15
Vehicle Hiring Service (Long Term)
Multifunction Machines
lead acid battery Lead Acid Battery ( 32 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1, 2 & 3) with latest amendments, Statinary Lead-Acid Batteries (with tubular positive plates) in Monobloc Container conforming to IS:13369/1992, Stationary cells and Batteries, Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991, Stationary Valve Regulated Lead Acid Batteries conforming to IS:15549/2005, Lead- Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to 1/3 IS:14257/1995, Lead- Acid Storage Batteries for Motor Vehicles conforming to IS:7372/1995 Nominal Voltage of Battery (volts) 12.0 Volt 2.0 Volt, 6.0 Volt, 12.0 Volt Material of container Polypropylene Hard Rubber, Fibre Reinforced Plastics (FRP), Polypropylene, ABS Rated Capacity at C20 discharge (AH) 100 Warranty (Years) 2 Years 1 Year, 2 Years, 3 Years, 4 Years, 5 Years Battery Condition Dry Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 100 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn., corresponding Ah Yes. - No.of cells per Battery (No.) 6 Cells for 12 Volt battery - CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab POST BOXNP. 1897 NEAR NASHIK PHATA BHOSARI PINA 411026 INDIA - Name of the Lab CENTRAL INSTITUTE OF READ TRANSPORT - Test Report No. C70647/1400175051 - Test Report Date 12/6/2014 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety 3996/240/1/VDRS/1982 4947 - 2/3 Requirements for Portable sealed secondary cells, and for Batteries made from them for use in portable applications * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 N Abdul Jaleel 744101, SECRETARY, PORT BLAIR MUNICIPAL COUNCIL, INDIRA BHAWAN, MOHANPURA 32 15
domestic refrigerators Average Turn Over of Last 3 Years 2 Lakh (s) Experience with Gov. Required 20 Year (s) Domestic Refrigerators ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values Specification Conformity to Indian Standrad IS:15750(2006) for Frost Free IS:1476 latest for Direct Cool, IS:15750(2006) for Frost Free ISI marked false - CML No. 0 - Capacity and Design features Storage Volume(NET CAPACITY) (Litres) 300 As per GeM Catalogue. Type of Door Double Single, Double Insulation Puff Puff, Polyurethane, Maxi 2, others Built in Voltage Stabilizer Yes - Method of Defrosting Frost Free Direct Cool, Frost Free Performance BEE Star Rating as on date 3 2, 3, 4, 5 Eco-friendly refrigerant yes - Compressor Power saver Compressor - Voltage Range at 43 230 (tolerance 10%) - 1/2 degree Centigrade (Volts) Material Coil Material Copper (Cu) Copper (Cu), Aluminium (Al) Finish and Colour Type of Finish Metallic Metallic, Matt, Printed Design Colour Black As per GeM Catalogue. * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mahesh Kumar Vaishnav 342304, AGRICULTURE UNIVERSITY OPPOISTE MANDORE RAILWAY STATION JODHPUR 2 15