Loading…
Loading…
298 results • Recent activity
patient care mattresses Average Turn Over of Last 3 Years 21 Lakh (s) Experience with Gov. Required 3 Year (s) Patient Care Mattresses ( 58 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values Dimensions Overall Length (mm, Feet) 1980 mm(6.5 feet) 1830 mm(6 feet), 1980 mm(6.5 feet), 2135 mm(7 feet) Overall Width (mm) 915 mm(3 feet) 762 mm(2.5 feet), 915 mm(3 feet), 1067 mm(3.5 feet), 1219 mm(4 feet) Thickness of Mattress (mm) 75 mm +/-0.5% 75 mm +/-0.5%, 150 mm+/-0.5%, 225 mm+/-0.5%, 300 mm+/-0.5% mm Features Material of Mattress poly urethane * Mattress with Sections 2 Sections * Fire Retardan, Anti Microbial and Water proof (as per IPX – 54 standard) properties of cover for Mattress Yes Yes 1/4 Color of Cover Material Blue * Cover Material for Mattress Heavy Helium * Density of Material of Mattress in (Kg/m3) 40 32-50 Product details, Certifications Product Code available on Web true * Product Code No. 42191810SD00028 * Drawing No. available on Web true * Drawing No. HOS 112018 PSPA4 * Availability Of Test Certificate From Govt Lab/NABL Or ILAC Accredited Lab For Firwe Retardant And Microbial Properties Of Cover Material Of Mattress false * Test certificate No. and Date NA * Name and Address of the Lab. where tested NA * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Gagandeep Singh Dhillon 171001, KNH Shimla 58 15
Sanitary Napkins Incinetator Machine with Smoke Control Unit Sanitary Napkins Incinetator Machine With Smoke Control Unit ( 13 ) Technical Specifications Specification Specification Name Values Allowed Values GENERAL Type - - Purpose Burn used Sanitary Napkins to sterile ash and stop automatically - Color - - Operation Mode Electronically operated, fully Automatic - Loading Type - - Stand provided false true, false Number of chambers Two - Trap Door available Yes - All MS parts Powder coated Yes - Spare parts should be available for Minimum 5 years from date of supply Yes - All electrical parts are ISI Marked Yes - DIMENSIONS OF MAIN UNIT Thickness of thermal Insulation material (mm) 25 25, 40 1/8 Thickness of MS/SS sheet of housing cabinet (external) (mm) 1.2 - Thickness of MS/SS sheet of burning chamber (internal) (mm) (Min) 3 3, 5 Higher is better Machine Width(mm) - - Machine Depth (mm) - - Machine Hight(mm) - - Machine Weight(kg) 5-15 5-15, 16-30, 31-50, 51-250 Door width(mm) - - Door height(mm) - - Thickness of door (mm) 20 20, 25, 40, 50, 60 Internal/burning chamber shape - - Flexible emission Outlet pipe dia (mm) - 25, 63, 76 Detachable ash tray length (mm) - - Detachable ash tray width (mm) - - Detachable ash tray height (mm) - - Stand Height (mm) - - Stand Width (mm) - - Stand Depth (mm) - - MATERIAL OF MACHINE UNIT Material of Housing cabinet (External) Stainless Steel sheet of SS-304 grade Mild Steel(CRCA) sheet, Stainless Steel sheet of SS-304 grade Material of Burning chamber (Internal) Mild Steel(CRCA) sheet Mild Steel(CRCA) sheet, Stainless Steel sheet of SS-304 grade Finish of MS parts of cabinet Epoxy anti rust proof painting for superior finish - Material of Thermal Insulation High Density Ceramic Fiber sheet High Density Ceramic Fiber sheet, High Density Ceramic Board CONSTRUCTIONAL FEATURES Thermal insulation of burning chamber housed in outer chamber Yes - 2/8 Burning Chamber tray provided Yes - Emission Outlet pipe location - - Means of connecting the unit outlet with flue gas emission pipe - - Type of door lock provided Latch lock - CONTROL & FUNCTIONAL FEATURES Temperature indicator provided Yes - Timer provided Yes - Auto cut-off temperature display Yes - Digital display to see actual and set temperature false - Minimum Burning temperature (degree C) 800 - Burning Capacity per day (Number of Napkins) 15-50 15-50, 51-100, 100-200, 200-500, 500-700, 700-1000, 1000-1250 Burning Capacity at a time (Number of Napkins) 1-15 1-15, 16-25, 26-50 Residue Ash per Napkin (gms) 1 - Burning time of full capacity Napkins/pads (minutes) 10 As per GeM Catalogue. Skin temperature of the unit under operation (deg C) 0-15 - Installation, training, demonstration and plumbing included Yes - ELECTRICAL AND SAFETY FEATURES Automatic digital controller for time Yes - Automatic digital controller for temperature Yes - Equipment ON/OFF indicator provided Yes - Power supply - - Electrical Power - - 3/8 Consumption(Watt) Minimum length of power chord to be supplied along with machine (mtr) 2 - Type of Heater Tubular heater - Power saver (auto power cut-off) Yes - Safety MCB provided (16A to 30A) Yes - Protection against electric shock when checked as per IS:302-1/2008 Yes - Minimum Insulation Resistance (IR) at 500 VDC (Mega Ohm) 2 - Maximum Electrical Insulation and Leakage current as per IS:302-1/2008, (mA) 0.21 - Maximum Earthing continuity test when tested as per IS:302-1/2008 (Ohm) 0.1 - HV test at 1000 V rms for 1 Sec when tested as per IS:302-1/2008 No breakdown shall occur during the test - SMOKE CONTROL UNIT (SCU) Type of SCU (Smoke Control Unit) - - Material of housing of Smoke Control Unit (SCU) Mild Steel(CRCA) cabinet Mild Steel(CRCA) cabinet, Stainless Steel of SS-304 grade Finish of MS parts of SCU cabinet - - Overall height of SCU (mm) - - Overall width of SCU (mm) - - Overall depth of SCU (mm) - - Number of chambers for filteration of smoke emission Two - Both carbon Control and Foul odour Control Chambers for filteration of smoke emission Yes - 4/8 Number of filters in Carbon control chamber One One, Two, Three Type of filters in Carbon control chamber Activated Carbon filter Teflon filter, Activated Carbon filter, Steel mesh filterr, Teflon filter & Activated Carbon filter, Teflon filter, Activated Carbon filter & Steel mesh filter, Ceramic blanket as a filter Number of filters in Odour control chamber One One, Three Type of filters in Odour control chamber Activated Carbon filter - Blower type "Centrifugal, direct driven" - Blower RPM 1800 1800, 2700 Power supply of SPU 230v +/-10%, 50Hz, Single phase, AC supply - Minimum length of flexible emission outlet pipe to be supplied along with machine (mtr) 3 - Cost of additional flexible emission outlet pipe, if required on actuals to be paid by the user Yes - EMISSION STANDARD FOR SMOKE Conformity to CPCB, Min of Environment & Forests standard HAZWAMS/30/2005-06 Yes - Particulates (Half hourly average) (mg/Nm3) (Max) 50 - HCl (Half hourly average) (mg/Nm3) (Max) 50 - SO2 (Half hourly average) (mg/Nm3) (max) 200 - CO (Half hourly average) (mg/Nm3) (Max) 100 - 5/8 CO (Daily average) (mg/Nm3) (Max) 50 - Total Organic Carbon (Half hourly average) (mg/Nm3) (Max) 20 - HF (Half hourly average) (mg/Nm3) (Max) 4 - "Nox (NO and NO2 expressed as NO2) (Half hourly average) (mg/Nm3) (Max)" 400 - Total dioxins and furans ( 6 to 8 hours sampling basis, Please refer guidelines for 17 concerned congeners for toxic equivalence values to arrive at total toxic equivalence) (ng TEQ/Nm3) (Max) 0.1 - Cd + Th + their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.05 - Hg and its compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.05 - Sb+As+Pb+Cr+Co+Cu +Mn+Ni+V+their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) 0.5 - Loss on ignition (max) (% dry weight of the material) 5 - PACKING Packing - - MARKING AND INSTRUCTIONS The appliance is marked as per IS:302-1/2008 Yes - CERTIFICATION Submission of Test Report from Central Government NABL/ILAC accredited Lab specifically Yes - 6/8 containing Electrical & Electronic parameters, Thermal insulation material of burning chamber etc in addition to the declared specification parameters at the time of supply Submission Test Report for equipment for compliance of Flue gas emission and ash upon combustion of Sanitary Napkins/Pads to Central Pollotution Control Board (CPCB) norms from NABL accredited lab at the time of supply Yes - Certification Available Other - Certificate for Manufacturing premises available ISO - Compliance certificate is to be furnished after conducting comprehensive performance test by the supplier Yes - Submission of all the certifications to the buyer along with supplies Yes - PERFORMANCE REQUIREMENTS Warranty (Yrs) 1 1, 2, 3, 4, 5 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sameer Rajkamal Ganvir 441302, Municipal Council Katol, Dist- Nagpur 13 15
biometric identification equipment Average Turn Over of Last 3 Years 13 Lakh (s) Experience with Gov. Required 12 Year (s) Biometric Identification Equipment ( 201 ) Technical Specifications Specification Specification Name Values Allowed Values Specification Type Fingerprint Scanner Device for use with Desktop, Laptop, Tablet, POS Device etc. Fingerprint Scanner Device for use with Desktop, POS Device etc., Iris Authentication Device for use with Desktop, POS Device etc. Certification for Device and extractor software/SDK STQC Certified - API/SDK Windows 7 and above (including Windows based Mobile Phone) Windows 7 and above (including Windows based Mobile Phone), Android 4.0 and Above, Linux Integrated USB 2.0 and above Connector Yes - Connector Cable to connect the Device to Micro USB & Standard USB Yes - UIDAI Certified Registered Device Yes - 1/2 (Copy of the certificate to be furnished when demanded by buyer) Conformity to the "Terms and Conditions of UIDAI Certified Registered Device" Yes - Warranty (Years) 4 4 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Patel Sureshbhai Koyabhai 361305, District Development Office, Jilla Seva sadan, Lalpur Bypass, dharampur, Jam-khambhalia 201 20
Vehicle Hiring Service (Long Term)
tent arctic camping and outdoor equipment Tent Arctic Camping And Outdoor Equipment ( 100 ) Technical Specifications Specification Specification Name Values Allowed Values SPECIFICATION Description of Item Tent Arctic Small MK-2 with all components and accessories conforming to IND/TC/0825(b) Tent Arctic Small MK-2 with all components and accessories conforming to IND/TC/0825(b), Tent Arctic Medium MK-2, Complete with all Components and Accessories conforming to IND/TC/0824(a), Tent Arctic Large MK-2, Complete with all Components and Accessories conforming to TSRDE/73/139 MATERIAL Material of Outer Fly Fabric Cotton Closely Woven 170g Dual Shade (White/O.G.) W.R. as per JSS:8305-5 ( For Tent Arctic Small ) Fabric Cotton Closely Woven 170g Dual Shade (White/O.G.) W.R. as per JSS:8305-5 ( For Tent Arctic Small ), Fabric Cotton Closely Woven 235 g Dual Shade (White/O.G.) W.R. as per JSS:8305-5 ( for Tent Arctic Medium ), Duck Cotton 610 g Dual Shade (White/O.G.) W.R., Rot Proofed, as per 1/3 IS:1422-1983, latest, Variety No-2, and IS:6803- 1972 ( For Tent Arctic Large ) Material of Inner Fly Cotton Fabric for supply Dropping Parachute Scoured (Type-1) as per IS:2970 ( for Tent Arctic Small and Tent Arctic Medium ) Cotton Fabric for supply Dropping Parachute Scoured (Type-1) as per IS:2970 ( for Tent Arctic Small and Tent Arctic Medium ), Cotton Fabric Dosutie Scoured as per IS:179-2009, Variety No-4, ( For Tent Arctic Large ) TEST REPORT Availability of Test Report from NABL/ILAC accredited or Central Government Lab to prove conformity of products to the specification. Yes - Test reports to be furnished to buyer on demand Yes - Name of the Lab TUV RHEINLAND INDIA PVT LTD - Address of The Lab 378 UDYOG VIHAR GURGAON - Test Report No. 0182404965 - Test Report Date 19/02/2018 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Pooja JCEOUSWDB 248115, Pashudhan Bhawan, Mothrowala, Dehradun. 100 15