Loading…
Loading…
17,100 results • Latest
Switch - push button - Emergency Fuel cut off and engine stop to EMD part No. 8384650.
Monthly Basis Cab & Taxi Hiring Services - SUV; 2000 Km per month round the clock 24x7 vehicle required for Sr DEN North SC; Outstation 24*7
Line Interactive UPSwith AVR (V2) (Q2)
Supply and installation of RO Water Purifier
Handheld LED Search Light
Hand-Operated Chain Pulley Block (V2) asper IS3832 (Q3)
Toner Cartridges/Ink Cartridges/Consumablesfor Printers (Q2)
(PH NO.:22016) CARVEDILOL 3.125 MG TAB,UNIT:TABLET/CAPSULE
(PH NO.:01001) ALENDRONATE SODIUM 70 MG TAB,UNIT:TABLET/CAPSULE
(PH NO.:37001) PROTAMINE SULPHATE 100 MG/ ML - 5 ML INJ,UNIT:VIAL
(1)'PATHAKOTHA CHERUVU' station- S&T arrangements in connection with Common loop facilities for Up & Down Loop Lines at PLU.(2)'KONDAPURAM' station-S&T arrangements in connection with the provision of new cross over for Common loop facility to the existing Down loop line. (3) 'Tiruchanuru' station - S&T arrangements in connection with provision of New Trip shed.(4) ONTIMITTA (VNM) station: Signalling & Telecom arrangements in connection with proposed PQRS Siding.
Hyderabad Division: SW(i) SC-MUE Section: Proposed Construction of 2 lane ROB in lieu of LC no.180 at Rly km 422/1-2 of span 1X36.00 M Composite Girder between DAB-BSX stations on MUE-SC section of HYB Division - Deposit work SW(ii) HYB Div: SC-MUE Section: Proposed Construction of 2 lane ROB at Rly km 418/0-1 of span 1X36.00 M Composite Girder between KEK- DAB stations on MUE-SC section on SH/MDR at km 1+002.9 at Atkur side road bypass near Dharmabad-Deposit work. - Electrical TRD Arrangements
S&T arrangements in connection with Provision of (1) 03 lifts for 12m FoB at ATP station. (2)03 lifts for old FoB at AD station.(3)3 lifts for New 12m FoB and 3 lifts for existing FOB at DHNE station.(4)two lifts for New 12m FoB at MALM station. (5)two lifts for existing FoB at RC station.(6)2 lifts for New 6m FoB and 2 lifts for existing FOB at RJP station.(7)2 lifts for New 12m FoB and 2 lifts for existing FOB at TU station.(8)two lifts for existing FoB at YG station.(9)one lift for existing FoB at Gooty Jn. (GY) station.(10)two lifts for existing FoB at KRY station.(11)two lifts for existing FoB at MPL station.(12)two lifts for new 6m FoB & Two no of Lifts for existing FOB at PAK station.(13)two lifts for existing FoB at PIL station.(14)06 Escalotors for New 12m FoB at DHNE station.(15)04 Escalators for 12m FoB at KHT station.(16)04 Escalators for New 12m FoB at MALM station.(17)04 Escalators for New 12m FoB at RC station.(18)04 Escalators for New 12m FoB at TU station. (19)04 Escalators for New 12m FoB at YG station.(20)06 Escalators for 12m FoB at ATP station.(21)03 No of Escalators for new 12m FoB at HX station.(22)f 02 lifts at Yerraguntla (YA) station.(23) Telecom arrangements in connection with the construction of new Trip shed at Renigunta station.(24)existing pipe culverts(4x0.90) with RCC boxes (5x1.50x1.50m) at Bridge No.154 @ Km.93/22-24 in KPD-TPTY section of Guntakal division.(25)replacement of steel girder bridge with PSC slab in Guntakal - Kalluru section (Bridge No. 25 UP)(26)new office building for RPF outpost at Mantralayam Road station.(27)Upgradation of Raichur goods shed duly dismantling existing HL platform at RC station.(28)GY-DMM section: S&T arrangements for Ancillary work to improve existing drainage arrangement at RUB No.109A (LC No:117) & 103A (LC No:118).(29) 03 lifts for 12m FoB and 1 lift for Existing FOB atDMM station.(30)06 Escalators for 12m FoB at DMM station and(31)two lifts for 12m FoB at KHT station.
Double locking plate for Traction motor HS-15250A.
Supply of 19" 24U Rack Enclosures, Networking/Server Rack as per specification
DEAD WEIGHT PRESSURE GAUGE TESTER COMPLETE SET
Supply, installation & commissioning of NAT edge processor & VOIP-based Handset for Service
Light Weight Torque Multiplier along with specialized reaction arm for torque enhancer to Model no: HT92-25 AWUR of M/s. NORBAR make (or) its Similar as per Technical specifications attached at Annexure-A.
Supply, Installation and Commissioning of Firewall
BEARING ECHO METER with following accessories.
Portable LED tower as per the Specifications attached. Make: ASKA or Equivalent. Note:Type test report covering all above points from central government National Test house shall be submitted along with supplies.
Supply of Power meter as per specification TEC/GR/TX/OPM001/04/NOV-13 of model Viavi OLS 35 or Similar including testing & transportation to site.
Bracket Tube Cap [RI 2104-1] confirming to RDSO Drg. No. ETI/OHE/P/2104-1 Rev-A
PCB card suitable for automatic changeover CLS panel Capacity 5 KVA to 10KVA as per RDSO specification no. TI/SPC/PSI/CLS/0020 or latest with all necessary accessories and the modification required. A common PCB card suitable for all CORE/RDSO approved makes of CLS panel. (Specifically Suitable for CONCORD, SUPREME, SUNTRON Makes OR SIMILAR)
Supply of Permanently lubricated HDPE Duct with outer diameter of 40mm and inner diameter of 33mm as per specification RDSO/SPN/TC/45/2013 Revision 2.0. The length of the duct shall be 1km. Two end plugs shall be provided along with the drum
Welding Hand Shield with Three side protection material of Ocular laminated glass, Type of filter : Welding Filter, Optical requirement : Spherical Effect for unmounted oculars, Oculars with filtering action, Length of ocular - 125mm and confirming to specification IS:5983 latest. FIRM OFFER MAKE BRAND-D&H SECHERON or similar,
SUPPLY, COMMISSIONING, TESTING AND PROVE OUT OF LIGHT WEIGHT WHEEL SKATE TROLLEY AS PER ENCLOSED SPECIFICATIONS.
Arc Welding Machine 300Amp, Rated Input Power (In kVA) : >=5<=10, Power Supply : 230 V Single Phase (50/60Hz).
SAE 100 R1 hydraulic hose having overall length of 1200 mm
Insulator's consisting of as per tender
Supply of Steel Wire Ending Clamp
Non-flamable solvent based adhesive for pasting flexible PVC flooring.
Thermoplastic Polyurethane spring pads (Happy Pads) for WAG5 Locos RDSO Specification No. MP-0.40.99.01 (Rev.-03) August, 2017 and conforming to RDSO Drawing No.SKVL-323, Alt 1.
Brake Shoe key as per S.C.Rly Drawing No. A3/EL/WAM4/0499, Alt 2.
Procurement of spares for Track machines
Entryand Mid Level Desktop Computer (Q2)
Hand Held Explosive Detector (HHED) asper MHAQR (V2) (Q2)
Aluminium Paintfor General Purposesin Dual Containeras per IS2339 (Q3)
1) Proposed New Byepass Line at Latur Road Bypass line for connecting Latur road- Parli vaijnath/Kurduwadi main line for OHE arragngements.2) Proposed New Byepass Line at Parli Vaijanath station for connecting Parlivaijnath- Latur Road & Parlivaijnath - Parbhani Main lines for OHE arragngements.
Fabrication and Supply of waterproof plywood Insulator box along with Locking arrangement. As per SCR HQ Drg No: E/252/TRD/HQ/WIB//OHE/2022-23 Dt.28.12.2022. Note: Sample Insulator box should be sent to consignee for approving before bulk supply by the firm.
Safety reflective waist coat jacketHigh visibility warning garments with synthetic slide fasteners of luminous flourescent colour of small, medium, Large sizes with logo of signals & Telecommunication department Guntakal division as per features furnished. Qty : 1)Small size : 150 Nos (flourescent orange colour) 2)Medium size : 350 Nos:flourescent orange colour & 3)Large size : 92 Nos. (flourescent orange colour).
Element air cleaner (outer) to Fleetguard part no. AF879M or to Donaldson part no.P182038 or to CIL Pt. No.3875391 or equivalent.