S&T arrangements in connection with Provision of (1) 03 lifts for 12m FoB at ATP station. (2)03 lifts for old FoB at AD station.(3)3 lifts for New 12m FoB and 3 lifts for existing FOB at DHNE station.(4)two lifts for New 12m FoB at MALM station. (5)two lifts for existing FoB at RC station.(6)2 lifts for New 6m FoB and 2 lifts for existing FOB at RJP station.(7)2 lifts for New 12m FoB and 2 lifts for existing FOB at TU station.(8)two lifts for existing FoB at YG station.(9)one lift for existing FoB at Gooty Jn. (GY) station.(10)two lifts for existing FoB at KRY station.(11)two lifts for existing FoB at MPL station.(12)two lifts for new 6m FoB & Two no of Lifts for existing FOB at PAK station.(13)two lifts for existing FoB at PIL station.(14)06 Escalotors for New 12m FoB at DHNE station.(15)04 Escalators for 12m FoB at KHT station.(16)04 Escalators for New 12m FoB at MALM station.(17)04 Escalators for New 12m FoB at RC station.(18)04 Escalators for New 12m FoB at TU station. (19)04 Escalators for New 12m FoB at YG station.(20)06 Escalators for 12m FoB at ATP station.(21)03 No of Escalators for new 12m FoB at HX station.(22)f 02 lifts at Yerraguntla (YA) station.(23) Telecom arrangements in connection with the construction of new Trip shed at Renigunta station.(24)existing pipe culverts(4x0.90) with RCC boxes (5x1.50x1.50m) at Bridge No.154 @ Km.93/22-24 in KPD-TPTY section of Guntakal division.(25)replacement of steel girder bridge with PSC slab in Guntakal - Kalluru section (Bridge No. 25 UP)(26)new office building for RPF outpost at Mantralayam Road station.(27)Upgradation of Raichur goods shed duly dismantling existing HL platform at RC station.(28)GY-DMM section: S&T arrangements for Ancillary work to improve existing drainage arrangement at RUB No.109A (LC No:117) & 103A (LC No:118).(29) 03 lifts for 12m FoB and 1 lift for Existing FOB atDMM station.(30)06 Escalators for 12m FoB at DMM station and(31)two lifts for 12m FoB at KHT station.
01-SNT-09-2026
01-SNT-09-2026
Open
12 Months
Raichur, Karnataka
₹0
₹7.8 L
12 Jun 2026
12 Jun 2026
22 Jun 2026
Supply of GKP type Location Boxes (a) Full size as perdrg. No. S&T/MFT/T.2378 Inspection by Consignee.
Supply of 'E'type lock of specified ward as per requirement with one key E-type lock to DRG. No.SA3376/M or latest and specification IRS: S30-64 or latest. Inspection by Consignee.
Supply of relay fixing frame for full location box. The frame shall be of approximate size 940mmx150mm and made with powder coated MS angle of 25mmx25mmx 3mm. The frame shall have suitable holes to fix in full location box. Inspection by Consignee.
Supply of relay fixing frame for half location box. The frame should be of 4 approximate size 470mmx150mm and made out with powder coated MS angle of 25mmx25mmx3mm. The frame should have suitable holes to fix in half location box. Inspection by Consignee.
Supply of Hylam sheet, resin bonded, grade P3 as per IS specification IS 2036 of 1974 or latest of following size:(a) Hylam Sheet of size: 2400mm x1200mmx6mm.Inspection by Consignee.
Supply of Hylam sheet, resin bonded, grade P3 as per IS specification IS 2036 of 1974 or latest of following size:(b) Hylam Sheet of size: 2400mm x600mmx6mm. Inspection by Consignee.
Supply of Terminal Block (a) Terminal block: 1 way Poly butylene Terephthalate (PBT) 7 of size 60mm (link centre to centre) as per RDSO DRG. No.SA23745/Alt.5 or latest, SA23746/Alt.5 or latest, S23747/Alt.5 and specifications IRS: S 75-2006 Rev. 2.0 (Tentative) or latest, IRS: S 23-88 Amd. 1 or latest. Inspection by RDSO
Supply of Terminal Block (b)Terminal block: 6 way Poly butylene Terephthalate (PBT) 8 of size 25mm (link centre to centre) as per RDSO DRG. No.SA23756/Alt.3 or latest, S23757tAlt.4 or latest and specifications IRS: S 75-2006 Rev. 2.0 (Tentative) or latest, IRS: S 23-88 Amd. 1 or latest. Inspection by RDSO.
Supply of Thermo shrink jointing kit for jointing underground 0.9mm dia conductor 6 quad cable as per specification IRS: TC 77-2012 Rev. 3 (Amd. ito Amd. 3) or latest. Inspection by RDSO.
Supply of Various Telephones and Telephone Power Supply unit (b) 4 wire train traffic control equipment with DTMF signalling way station equipment and way station control telephone as per specification IRS : TC 60-2007 Amd. I or latest. Inspection by Consignee.
Supply of Various Telephones and Telephone Power Supply unit (c) Desk type 2 wire, 11 12 way DTMF selective calling group telephone (Selective Calling I Group Telephone) complete as per specification IRS: TO 80-2000 Amd. I or latest with suitable power supply unit. Inspection by Consignee.
Supply of Various Telephones and Telephone Power Supply unit (d) Push button corded auto telephone with Caller ID facility of Beetel, Panasonic or Binatone make Inspection by Consignee.
Supply of Various Telecom Cable (a)Switch board cable 5 Pair / 0.6mm dia. as per TEC 68080:2002 or latest. Inspection by Consignee.
Supply of Various Telecom Cable (b) Switch board cable 10 Pair / 0.6mm dia. as per TEC 68080:2002 or latest Inspection by Consignee.
Supply of Various Telecom Cable (c )Switch board cable 20 Pair / 0.6mm dia. as per TEC 68080:2002 or latest GR WIR 0603 March 2002 or Latest Inspection by Consignee.
Supply of Various Telecom Cable (d) 50 Pair cable of 0.5mm dia, polythene insulated, 16 polythene sheathed, jelly filled underground telephone cable with poly aluminium moisture barrier, annealed copper conductor,polythene jacketed double steel tape armoured as per specification IRS: TC 41/97 Amd. 3 or latest. Inspection by Consignee.
Supply of Various Telecom Cable (f) PVC Twin (Tinned Copper Conductor, Double 'D' Type) cable as per standard TEC 68100:2003 or latest. Inspection by Consignee.
Supply of Various Telecom Cable (g) UTP CAT 6 Cable (Roll is 305 Mtr) of D.LINK/AMP/KRONE or similar make Inspection by Consignee.
Supply of Krone Termination Box complete with mounting (a) Krone termination of 20 pair . Inspection by Consignee.
Supply of Krone Termination Box complete with mounting (b) Krone termination of 50 pair. Inspection by Consignee.
Supply of Krone Termination Box complete with mounting (c) Krone termination of 100 pair. Inspection by Consignee.
Supply of Krone Termination Box complete with mounting (d) Krone insertion / extraction tool. Inspection by Consignee.
Supply of following type of Terminal block of Wago Make or Similar (with lever type disconnection & reconnection facility) duly fitted in C.T. box of approved quality, suitable for termination of cable from 0.4mm to 0.9mm conductor (a) 10 pair. Inspection by Consignee.
Supply of following type of Terminal block of Wago Make or Similar (with lever type disconnection & reconnection facility) duly fitted in C.T. box of approved quality, suitable for termination of cable from 0.4mm to 0.9mm conductor (b) 24 pair. Inspection by Consignee.
Supply of emergency socket box of FRP material as per specification RDSO/SPN/TC/44/2002 Ver. 3.0 with Amd. 1, 2,3, Corrigendum I or latest, DRG. TCDO/RE/001/2002 Ver. 0.1 or latest, TCDO/RE/001/2002/1 with socket six pin flat. Inspection by Consignee.
Supply of emergency socket six pin flat with 6 pin suitable plug as per specification IRS: TC 42-87 with Amd. 1, 2, 3 or latest. Inspection by Consignee.
Supply of Permanently lubricated HDPE Duct with outer diameter of 40mm and inner diameter of 33mm as per specification RDSO/SPN/TC/45/2013 Revision 2.0. The length of the duct shall be 1km. Two end plugs shall be provided alongwith the drum. Inspection by RDSO.
Supply of Plastic couplers - Slip fit / push type for permanently lubricated HDPE duct. Inspection by Consignee.
Supply of End plug for permanently lubricated HDPE duct. Inspection by Consignee.
Supply of Cable sealing plugs for permanently lubricated HDPE duct. Inspection by Consignee.
Supply of Rotary duct cutter suitable for cutting HDPE ducts of diameter 20mm to 42mm. The duct cutter shall have a facility of replaceable blades. The blades shall be of high carbon steel. Inspection by Consignee.
Supply of appropriate OFC patch cords as per direction of Engineer In charge, having insertion loss less than or equal to 0.1dB as per Telecommunication Engineering Centre (TEC) standard TEC 87070:2009 with GR TEC/T/OFCOFJ/ 155/2013 or latest. Inspection by Consignee.
Supply of Core Alignment Fusion Splicing Machine of model Fujikura 88S+ or Similar TEC Spec TEC/GR!OSM-01/04/SEP- 12 or latest. Inspection by Consignee.
Supply of smart OTDR (35/37 DB) as per specification TEC/GR/TX/OTD-002/04/AUG-19 of Viavi of 100A series or Similar. Inspection by Consignee.
Supply of Laser Source meter as per specification no.TEC/GR/TX/OPM-001/04/NOV-13 of model Viavi OLS 35 or similar. Inspection by Consignee.
Supply of Power meter as per specification TEC/GR/TX/OPM-001/04/NOV-13 of model Viavi OLS 35 or Similar. Inspection by Consignee.
Supply of IP based day and night high resolution camera spec with IP 66 rated water proof, dust proof for outside application with RDSO SPEC. RDSO/SPN/TC/65/2013 ver. 6 or latest. Inspection by RDSO.
Supply of 32 Channel NVR as per RDSOISPNITC/6512013 ver 6 or latest. Inspection by Consignee.
Supply of network 8 port switch with Ethernet and SFP port rg 45 10m network interface, product, delink model or similar, dgs-1008d. Inspection by Consignee.
Supply of 2-conductor disconnect / test terminal blocks (WAGO) or similar with pivoting knife disconnect and test port as per specification RDSO/SPN/189/2004 Ver. 3.0 or latest. WAGO Model No. 280-870 or similar. Inspection by Consignee.
Supply of 3 in 1 modular crimping tool for RJ45, RJ11, CAT-5 / CAT-6 Ethernet cable cutter crimping tool IMP make of Standard, D-Link, i-Ball, Belkin, Tech NXT, Fluke or Terabyte make. Inspection by Consignee.
Supply of single line RJ 11 Rosette box. Inspection by Consignee.
Supply of basic material to construct unit Maintenance Free Earth as per specification RDSO/SPN/197 Ver. 1.0 or latest consisting of the following: a) Copper bonded steel electrode 3m long, 17mm diameter with copper bonding thickness mini 250 micron and UL listed and marked - 1 46 No. b) Earth enhancement compound of RDSO approved brand supplied in sealed bags of minimum 10kg - 3 Nos. c) Copper strip with dimensions 150 x 25 x 6mm to terminate earth rod - I No. d) Copper strip with dimensions 300 x 25 x 6mm Main Equipotential Earth Bus bar (MEEB) - 1 No.e) Copper strip of with dimensions 150 x 25 x 6mm Sub Equlpotential Earth Bus bar (SEEB) - 1 No. f) 35 Sq.mm multi-strand PVC insulated Copper Cable (15meter). Inspection by Consignee.
Supply of Universal Locks with one steel key for every ten locks or par tther eof (For 47 example, if locks ordered is 10,1 key is to be supplied and if locks ordered is 20, 2 keys to be supplied. However, 2 keys to be supplied if locks ordered is between 11 and 19). Inspection by Consignee.
Supply of Double Walled Corrugated (DWC) HDPE duct of various diameter of length 48 of 6m as per specification RDSO/SPN/204/201 I Ver. 1.1 Amd. 1 or latest. The duct shall be supplied along with push-fit type 0-ring coupler or end cap.(b) DWC of outer Diameter 180mm and inner Diameter 153mm. Inspection by Consignee.
Supply of HDPE pipe of various diameter with material grade PE 100 as per specification IS Specification 4984: 1995 up to latest amendment. (a) HDPE pipe of 110mm Dia. Inspection by Consignee. Above/
A2-Supply Portion (Non SOR Items) 6225735.72 Below/P
Supply of Media converter Single mode Dual Fiber with Built in AC power supply unit supports 100Mbps with Driving distance of 15Kms with SC type connector and 10/100Mbps Ethernet port of model PCAT01/SA/SM15/SC/AC of MROTEK Make. Inspection by Consignee.
Supply of Wireless N ADSL2+4 Port Gateway with USB as per Technical Spec attached make : - ZYXEL Model :- AMG1312T10B Inspection by Consignee.
Supply of VDSL Modems. Inspection by Consignee.
Supply & Transportation of 12 Port LIU fully loaded with 12 simplex SC couplers and 12 SC connectors,Make- Digisol,D- Link or similar Accepted Make/Brand-12 Port LIU fully loaded Comtech Make. Inspection by Consignee.
Supply of Manageable non-POE 24 port switch with minimum 02 SFP ports. accepted Brand : D-Link. Inspection by Consignee.
Supply of 24 Port switch of D- Link make or similar. Inspection by Consignee.
Supply of 24 U Rack with standard accessories as per specification. 24U rack 600 x 650mm floor standing. Fan with tray - 2 Nos., Horizontal cable manager - 1 No., Power Manager 6 socket - 1 No., of BESTNET make or latest. Inspection by Consignee.
Supply of 2w/4w Fast Ethernet/LAN extenders 30 Mbps works up to 10 Km or more with Built-in internal dual AC 230V/ DC-48V power supply from a single socket as per specs make: MROTEK WL-LG or Cisco or Perle. Inspection by Consignee.
Supply of 4C 1U rack mountable device consisting of 4 E1 ports and three slots and 9 one slot populated with 2W/4W E&M supporting upto eight interfaces balance two slots empty. Unit supports both AC/DC power supply including 50pin cable one number for supporting both 2W/4W E&M. AC Adopter one no. for BPAC and UFSBI working on OFC media as per technical specification .ACCEPTED MAKE/BRAND - TEAM LINK FABIO 4C. Inspection by Consignee.
Supply of 48 port managed switch equivalent to CISCO WS C 2960 X-48TS-L., Layer-2 access switch as per specification of make: Net gear Model:GS752TP or similar. Inspection by Consignee.
Supply of Armoured 12 Core Fiber Cable, Inspection by Consignee.
Supply of 20 Pair PIJF cable. Inspection by Consignee.
Supply of Modem G.SHDSL 2 MBPSG.703 (E1) carrier end and V.35 at DTE end 13 modems. Digital modemsshall be capable of operating onbuilt in AC 230 V + 10%, 50 Hz aswell as DC 48V (In the range of 40V to 60V DC) as per RDSO Specification No.RDSO/SPN /TC/80/2020 Revision 2.0 or latest. Make Nomus/Cygnus/Teamlink or anyother make meeting RDSO specifications. Inspection by Consignee.
Supply of Power cable 3 core 2.5sq.mm 15amps 1100V, multistrand fire resistant Havells finolex fine cap as instructed by site in-charge. Inspection by Consignee.
Supply of Patch Cards 7' (DAX make). Inspection by Consignee.
Supply of SC-PC to SC-PC patch cards (5 mtrs length) with o db coupler. Inspection by Consignee.
Supply of single mode duplex fibre patch cord, SC-LC/SC of minimum 5 mtr length as per specified by site in-charge. Inspection by Consignee.
"Supply of fixed 4G wireless phone to support quad band GSM 850MHz / 900MHz / 1800MHz / 1900MHz, 2G,3G HSPA/UMTS- B1/B2/B5/B8 band, 4G-FTT/LTE B38/B40/B41 band, VolTE (HD voice calling service on 4G-LTE) of model No. Beetel F3-4G with following specification:1.LCD display with green back light 2. Supports Wi-Fi function (hot spot capability - 8 users) 3. Receive &send SMS (Max storage capacity of SMS-400) 4. Phone book with name storage for 500 Nos.5. Speed dialling function 6. Call log 7. 2 way speaker phone with adjustable receive volume 8. Hand set receive volume control 9. Last number redial 10. High performance detachable TNC antenna 11. Supporting phone lock function Make: Beetel / Visiontek / Motorola" Inspection by Consignee.
Supply of subscriber card (FXS card) to suit PD Mux of WEBFIL make as per RDSO spec.IRS TC-68/2012 or latest. 2W subscriber interface card 4 Channels per card compatible with WEBFIL make PD MUX as per latest spec. Inspection by RDSO.
Supply of tributary card for 2MB programmable primary digital drop insert multiplexer (PD MUX) as per spec.No.IRS.TC/68/12 with latest amendment of WEBFIL make. Inspection by RDSO.
Supply of Network Interface Module(NIM) for 2MB porgrammable PD MUX as per spec.No.IRS/TC/68/2012 with latest amendment of WEBFIL make. Inspection by RDSO.
Supply of Power Supply Unit (PSU card) for WEBFIL PDMUX as per spec.No.IRS/TC/68/2012 with latest amendment of WEBFIL make. Inspection by RDSO. Above/
Excavation of trench, including marking of cable alignment, clearing of jungle, roots of trees, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil including soft rocky area as per RDSO Sketch No. SDO/CABLE LAYING/003, as directed by engineer in-charge (a) Depth of 1200mm and width of 300mm Route Kilo
Excavation of trench, including marking of cable alignment, clearing of jungle, roots of trees, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil including soft rocky area as per RDSO Sketch No. SDO/CABLE LAYING/003, as directed by engineer in-charge (b) Depth of 1000mm and width of 300mm
Digging of cable trench to a depth of not less than 30 cm in rocky terrain/difficult terrain Concreting the trench with 150mm thick concrete with 1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size. All the material is to be arranged by contractor.
Track crossing/Road Crossing by Horizontal Boring method at culverts/track/pucca road as per SCR Drg. No. 5770. This also includes insertion of HDPE pipe of 110 mm/G.l Pipe of 100 mm in the bore drilled (HDPE pipe /GI pipe is to be supplied by Railway).
Trenching under Rails for crossing the track (Track Crossing) and refilling of trenches as per SCR Drg. No. 5768. The track crossing shall be done at right angles. The depth of cable trench 5 shall be 1.2 meter below the rail flange. The depth between top cable and the level of rail flange of the rail shall never be less than 1.0 meter. The ballast shall be stacked separately while making the trench and the earth soil shall be stacked separately. While re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. This work has to be done under supervision of supervisor of S&T and supervisor of P.Way.
Breaking of metal/ tar road and refilling after laying the cables as per drawing no.SDO/CABLE LAYING/010. The surface of the road shall be concreted to match with the old surface.
Cable laying and meggering. (a) Laying different type of cables in the trench. Termination covered elsewhere.
Excavation of coil pit up to a depth of 1 Mtr. X 1.5 Mtr. For providing coil at location box, point, signals etc., This includes back filling and ramming of trench / pit after laying the cable and consolidation of soil.
Supply & Laying of G.I Pipes with medium and threaded collar & coupler, quality to specification IS.1239 (part-I) 1990 and galvanised to specification IS 4736-1986.(b) G.I Pipes of 100mm diameter. Inspection by Consignee.
"Supply, transporting and installation of Concrete (RCC) Route Indicators at intervals 10 of 50 meters as per instructions of engineer in charge as per drawing no. SK 12/10. They should be of standard RCC with letters ""SCRS&T cable"" as per type of cable laid to drawing. In case of telecom quad cable joint locations it shall be painted with GREEN and ORANGE colour for normal indication of cable path." Inspection by Consignee.
Location box foundation and erection (a) Excavation of pit, casting concrete foundation and erection of apparatus case Full size as per SCR Drg. No. 5781 and fixing of 1 No.of 'E' type lock for the front door, latchingarrangement for backdoor, fixing of Hylam sheet (Hylam sheet 11 supply is covered elsewhere and Wooden Reapers also can be used in place of Hylam sheet for which supply & fixing covered elsewhere) and painting the apparatus case inside and outside with one coat of red oxide, two coats of aluminium paints outside and white paint inside including painting of termination, equipment and number particular on location box (foundation bolts and nuts, 'E type lock, cement, river sand, stone jelly of size 20/20mm, paints, varnish, fixing bolts and nuts and all other miscellaneous material required for the work shall be supplied by the contractor).
Location box foundation and erection (b) Excavation of pit, casting concrete foundation and erection of apparatus case half size as per Drg.No.SK/CN/1/89/B/1, fixing one E type 12 lock for the front door and latching arrangements for the back door and painting the apparatus case inside and outside with one coat of red oxide and two coats of aluminium paints outside and white paint inside (foundation bolts and nuts, painting of particular, E type locks, cement, river sand, stone jelly of size 20/20mm and nuts and all other miscellaneous material required for the work shall be supplied by the contractor)
Supply and fixing of following Teak wood reapers/ Blocks after applying two coats of wood primer.(a)Teak Wood Reapers suitable for Full Box: 75mm width x 20mm thick and length of 940mm. Per Unit means Per reaper. Inspection by Consignee.
Supply and fixing of following Teak wood reapers/ Blocks after applying two coats of wood primer.(b)Teak Wood Reapers suitable for Full Box: 50mm width x 50mm thick and length of 940mm and clamping the cable. Per Unit means Per Reaper. Inspection by Consignee.
Supply and fixing of following Teak wood reapers/ Blocks after applying two coats of wood primer.(c)Teak Wood Reapers suitable for Half Box 75mm width x 20mm thick and length of 470mm. Per Unit means Per Reaper. Inspection by Consignee.
Supply and fixing of following Teak wood reapers/ Blocks after applying two coats of wood primer.(d)Teak Wood Reapers suitable for Half Box: 50mm width x 20mm thick and length of 470mm. Per Unit means Per Reaper. Inspection by Consignee. Per
Cable termination including fixing terminals, fuses, LDs, Meggering of cables and recording the readings.
"Fixing relay bases, wiring in location boxes, bunching, fixing of relays as per circuit diagram. This includes fixing of condensers, resistance, 6 way I 1 way terminals / WAGO, ND type fuses, LED indicators for fuses as per type fuses."
Supply, painting and fixing of gland plate for Location box as per site requirement. (a) Full Location Box. Inspection by Consignee.
Supply, painting and fixing of gland plate for Location box as per site requirement. (b) Half Location Box. Inspection by Consignee.
"Fabrication, supply and erection of conventional Earth to Siqnallinq/Telecom equipments -Excavation of earth and providing earth pipe of size 50mm dia. 3.5mm thick 2.0 m. long G.I. pipe of heavy quality with masonry tub constructed around at earth locations as specified 21 by site Engineer. Alternate layers of 30kgs-charcoal and 30kgs-common salt to be filled in the pit while closing. The pipe perforation etc., to be carried out as per drawing No. SK 10/10. The earth pipe to be connected to the function with cable as supplied by Railways. The reading should be painted on the masonry tub. The masonry tub of 300 mm x 300 mm x 300mm (along with Kundi) should be covered with cement slab." Inspection by Consignee.
Earthing and soldering of cable armour. Per Unit means Per Cable.
Installation of single earth(maintenance free) including the following:- welding and fixing of copper tape (used as bus bar) welding of cadmium bronze cable to copper plate using material supplied vide item no. 1,2 of SPD of Sch-A. All the material supplied for mounting of copper tape, exothermic weld materials, tools and fixtures for welding copper tapes shall be arranged by contractor.a) Digging /Auguring/Boring of single earth pit of 100mmto 125 mm dia to the depth of approx. 2.8 meter.b) Insertion of 3.0 meter electrode and penetrating it at least 0.2 meter by pushing gently with sledge hammer where the natural soil is assumed.c) Filling of earth pit with earth enhancement compound (EEC) in slurry from and backfilling. d) Carrying out exothermic weld 23 connection on single earth electrode to a copper tape of 150X25X6mm. e) Carrying out exothermic weld connection on the copper tape of 150X25X6mm on earth electrode for connecting two 35 Sq mm cables for redundancy. f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite moulds, clamps, weld metal powders. g) Digging a trench to a depth of at least 0 .5 Mtr. and run the two 35 Sq mm earth conductor (procured against supply item) from earth pit to MEEB. h) Routing and termination of two 35 sq mm earth conductors in trench from earth pit to 300X25X6mm MEEB, which is to be fixed inside the equipment room with two insulation studs. i) 300X300X300 mm (inside dimension) concrete earth pit with a concrete lid, approx 50mm thick with pulling hooks, shall be provided to cover the pit. Back side of the cover will be painted in black and date of the testing and earth resistance value shall be written.
Strengthening of foundations of signals, Full/Half location boxes up to a height of 30 24 cm, by carrying out the earth work around the foundation, ramming of the earth, carry out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.
Transportation of materials from any Stores to Site and vice versa including loading and unloading.(b) Lead above 50 Kms. Per Unit means PTPK
Installation, wiring, testing & commissioning of 2 wire DTMF Selective Calling Telephone with power supply.
Straight through / derivation with/without transformer joints: Installation Thermo shrinkable jointing kits for straight through / derivation joints for LC gate, pump houses etc where VF 27 transformers are not required and derivation joint by using 2T transformer (to be housed in the joint) . This includes tapping of nominated Quad at a specific location shown by the Railway Engineer at site to the jelly field cable already laid. All material including valco tapes except thermo shrinkable jointing kit shall be supplied by the contractor. Per Unit means Joint.
Supply and fixing of 20 pair CT box and termination of jelly filled cable as per details given by engineer at site for LC gates / Pump house.(To be inspected by Consignee). Inspection by Consignee. Per Unit means Location.
Supply and fixing of 10 pair CT box and termination of jelly filled cable as per details given by Engineer at site for LC gates / Pump house. Inspection by Consignee.
"Installation of 100/50/20 pair Krone terminal Box on teak wood plank of size 330X200X25 mm plank and wiring.Teakwood plank and other materials like screws, bolts etc to be arranged by the contractor "
"Installation and commissioning of 4 Wire way station control equipment as detailed below: a) The way station equipment & Power supply unit are to be mounted on a rack as per Drg. No. COREIS&T/ALD /8K1436/95. b) The internal wiring should be wired between VF Repeater/ VF Transformer bay and MS Angle rack then to be extended to Dy.SS/ASM Table as per drawing shown in the sketch (All the wiring materials are to be provided by the contractor) except way station equipment & power supply unit"
Fabrication, installation and fixing of emergency socket post, box and emergency socket as per the drawing No. OH Eli .6N94. These emergency socket posts to be fixed along with the cable route at an interval of not more than 1 Km. Rail post will be provided by Railway
Strengthening the foundation of EC Post
"Painting and numbering of EC post with two coats of two colours of one feet each band with enamel paint of approved quality make like Asian, Nicholson and Berger and as directed by engineer in charge at site."
"Supply & installation of Rack 19"" wall mount 6U/500MM D with front glass door and 35 lock and key including the following: 1. I U Cable manager - I No. 2. 1 U Cantilever tray - I No. 3. AC distribution box 5X5 amps - I No. 4. Front panel H/W PKT of 10 Sets - I No. 5. Cooling fan of 230V AC operated " Inspection by Consignee.
"Supply & installation of Rack 19"" wall mount 17U with front glass door and lock and 36 key including the following: 1. 1 U Cable manager - 1 No. 2. 1 U Cantilever tray - I No. 3. AC distribution box 5X5 amps - 1 No. 4. Front panel H/W PKT of 10 Sets - I No. 5. Cooling fan of 230V AC operated " Inspection by Consignee.
Laying of HDPE duct 40133 mm dia in the trenches and in protective works already provided.
Blowing of armoured optic fibre cable (OFC Cable supplied by Railways) into the duct supplied vide other NS item of supply portion by using blowing machine and associated works. 10% 38 of OFC length to be blown extra on both ends of Duct i.e. total 20% of Duct length. Before blowing the duct integrity shall be tested. If any defect is found during duct integrity test, the entire length of HDPE duct from one chamber to another chamber is to be replaced by the contractor at his own cost. Payment will be made as per the length of Duct from which OFC is Blown.
Carrying out Duct Integrity test for PLB HDPE Duct, 40/33 mm Dia, as per specification.
Excavation of jointing pit and provision of RCC/FRP joint / Loop chambers of 90 Cms. Inner dia 60 Cms depth and 3mm thickness with two pieces of top cover with hooks each and bottom 40 cover with hole for drainage and cable entry as per Drg. No. RAILTEL/SR/OFC/ 2009/12 and as directed by Engineer to be provided at every joint location and at every Kilometre loop etc., The chamber shall be filled with sand mixed with ariti-stermic power, back filling and ramming of trench after HDPE duct laying, splicing and commissioning.
Supply and Installation of OFC joint enclosure and splicing of Optic fibre cable (24 fibres) and testing as per technical specification No. GR OJC-2/02 Sept 2003. Supply of Splice 41 Enclosure (24 fibre) shall be of TVS make Part No.1500-LI8X-XX or similar as per Board specification of TEC.& as per RDSO/SPN/TC/68/2014 Revision 1.0 amd 1 or latest . All materials including Fusion splicing machine used for fibre splicing and, OTDR for testing and other testing materials if any shall be arranged by the contractor. Inspection by Consignee.
Supply and installation of rack mounted 24 fibre Distribution Management System 42 (FDMS) of size 1U, of Reputed/Branded company make as per specification RDSO/SPN/TC/37/2020 Revision 4.0 with latest amendments. The FDMS shall include 24 SC-PC/Required adaptors having insertion loss less than or equal to 0.1dB and 24 numbers 900 micron 1.5m SC-PC/Required pigtails. Inspection by Consignee.
Testing of fibres between short haul station in both direction after splicing the required fibres
Supply and installation of 45mmx 45mm PVC channels for drawing switchboard cables at OFC cable huts and at stations as indicated by Railway Engineer at site. Inspection by Consignee.
Supply and fixing of different sizes of PVC casing /Pipes as required by Railway at site by fixing /clamping to the wall for indoor wiring purposes. All the material required for fixing PVC casing/Pipes are to be supplied by contractor. Inspection by Consignee.
Supply and installation of 230 volts AC / 48 volts, 25 Amps DC (2 1 configuration) SMPS battery charger as per RDSO spec. RDSO / SPN / TC / 23 / 99 (Ver-4) Amdt.-1 or latest. Inspection by RDSO.
Supply and installation of 48 volts 200 AH maintenance free VRLA battery in charged condition as per RDSO specification lRS:S-93/96(B) (Amd. 1 ) or latest. (2 volts 200 AH - 24 Nos. each set). Inspection by RDSO.
Supply and installation and commissioning of voltage stabilizer 5 KVA, single phase, servo controlled, wide range voltage stabilizer as per specification, input voltage range from 135 volts AC - 300 volts AC with changeover / bye pass switch. Inspection by Consignee.
Supply and installation of 19" - 42 U Rack complete with fittings for housing SDH equipment, FDMS, DDF and other equipment like cable managers, completely wired using krone module and other equipment like runaway ladders etc., as per technical specification below. It should be able to lock all the equipment with only order wire Telephone outside the rack. The rack should be of APW President / Rittal make or similar. The components of the rack are specified below. 49 It includes transportation and installation of rack in prefab/building at specified stations. 1. Rack S33 42U 600'W x 600D - 1 No. 2. Fixed side panels 42U x 600 D - 2 Nos. 3. Front Glass door plain 42U/600W - 1 No. 4. Rear MS Door Plain 42U/600W - 1 No. 5. Castor with brakes-2 Nos. 6 Fans directly mounted on the top 48V DC 90 CFM-2 Nos. 7. Krone mounting bracket - 01 Nos. 8. MCB Mounting panel with MCBs - a. 32 Amps, MCBs(DP) - 2 Nos. & 6Amps MCBs (DP) - 6 Nos. 9. Earth continuity Kit - 01 No. 10. Equipment Trays - 5 Nos. 11. Channel with cable loops 42U - 2 Nos " Inspection by Consignee.
Supply and installation of programmable Primary Digital Drop Insert Multiplexer fully wired for 30 Channels complete with all accessories from RDSO approved vendor as per RDSO specification IRS TC 68-2012 Rev.0 (with latest amendment) including connectors and cables required for installation including 100 pair Krone type MDF. Eachchannel card shall have minimum four channels per card. The single sub rack shall be capable of being equipped up to mm. 60 50 Channels without additional power supply unit. The MUX shall be wired & equipped with following circuits:1. 2 Wire/4 Wire E&M VF circuits (Minimum 16 No. Ckts) 2. FXO circuits: 6 nos. 3. FXS circuits Subs/Hotline circuits along with ringer card etc.: 08 No's 4. Acquisition card as per design5. Data User manual. 6. This also includes connecting all pigtails, optical patch cords etc to the SDH equipments. This also includes connection of SDH and primary MUX equipment with all interface cards to the 48V Bus including termination on DDF taking PVC cable over runway or a wall and termination of VF interface circuits to the Krone Termination box Inspection by RDSO.
Installation of power supply unit (230V AC input, 12V DC output and 7AH battery) at ASM office.
"Supply and installation of ONVIF 4MP IR bullet camera with Veri focal Lenses of 52 similar to Model No. DH-IPCHFW2231 RP-ZS-1RE6 and compatible to work with Dahua/Hiki vision/CP Plus/ Honeywell make NVR with required licensed video management software." Inspection by Consignee.
"Supply and installation of ONVIF 16 Channel NVR similar to Model No. 4416-4K82 series along with required licensed video management software compatible to work with Dahua/Hiki vision/CP Plus! Honeywell make 4 MP Bullet cameras." Inspection by Consignee.
Installation and commissioning charges (installation and configuration for video ip camera Above/
B2-Labour Portion ( Non SOR Items) 3766852.44 Below/P
Laying of data cable / power cable/CAT-6 cable/PA System cable/OFC
Supply, fixing and termination of RJ-45 jacks
"Supply, installation, configuration & testing of L3 switch set as per specification 3 consisting of (1). L3 stackable managed switch with 20x10G SFP + port and additional 4x10G (minimum) BASE-T/SFP + combo ports (2). L3 stackable managed switch with 20 x 10G BASE T port and additional 4x10G (minimum) BASE-T/SFP + combo ports of make: DLINKDXS-3400-24SC/EI+ DXS-3400-24TC/EI" Inspection by Consignee.
Supply and installation of 24 port POE Giga bit managable Switch with one SFP with power budget 382W model No. SG350 or better of CISCO/Juniper/Avaya make. Inspection by Consignee.
Cutting of trench across / on platform for a depth 10cm and width of 10cm with marble cutting machine and filling the trench after laying the cables and restoring the surface with marbles.
Supply and Installation of 8 port POE switch of HIK vision make or similar. Inspection by Consignee.
Supply and installation of Wi-Fi access point with POE facility of make: Digisol/Cisco/D-Link. Inspection by Consignee.
Supply & installation of 2KVA UPS systems . Inspection by Consignee.
Supply and installation of 4 port POE Hik vision make or similar Inspection by Consignee.
Supply and installation of Seagate 4 TB survilleance series hard disk. Inspection by Consignee.
Supply and installation of 43 inches colour monitor as persite requirement. Make:LG/Samsung/Sony. Inspection by Consignee.
supply and installation of 1KVA line interactive UPS system with built in batteries. Inspection by Consignee.
Supply and installation of UPS 5KVA, 2 hours back up. Make APC/Numeric/Emerson. Inspection by Consignee.
Supply and installation of 4 port Router for Tier-3 locations loaded with (02x10/100/1000Mbps LAN Ports, 4ports- 2 Mbps V. 35 WAN Ports along with 4nos of V.35 DTE cables as per RDSO Specification No. RDSO/SPN/TC/84/2008 Rev 0.0 or latest. Inspection by RDSO.
Connecting the cables to existing location box by breaking the location box foundation.
Hiring of unskilled labour (one man day = one shift of 08 hours)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022.pdf
ATTACHMENT
JPOSTCablecut.pdf
ATTACHMENT
FORMSANDANNEXURES.pdf
ATTACHMENT
SPLConditionsST_1.pdf
ATTACHMENT
GCCApril2022Amendments11compressed_1.pdf
ATTACHMENT
Download all tender documents and submit your bid