Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
127 results • Latest
Human Resource Outsourcing Service
Security Manpower Service
Security Manpower Service
Potable water purification system
Air Conditioner
Compatible Cartridge
domestic refrigerators
Air Conditioner
Air Conditioner
Laboratory Refrigerator
Laboratory Refrigerator
Compatible Cartridge
Online UPS
Desktop Computers
Desktop Computers
scanners
Multimedia Projectors
scanners
Desktops
Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 15.0 KVA 15.0 KVA Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT-PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power Three phase 300 V - 450V sinewave, 50Hz Three phase 300 V - 450V sinewave, 50Hz Output power 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 26000 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 Movable trolly for Batteries With With, Without, Without trollery but with rack Warranty for battery 2 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for With With, Without 1/4 input and out put Paralleling kit for synchronising With With, Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of Yes - 2/4 (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. 1111 - Type Test Certificate date 01-03-2018 - Name of Lab bpe - Address of Lab dELHI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vijeeshna V 685551, SPICES BOARD, SPICES PARK, PUTTADY - 685 551, GSTIN - 32AAIAS3118C1Z0 1 15 EMD Required No ePBG Required No 3/4