Loading…
Loading…
20 results • Latest
Repair reconstruction of Drains new drains at Old University Campus University of Jammu Jammu
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix)
Construction of RCC boundary wall of the Old Campus along the road from Dr. Pandas residence to Main Gate at Old University Campus University of Jammu
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix)
Construction of sump tanks for Teacher Officers staff quarters at lower residential at New University Campus
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix)
Reconstruction of boundary wall behind Sarojini Naidu Girls Hostel at New University Campus
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix)
Backup system and allied works for Surveillance System of Proctorial wing, Main Campus, University of Kashmir.
Supply, installation, testing & commissioning of 10kVA, 3 phase in and 1 phase out UPS, with 2-3 hr backup with following technical specifications General: UPS shall be free from workmanship defects, sharp edges, nicks, scratches, burrs, etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be functional. Technology: Microprocessor based Digital Control, IGBT based, True on line AC to DC conversion and then DC to AC. Waveform: Pure Sine wave Input Voltage: 1.732 x (130-270V) 3 phase (Generator Compatible) Input Frequency: 50 Hz +/- 5%. Input Power Factor: 0.99 Output Voltage: 220V +/- 2%. Single Phase Out Put Power Factor: 1 Output Frequency: 50Hz +/- 2%, tracking & synchronizing with mains frequency 50Hz +/- 0.2% in Free Running Mode or Battery Mode" THDI: < 5% with full load. Harmonic Distortion: < 3% THD (Linear Load) & < 5% THD (Non Linear Load) Inverter Efficiency: > 90% Crest Factor: 03:01:00 DC Bus Voltage: Variable (192V-240) DC Charging Current: Variable (2-12A) Over Load On Batteries: 110% for at least 300 secs. If overload exceeds UPS shall go in Bypass mode and auto recover on removal of load. By Pass Switches: Built in Static/Automatic Bi-Directional Type
Internal repair and replacement renovation of various staff quarters where ever required after he clearance from Estate deptt
Repair to plaster of thickness 12mm to 20 mm including cutting the patch & preparing & plastering the surface of the walls complete including disposal of rubbish to the dumping ground with in 50 m lead. With cement mortar 1:4 coarse sand. ( Internal & External Plaster)