Loading…
Loading…
94 results • Best match
IE Services for Const of new 2lane with paved shoulder coastal Highway from Konark to Paradeep Km.79.400 to Km. 160.180 on Hybrid Annuity Mode in the state of Odisha PKG II
RFP No./ ORDIV-22011/2/2026-Odisha Division, Tender Title: Independent Engineer Services for Construction of new 4-lane Access Controlled Coastal Highway from Rameshwar to Konark (km.0 to km. 79.400) on Hybrid Annuity Mode in the State of Odisha (Package-I).
RE E-TENDER FOR PROCUREMENT OF CONSUMABLE ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)
45 I14.01(a)/C Fully automatic non ported closed IV Catheter with Passive safety shield located inside the HUB before activation deploys automatically, cannot be bypassed and requires no user activation, Catheter material FEP/PUR/Violon/Certon, four embedded Radioopaque contrast lines, Universal Back cut bevel, multi-access blood control septum to prevent blood exposure, hydrophobic membrane with transparent flashback chamber and double flashback mechanism, Integrated Stabilization Platform, Power Injectable – Pressure rated for contrast media application at 300 psi ( 18G,20G,22G,24G) EACH
RE E-TENDER FOR PROCUREMENT OF CONSUMABLE ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)
45 I14.01(a)/C Fully automatic non ported closed IV Catheter with Passive safety shield located inside the HUB before activation deploys automatically, cannot be bypassed and requires no user activation, Catheter material FEP/PUR/Violon/Certon, four embedded Radioopaque contrast lines, Universal Back cut bevel, multi-access blood control septum to prevent blood exposure, hydrophobic membrane with transparent flashback chamber and double flashback mechanism, Integrated Stabilization Platform, Power Injectable – Pressure rated for contrast media application at 300 psi ( 18G,20G,22G,24G) EACH
RE E-TENDER FOR PROCUREMENT OF CONSUMABLE ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)
45 I14.01(a)/C Fully automatic non ported closed IV Catheter with Passive safety shield located inside the HUB before activation deploys automatically, cannot be bypassed and requires no user activation, Catheter material FEP/PUR/Violon/Certon, four embedded Radioopaque contrast lines, Universal Back cut bevel, multi-access blood control septum to prevent blood exposure, hydrophobic membrane with transparent flashback chamber and double flashback mechanism, Integrated Stabilization Platform, Power Injectable – Pressure rated for contrast media application at 300 psi ( 18G,20G,22G,24G) EACH