REPAIR OF DAMAGED AND UNSV SUBMAIN WIRING, TUBE LIGHT FITTING, SWITCH SOCKET ETC AT MH NAMKUM AND UNSV LT PANELS DAMAGED INSULATOR AT NAMKUM AND KHOJATOLI UNDER GE RANCHI
M & L for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8cm after laying the cable complete all as specified and directed.
HT Line related electrification work at RDF plant aawali-rojdi.
P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. 63 mm
WORK SERVICES FOR E/M SERVICES AT GUARD POST OF MED REGT AT KHOJATOLI UNDER GE RANCHI
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed.
SHIFTING OF 02 NOS OF SECURITY GATES IN TECHNICAL AREA A AND B AT IRDE UNDER GE(I) R AND D DEHRADUN
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection covers/ bricks & stacking serviceable bricks for reuse and disposal of unserviceable covers within 50 m complete all as specified and directed. Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
Upgradation of Electrical Installation work of Raghunathpur Govt Polytechnic at Sarbari in the District of Purulia
Laying of two cables above 35 sqmm and upto 185 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed[F-2/2(b)]
Provn of Facilities for Veer Naris, Veterans and Visitors as special Item of Work at National War Memorial
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note :-Punned down thickness of sand shall be considered for measurement)