Loading…
Loading…
2,403 results • Best match
REPAIR/REPLACEMENT OFSTREET LIGHTS, SOLAR LIGHTS, OH LINES TO UG CABLES OF STREET LIGHT FEEDER AND CONNECTED WORKS UNDER GE(AF) KALAIKUNDA
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed.
PROVISION OF DEFICIENT MARRIED ACCOMMODATION FOR SAILORS PO AND BELOW AT NCB CHENNAI
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm Complete all as directed.
1278 - Providing and Fixing Interlocking Paver Blocks, Street lights poles, Boundary wall and other miscellaneous work in Staff Quarter near CIPET Murthal under MC Sonipat
[24.2.4.2]LT CABLE 4.2. Laying of underground cable in pipe /existing open/closed trench etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core [Through Rate]
Ajmer Division-"Provision of 72 CCTV cameras with monitoring and recording system at all Major Booking office & PRS counters, 22 Stations (29 Locations)."
Description:- Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a
Installation of mini high mast at Kirloskar road, Belgangadhar Tilak Chowk, Kambli Khoot, Ashok Chowk in Ward No.4 of Belagavi City Corporation. (Reserved for Category-1 Contractors Only)
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm
CONSTRUCTION OF ADDITIONAL 5MVA FOR 33/11KV SUBSTATION BADALAPUR JAUNPUR AND INCREASING CAPACITY OF 33/11KV SUBSTATION SIDA SATHARIYA FROM (2X5) MVA TO (2X10) MVA, DISTT. JAUNPUR ON SEMI TURNKEY BASIS.
Laying & dressing of 11 kV, 3*300 sqmm underground cable from 5MVA T/F to 11 kV incoming switchgear in the trench 650 mm wide, 1000 mm deep providing 75mm fine sand, cushion beneath and 75mm fine sand cushion above the cable. The cable shall be duly protected by bricks, sand & stone slab. The work includes supplying of fine sand, bricks and stone slab are refilling and ramming of the left out soil, closing the trench and leveling. Spare cable shall be left and burried in the trench in the shape of rings at both ends cable laying work includes unrolling cutting mage ring and sealing both ends of the cable. (All required materials likes sand, bricks & stone slab etc. will be provided by contractor)