SPL REPAIR /REPLACEMENT OF ASBESTOS ROOF SHEETS AND ALLIED WORKS IN BLDG NO E-110 OF PINE OFFRS MESS UNDER AGE B/R-III AND AGE E/M-II OF GE (SOUTH) MEERUT CANTT
M&L for washed river dry sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling andhard punning complete all as specified directed.
SPL REPAIR TO BOUNDERY WALL ALONG CFL AND ST 7 8 LENGTH 1250 MTR AND AC SHEET ROOF FLASE CEILING WINDOWS AND DOORS OF BLDG NO T4 T4 A1 AND T4 A2 OF COMPOSITE FOOD LAB ASC AT KWC TIMARPUR AND OTHER SANCTION WORK UNDER GE NORTH DELHI CANTT10
M&L for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable all as directed.
CA NO. GE AF NO.1 / GUR-43 / 2026-27 REPAIR AND MAINTENANCE OF ILLUMANATION LIGHT, SECURITY STREET LIGHT, STREET LIGHT, HIGH MAST LIGHT, POLE PAINTING, JUNCTION BOXES, TIMER PANEL, CABLES ,GATE LIGHT, GARDEN LIGHT AND OTHER MISC WORK AT 13 BRD
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out soft/loose soil complete all as specified and as directed for foundation of stay, laying of cable etc.
REPAIR TO LT UG CABLE, LT PANELS, APFC PANEL, MCCBs, REPAIR/ SERVICING OF DG SET AND OTHER CONNECTED WORKS AT HATTIGOR MIL STN UNDER GE RANGIA
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
SPECIAL REPAIR TO BLDG NO. P-133 AND P-134 MD ACCN AT TICCA AREA UNDER AGE (I) DALHOUSIE
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
REPAIR /REPLACEMENT OF HT OVER HEAD LINES HT UG CABLES GODs AND OTHER CONNECTED WORKS AT LANSDOWNE UNDER AGE(I) LANSDOWNE
Supply and laying cable protection bricks, common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed.