Loading…
Loading…
2,701 results • Best match
Repair works to New Kalyan Mandap /Biju Convention centre and Jaydev Sadan
Providing fitting fixing of wooden stage floor by providing sal wood beam of size 75mm x 20mm placed 600mmx600mm C/C stage front to back wall will be fixed up with MS Clamp , nut bolt washer etc.on your existing concrete floor and 50mmx50mm runner will be placed by 600mm x600mm C/C in opposite direction . Anti termite materials will be placed privided on it. After that provide Gamar/ Hollock wood planks of 1.5'' thick 5'' width and minimum of 4' length with rabbit lapping joint to be placed on it by screw. Cable laying duct for sound and stage light work.finally finished with wax polish.This scope of work excluding the civil work. The total work will be executed as per the approval of Engineer in charge.
WORK OF CONSTRUCTION OF 01 No. 33/11 KV SARDARNAGAR BAY AND SUPPLY OF ASSOCIATED MATERIALS AT 132 KV S/S SHATRUGHANPUR UNDER ETD-I, GORAKHPUR
Laying of 3.5*95sq mm size LT Power cable from LT ACDB cubical to Main ACDB for Switchyard Lighting through 50 cm below the ground level after excavation of trench of suitable size covering the cables with river sand and Ist class brick lining along and over the cable, then back filling & levelling of the trench cover after laying of cables including termination of cable on both sides with crimping of Lugs.
CONSTRUCTION OF GUARD ROOM ALONGWITH BATHROOM AT SBS ENCLAVE UNDER GE (WEST) FEROZEPUR CANTT
M&L for Sand cushioning using sand suitable for plaster works to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep punned to 10cm after laying and stretching the cable complete all as specified and directed. Note : 18 cm punned thickness shall be measured and paid.
PROVN OF RAIN SHELTER AND WAITING ROOM WITH BATHROOM INFRONT OF BLDG NO P-29 AT COLABA UNDER GE (WEST) COLABA, MUMBAI
M&L for local sand coushioning with dry and clean over and under the cable for protection of cable, 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building, complete all as directed and specified.
SPECIAL REPAIR TO BLDG NO T73 (OR LINE) OF 27 MTN DIV PRO UNIT AT KALIMPONG MIL STN UNDER GE 867 EWS
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches, complete all as specified and as directed.
SPECIAL REPAIRS TO BLDG NO T91 AND T440C (OTM ACCN) OF 527 ASC BN AT KALIMPONG MIL STN
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches etc. complete all as specified and as directed.