REPAIR TO INTERNAL WIRING AND OTHER CONCERNED WORKS AT DOMESTIC AREA UNDER AF STN AMRITSAR
M&L sand cushioning with a layer of dry river sand 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts. Complete all as specified and directed Note: Punned down thickness (overall 18cm), shall be considered for measurement and payment.
PROVN OF MI ROOM FOR MIL STN MUZAFFARPUR
Supply & laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm thick over the cable complete all as specified and ditected.
Setting up of Flatted Factory Complex at Chabua, Dist. Dibrugarh
LAYING OF MV CABLES: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm
SPL REPAIR TO TOILETS, DOORS, WINDOWS AND SEWAGE SYS APS UNDER GE SOUTH AT BATHINDA MIL STN
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth for foundation etc or for shafts , wells, cesspits, manholes , septic tank, for laying of cables , laying of pipes not exceeding 10 Sqm on plan and not exc 1.5 meter depth and getting out in soft/loose soil etc complete all as specified and as directed by Engineer-in- charge.
Electrical work in the Construction work of PHC Building at Mahanpur Bansur District Kotputli Behror
Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
SITC OF MINI HIGH MAST IN UMC AREA (e_04 / Light_02)
Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth