Loading…
Loading…
2,811 results • Best match
ELECTRICAL WORK RELATED TO DG SET INSTALLATION AT RAC BATTALIAN CHAINPURA ,JAIPUR
Excavation of trench of size 75 cm (Depth) x 35 cm(Width) for laying of suitable no. of LT cables (Inter spacing between cables should not be less than 2 D) in ground with following procedure :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 100 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable, (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth.
REPAIR, MAINT AND REPLACEMENT OF LT PANELS, APFC PANELS, FEEDER PILLAR BOXES AND MISC ITEMS AT AF STN BHUJ
M&L for road cutting for laying cables in GI pipe and making good disturbed surface by using suitable ratio of PCC all as specified and directed. (Note Laying of cables and GI pipe will be measured separately under respective items)
SITC OF TRANSFORMER IN NAGAR NIGAM OFFICE.
Add Extra for Laying of one number XLPE power cable of 11/33 KV (Earthed) voltage grade direct in ground including excavation of trench of size 120 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
SITC of Plant Periphery CCTV Surveillance System at BRBCL Nabinagar
UTP CAT6 Cables Laying
Supply and Fixing of removing old poles and installing new decorative pole with decorative lights and solar lights ,cabling etc work , ISBT Dehradun.
CABLES Aluminium Armoured Cable:/ Copper Flexible Cable Voltage: 1100V Conductor:Stranded Class 2 Aluminium Conductor Insulation: XLPE as per IS 7098(Pt-1)/88, Latest Inner Sheath: Wrapping of Tape inner sheath Armoure: Galvanised Steel Flat strip armour Outer Sheath: Extruded FR-LSH PVC Type 'ST2' as per IS:5831 Standard:-IS 7098 Part I/88, IS 8130/2013, IS 5831/84, IS 3975/1999 etc. with latest up to date amendments Copper Armoured Cable: Voltage: 1100V Conductor:Stranded Class 2 Copper Conductor Insulation: XLPE as per IS 7098(Pt-1)/88, Latest Inner Sheath: Extruded PVC Type 'ST2' as per IS:5831/84 Armoure: Galvanised Steel Flat strip armour Outer Sheath: Extruded FR-LSH PVC Type 'ST2' as per IS:5831/84 Standard:Generally as per IS 7098 Part I/88, IS 8130/2013, IS 5831/84, IS 3975/1999 etc. with latest up to date amendmentsSupply, testing & Commissioning of XLPE insulated - Outer sheath Extruded FRLS medium voltage Armoured Aluminium cables as per the specifications, drawings & instruction of Engineer-in-charge and as per the instruction of the manufacturer. The cable shall be laid with saddaling in open manner on wall/slab from SFU to Main Panel / Main Panel to Distribution board / distribution board to distribution board. The unit rate shall include supply & laying of cables,Transportation from site store to place of installtion,unpacking the drum and return of drum to the site store. 4C X 16 sq.mm XLPE - FRLS Aluminium Armoured cable
Providing and Installing of Decorative Poles with LED Light on Fateh Sagar Periphery Area. 2201
Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth