Loading…
Loading…
2,844 results • Best match
SPL REPAIR OF OVERHEAD ACSR CONDUCTOR WITH UG CABLE, JUNCTION BOXES, LT PANELS AND CONNECTED ITEMS UNDER GE DINJAN
Material and Labour in repair, dismantling the all cable from panel, poles, MCB Main DBs taking out the cable loop stretching out the cable, carrying out end termination with new lugs, proper thimbling, fixing the joint kits connecting back to the new/existing panel board by means of nuts, bolts & washers of any size any type all as directed by engineer in charge. Note: (The work includes necessary excavation to take out the loop,and laying the cable, putting proper cable protection bricks using the old retrived bricks and refill the area properly and spreading any surplus soil (ii) The cost of Al lugs, joint kit shall be measured and paid separately under relevant items of schedule complete all as specified and directed.
PROVN OF ELECTRIC INFRASTRUCTURE AND ALLIED WORKS FOR 33/11 KV SUB STATION UNDER GE (A) JAISALMER
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade,earthed type of size 3 core 185 sq mm all complete all as specified and directed by Engineer-in-Charge.
CA NO.CWE BLY/GE (W)/61 OF 2026- 2027SPL REPAIRS REPLACEMENT OF ASBESTOS ROOF SHEET PURLIN RAFTER BRICK WORK CEILING PERIODICAL SERVICES AND CONNECTED WORKS IN BLDG NO P45 (1and2), T-104 OF ARO, P-7 and P-22 OF GE (WEST) AT BAREILLY
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4 core complete all as specified and directed.
Investigation Survey (On G.I.S. Basis) Construction of STP cum CoTreatment facilities (10.60 MLD STP 11.50 KLD co-treatment) I D of drains and structure rising main treated effluent line with SCADA etc in Dadri NPP Distt GB NAGAR
Supply and laying of unarmoured cable 6 mm2 core Flat PVC insulated for connection of LED to junction boxes.
Providing 1.00 MLD WSS to SIPCOT Industrial Park at Jayankondam in Ariyalur District
Laying the above cable as per I.E. rules
SPL REPAIR FOR ROOF TREATMENT FOR LEAKAGE/SEEPAGE IN AFFECTED MD ACCN OF JHANSI STN AND SPL REPAIR OF PROJECTOR ROOM OF WTSI INSTITUE UNDER AGE BR-II AT GE JHANSI
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 4 core complete.