Loading…
Loading…
8,120 results • Best match
Zonal contract for minor constructions, repair works and supply of building materials for service, Welfare buildings and drains inside inside Shell Factory including compound wall and between eastern side of Shell Factory and LOCO Bridge ROB i.e Canteen etc., & Furnishing factory & LHB including compound wall. for the year 2026-27 - (Shell and Furnishing factory)
Civil Work
Providing, supplying, designing and engineering, fabricating, transporting, installing, testing and commissioning of complete Gallery Interior Décor & Fit-out Works for the indoor science gallery “Ancient Indian Science Gallery” (approx. 415 Sqm fit-out area) on turnkey basis, excluding HVAC and civil works, comprising design detailing/shop drawings and setting-out/coordination; providing and laying heavy-duty commercial flooring including surface preparation, adhesive/primer, skirting and pathway/wayfinding markings; NO FALSE CEILING IN SCOPE; provide exposed ceiling surface preparation and paint finish; coordinate track lighting supports and exposed cable trays/raceways; providing MS stud framework feature walls/linings/false walls with boards including openings/cut-outs, access panels and concealed raceways; providing complete wall finishing including jointing/putty/primer and approved paint/texture finish; providing thematic cladding/backdrops/column boxing and trims with required service hatches; providing complete graphics package including printed panels/vinyl/UV prints with matte lamination and mounting hardware; providing acoustic treatment works for quiz/activity corner buffer; providing exhibition lighting system including tracks, track heads/accent spots, drivers, wiring, mounting, aiming/focusing and commissioning; providing internal gallery electrical works including protection, wiring/conduits, socket points for exhibit interfaces, earthing and testing; providing ELV infrastructure including conduits/raceways, Cat6 points, terminations/labeling (backbone by others); providing window/opening light control/blackout treatment as approved; complete testing & commissioning, snag rectification, documentation/O&M manuals, training and handover, including packing, transport, handling, protection, scaffolding/supports and consumables, complete in all respects with 12 months warranty.
Redevelopment of National Communications Academy-Technology (NCA-T) Campus, Ghaziabad (U.P.) SH: Construction of International Hostel, Trainees Hostel, Type-VII DG s Residence, Utility Building, Swimming Pool along with External Development (Civil, ... Horticulture work ). ...
Renovation of Exterior Elevation and Officers Cabins and works spaces and other miscellaneous works for FCI Zonal Office Building G plus 4, Chennai Civil and EM works
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/ structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3.Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Special renovation and rectification of existing old Electrical works in parity with Civil renovation works at Different locations of Pediatric Department under MJN main Hospital building, MJN MCH, Cooch Behar.
Dismentling the existing E.I. work by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC
Repair Renovation and facelifting of Divisional Office Building of CID Sopore including chequered Tile Path
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.