Loading…
Loading…
8,117 results • Best match
Construction of Sewage Treatment Plant Capacity 0.50 MLD and Sewer Network with Allied Civil Work) (Under Used Water Management Component under SBM (U) 2.0).
Construction of Sewage Treatment Plant of 0.50 MLD capacity based on MBBR Technology , including evolving of hydraulic & structural designs & drawings, planning, testing and commissioning of treatment facility. The Sewage Treatment Plant should be capable of treating domestic raw sewage having characteristics of BOD =350 mg/litre & suspended Solids =650 mg/litre and the characteristics of treated /disposable effluent should comply with the standards as per the norms of H.P. State Pollution Control Board i.e. PH = 6.5- 9, BOD ≤ 10 mg/litre, COD ≤ 50 mg/litre, TSS ≤ 50 mg /litre, Faecal Coliform (MPN /1000 ml) 100, N - Total N ≤ 10 mg/litre, NH4 - N ≤ 5 mg/litre. The scope of work includes construction of Inlet Chamber (1 No.), Screen Chamber (2 No.), Grit Channel (2 No.), Distribution Box (1 No.), MBBR (Moving Bed Bio Film Reactor), Sludge Drawing Bed , chlorine contact tank with required arrangement, Interconnectivity pipe of STP units & Effluent Pipe for disposal of treated waste, providing and installation of Electro - Mechanic Equipment’s with DMF, coiling & acccess loddor and Plant building , Fencing Panel around the STP yard Steel Gate Lab equipment complete in all respect with in all leads and lifts at site complete in all respect as per the entire satisfaction of Engineer-in-charge (as per chapter No. vi(a), vi(b), vi (c). 3 Months of successful trial run as per the provisions of Manual on Sewerage & Sewage Treatment published by CPHEEO Manual (Latest edition).
Civil works Plumbing works and Electrical works
Civil works
Civil and Electrical Repair of old false ceiling false ceiling in new Chemical and Biotechnology department building conference hall 5th floor and new Metallurgical and Materials department building conference hall dias room 5th floor at NIT Warangal
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Facility Management Services - LumpSum Based - Construction of New 33 11 KV Sub Station Mata Ji Masani Devi District Badaun; civil works; Consumables to be provided by service provider (inclusive in contract cost)
Facility Management Services - LumpSum Based - Construction of New 33 11 KV Sub Station Mata Ji Masani Devi District Badaun; civil works; Consumables to be provided by service provider (inclusive in contract cost)
Extention of Steel Cover Shed size 50x75 feet at sabzi Mandi Ferozepur City MC Ferozepur City Distt Ferozepur Civil and Electrical Works Work Code FZR2026-42
Extention of Steel Cover Shed size 50x75 feet at sabzi Mandi Ferozepur City MC Ferozepur City Distt Ferozepur Civil and Electrical Works Work Code FZR2026-42
Special Repair/Renovation of existing Circuit House Civil Station Bathinda. (Specialized Low Voltage Services)
Supply, Installation, Testing & Commissioning of UPS online 1 kva 800 Watts Tower UPS with Minimum 30 minutes battery backup. Operating Temperature Range 0 to 40 Degree @ 100% Load @ 50 Degree with 50% Load,Storage Temperature -15°C~60°C, Relative Humidity 0-95% No condensates, Acoustic Noise 40 dBA @ 1 Meter, Cooling Forced air cooling by the internal fans, Input Socket IEC C13, Output Socket IEC C14, No of output sockets 3 No's, Rated Input Voltage 208/220/230/240 Vac, Maximum working input voltage range 160 to 300 Vac @ 100% Load, 100 to 300 Vac @ 50% Load, Input Power Factor 0.99, Input THDi% 5%, Generator Set Yes 1.5 x UPS Capacity, Rated kVA 1000 VA, Rated kW 800 Watts, Load type Resistive load/ lagging load/ non-linear load/ transformer load/ lighting load, Load power factor range 0.5~1 lagging, Load Crest Ratio 3:1, Online Efficiency 88%, Rated Battery Voltage 36 Vdc, Battery Type VRLA (Valve Regulated Lead Acid Battery), 12VDC, Battery backup Back UP : 936VAH, Maximum charging current 10 Amps, ECO Mode Available, Communication (Independent SCI) Available, Intelligent Card slot (Independent SCI) Available, OVCD Available, EPO Function Available, Intelligent Fans Speed control Available, Auto restart function Available, Cold start Available. Complete in all respects as approved and desired by the Engineer in charge at site.