8,278 results • Best match
Repairs, restoration and renovation to the CHLD Building at MPA Harbour
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.
Construction work of 30 Judge's residence(G+05) in the old jail premises of civil court, Jamui
Providing and fixing M.S. pipe to I.S. 1239 (Heavy class) complete with all supports & fittings like, unions, couplings, bends, elbows, tees, offsets,reducers, flanges as per table 'E' etc. to complete the work as per the requirement at site including painting with one coat of primer after surface preparartion and two coats of synthetic enamel paint, cutting and making good the walls good complete. Pipe upto 40 mm dia threaded joints with holdtite, 50 mm dia and above should be welded joint ( all type ) ( internal works/External Works).
Construction of steel framing building G Plus 2 for advance manufacturing Robotics and Automation and advanced manufacturing Industry 4.0 and IIoT labs at NSUT Campus, Sector-3, Dwarka, New Delhi during 2026-27 Civil and Electrical work
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face# 1 and polymer (Service) coating on face# 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
General Repair/Maintenance Work (Civil, Carpentry, plumbing, Aluminium, Water proofing) of Trikuta and Kailash Hostels including Central Mess, Gym etc and Central Library and Administrative Block at SMVDU, Kakryal, Katra
All items covered by the J&K Schedule of Rates 2022 under Basic Rates, Builidng work and services (Civil work, Aluminium work, Carpentary work, water providing, painting work etc
GE/CHD/T-24/2026-27 MAINT AND MISC CIVIL REPAIR WORKS TO CERTAIN MD AND OTM ACCN AT HALLOMAJRA UNDER GE CHANDIGARH
Disconnecting existing tanks of capacity exc 250 ltr but not exc 500 ltr , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
STRUCTURAL REPAIRS TO VARIOUS BLDG INCLUDING REMOVAL OF VEGETATION FROM STRUCTURAL MEMBERS CERTAIN MISC CIVIL WORKS AT SPDC, WED, DSRV NSD MKD AREA UNDER GE (NW) MANKHURD.
M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 16 mts including scaffolding and safety measurements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of debris/mortar of demolition out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for rendering 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for Acrylic emulsion and applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces