Loading…
Loading…
4,827 results • Best match
REPAIR TO SECURITY WALL, FENCING, DRAIN AND OTHER MISC REPAIR WORKS IN AOR OF AGE BR-I UNDER GE (W) PATHANKOT
M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves(thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required and dismentaling of old UNSV kerb stone from any position complete all as specified and directed.
PROVN OF CENTRAL COOLING SYSTEM IN BLDG NO P-25 AT 25 WEU UNDER GE(EAST) LUCKNOW.
S&F Factory made uPVC prelem colour fixing type DGU (Doouble glazed Unit ) window with 6mm-12 airgap-6mm glass UPVC windows with SC value of 0.44 and U value of 1.71, transmission 54%) (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 112 x 52mm & sash 42x 68 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi- chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge.
REPAIR TO DRAINS, RETAINING WALLS, PARAPET WALLS, KERB STONE, CULVERTS, VIEW CUTTERS AND FENCING ETC UNDER AGE B/R-II GE (KH) YOL
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed.
GE/CHM-42/2026-2027 PROVN OF TILING, GRANITE TOP, CUP BOARD SHUTTER IN P 501 COOK HOUSE, CONSTR OF RAMP AT BLDG NO P 899 AND CERTAIN MINOR WORK UNDER AGE B/R II AT CHANDIMANDIR
Kitchen sink with drainage board made out of stainless steel sheet 1.0mm thick with plug, washers and wastes, overall size 915 x 460mm, bowl size 410x330x160mm incl fixing cantilever brackets and connection to union, pipe, fixed as in repair complete all as specified and directed.
Fisheries - Fisheries Complex Pannivelichira - Infrastructure development of GIFT hatchery - Sedimentation tank and Air conditioned packing shed - General Civil Work(Re-Tender)
9.147D.1:Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
M/R to Govt. residential Buildings under WDI at Porvorim SH- Urgent Construction of Septic Tank and Soak Pit including repairs with painting to GPC-7-2 Govt Quarter Building at Porvorim.
Providing and fixing rigid PVC S.W.R. (soil waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed:;110 mm dia