ADDITIONAL ROOM AT GROUND FLOOR WITH ATTACHED TOILET IN HOUSE NO. 207, TYPE-8, SECTOR-18, CHANDIGARH (E.I WORK) (IBM NO. W4/2026/26047).
DSR Item No. 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Construction of 33 KV Defence industrial Corridor deposit bay along with other associated Works at 132KV S/S Akrabad under E-400 KV Substation Division, Aligarh
Cutting Straightening, Bending, Laying 600 mm below in side ground and above ground of with 75x10 mm size) of M.S. flat and for earthing of main structure, Auxiliary strucutre, C.T., C.B., B.I., L.I., with by 50x6 and 25x6MS... and above by excavation of trenches its back filling, straightening, cutting, bending work also includes painting of M.S. earth strip above ground level with one coat of red oxide ...
Providing Fixing LED Street Light In Palkhi Tal At-Gursale palakhital and segaon dumala near bhima river corner Tal-pandharpur.
Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP).(9-2-3)
CONDEMNATION AND REPLACEMENT OF 146 ACs AT INMAS UNDER GE (I) R AND D DELHI
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Improvement in Quad Cable parameters by attending low insulation over Hubli Division.
2304.00 for cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with... an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, the work shall be carried out as per the instructions of Railway representative at site. (Supply ...
CONSTRUCTION OF TECHNICAL BUILDING 01 X 50 MT WITH AC PLANT AND 01 X 100 MT WITHOUT AC FOR UNHD UNDER GE 881 EWS
Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried... metre below normal ground level connected to galvanized earth strip of size (32x6)mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with ...