Loading…
Loading…
10,474 results • Best match
SITC Of IEI including electrical rewiring, wiring, repairing, maintenance and misc. Electrical work at Chief Engineer Office, Multistoried Zonal office Building at Madhuban Chowk, Rohini.
Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector
Construction of 33KV line and installation of 33/0.4KV, 1x1000KVA sub-station to provide power supply to LIC building at SS Road, Fancy Bazar under deposit work scheme under Fancy Bazar Electrical Sub-Division on Full Turnkey Mode
GI Strip for DTR Neutral Earthing
Comprehensive annual maintenance of Electrical Installation work of the Sidho Kanho Birsha University Buildings Purulia 11KV indoor Sub Station underground LT Medium Voltage 230V 415V Line Street Light etc at Purulia in the District of Purulia
Churchgate - Electrical (Power) work in connection with repairs & prevention of leakage in control tower.
Supply of material & installation of maintenance free earth electrode of length 3 meter, including earth enhancement material for earthing for each electrode & other accessories as per Drg. No. SDO/ RDSO/ E&B/001 and RDSO Spec No. RDSO/SPN/197 /2008, as per Annexure XVI.
Annual Civil and Electrical Maintenance works in Rajnagar Exploration Camp of Regional Institute V Bilaspur for 2 years FY202627
Electrical fault repairing work without material by deployment of (one electrician with valid electrical wiremanship certificate and minimum five year experience for maintenance of electrical installation for domestic and office work)as and when required for 2 year (1manpower per week)
Open Rate Contract for Face Lifting/Day to Day Maintenance of Golf Course (Electrical Work).
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.