Executive Engineer PWD(RandB)nagrota Jammu
Executive Engineer PWD RandB Divison Nagrota
Open Rate Contract for Face Lifting/Day to Day Maintenance of Golf Course (Electrical Work).
2026_PWDJK_312026_6
Short e-NIT No. 22 of 2026-2027/Nagrota Dated 09-06-2026
Open Tender
Electrical Works
365 days
Executive Engineer PWD(RandB)nagrota Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Yes
Executive Engineer PWD RandB Divison Nagrota
₹28,000
Yes
10 Jun 2026
10 Jun 2026
19 Jun 2026
10 Jun 2026
18 Jun 2026
10 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Repair of 200 KVA Servo Stabilizer (Detailed Item Description): Repair, servicing, and complete overhauling of 200 KVA Servo Stabilizer including body work with strengthening/repair of main frame, fabrication and fixing of inbuilt panel for bypass arrangement comprising of 400 Amp bypass switch and 300 Amp contactor. The scope shall also include replacement /repair of internal components such as arm bush, top bush, carbon brushes, copper reaping arm (35 sq.mm), and central cords of all phases.Further, the work includes rewinding of all three phases (as required), repair/servicing of buck-boost transformer, oil topping (if required), proper insulation, alignment, testing, and commissioning of the stabilizer.The item also includes complete dismantling, loading, transportation to workshop, unloading, repair, re-installation at site, testing, and commissioning, along with all consumables, labour, tools & tackles required for satisfactory operation of the system. | |||||
| 2Dismantling of existing 11 mtr electric pole, shifting to new approved location, excavation of pit, providing and laying PCC (1:3:6) foundation, erection in proper alignment, refixing of all existing fittings, backfilling, ramming and curing, complete in all respects as per directions of Engineer-in-Charge. | |||||
| 3Repair of installed automatic dome sensor door by way of replacement of defective controlling transformer/motor, belt, sensors, and servicing including proper balancing of doors, greasing of belt and allied components, complete in all respects as per directions of Engineer-in-Charge. | |||||
| 4Repairing Cable with Cable sleeves with cotton blade, Pvc tape, tube joint, thimbles, Joint Kit etc as per requirement at site and as per the instructions of Engineer-in-Charge. | |||||
| 5Repair of non-functional 20 KVA Capacitor Bank by way of replacement of defective condenser (capacitor unit) including allied works i.e. a, Dismantling of the existing defective capacitor (condenser) from the capacitor bank panel. b, Supply and installation of suitable 20 KVA rated capacitor unit (as per existing system specification). c, Checking and tightening of all electrical connections, contactors, fuses, and terminals. d, Replacement of minor accessories (lugs, thimbles, nuts/bolts, insulating materials, etc.) as required. e, Testing of capacitor bank for proper functioning, power factor improvement, and load balancing. f, Recommissioning of the capacitor bank after repair. g, Disposal of unserviceable capacitor as per norms. | |||||
| 6Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group-A | |||||
| 7Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required (Partially laid conduit) | |||||
| 8Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC casing & capping, with modular switch, modular plate, suitable PVC box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required | |||||
| 9Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group A | |||||
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. | 1 | No. | 545 | ₹545 |