Loading…
Loading…
10,912 results • Best match
For various running electrification works under full deposite head in EDD-Shahajahanpur under EDC-Shahajahanpur, MVVNL.
UNDER GROUND LAYING OF FOLLOWING CABLE IN SINGLE CIRCUIT ON RIVER SAND TO DOUBLE POLE SITUATED AT BOTH SIDES OF ROAD COMPLETE IN ALL RESPECT. MINIMUM DEPTH SHOULD BE 0.75 METER AND CABLE SHOULD BE COVERED BY BRICKES FROM THREE SIDES. ALONG WITH FILLING OF 04 NOS. CABLE JOINING KITES.
Renovation of EI and fans including security light, Gate light, Earthing etc in Canteen of PTC, Darbhanga.
R Maint of chemical earthing and cleaning of septic tank manholes and sewerage line at 42 AR
Repair/maint of chemical earthing for VSAT system:- Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
SPL REPAIR / REPLACEMENT OF OLD UNSERVICEABLE EARTHING OF OTM ACCN AND MISC WORK UNDER GE (NORTH) BINNAGURI
S&F in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required using 4mm dia GI or steel wire complete all as specified and as directed.
Refurbishing of existing plate earthing system with Earth-mat in lower yard at 110 kV Substation Koppam
C-202526-3027-3 Conveying of precast RCC slabs of various size manually from stacking place to laying place up to 100m lead etc. complete and laying carefully in position without damaging the edges of slabs as well as cable trench side wall as per directions of Engineer- in - charge
SPECIAL REPAIR TO LIGHTNING PROTECTION SYSTEM ALONGWITH EARTHING AND ALLIED WORKS AT MCEME UNDER GE MCEME SECUNDERABAD
Dismantling & taking down old U/S earthing & M&L for earthing complete with galvanised steel earth plate 600 mm x 600 mm x6 mm thick elecrode and 4 mm dia galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust of minmum qty - 40 Kg and common salt of minmum qty - 40 Kg to a packed thickness of 15 cm on all sides of electrode as specified and connected to GI wire of dia 4 mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work and excavation, PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, with one handle for lifting made out 6mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm GI tubing medium grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.