Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC R N COLONY PO BIRPARA DIST ALIPURDUAR W B PIN 735204 | ALIPURDUAR | WEST BENGAL | 735204 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹41.7 L+₹4.4 L (11.8%)Rejected-Finance | L2 | Rejected-Finance Lowest 02 bidder | |
| 3 | L3₹42.0 L+₹4.7 L (12.6%)Rejected-Finance | L3 | Rejected-Finance Lowest 03 bidder | |
| 4 | L4₹42.5 L+₹5.2 L (14.0%)Rejected-Finance | L4 | Rejected-Finance Lowest 04 bidder | |
| 5 | L5₹42.6 L+₹5.4 L (14.3%)Rejected-Finance 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L5 | Rejected-Finance Lowest 05 bidder |
| Sl No | Description | Qty | Unit | flexpro construction company L2 | CENTRAL ENGINEERING WORKS L7 | N K Construction L6 | M/S SINHA ENTERPRISE L5 | M/S NIKITA ENGINEERING CO L1 | M/S S.K.DAS L4 | ANUP ENGINEERING WORKS L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 of SSR Part-I including necessary excavation and earth work, PCC 1:3:6 type C-1 with 50mm thick pre-cast RCC cover 1:2:4 type B-1 cover slab reinforced with 8 mm dia TMT bar @ 15cm C/C both ways with suitable handle of 10mm dia MS rod including providing charcoal or coke & common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore (light grade GI watering pipe wire mesh, aluminium lugs complete in all respect GI earth wire protected by 15mm bore GI pipe and other end connected with main switch/ earth test pont, including dismantling old unserviceable earth pit complete all as specified and as directed. | 425 | Each | 7,000 ₹29,75,000 | 7,050 ₹29,96,250 | 7,350 ₹31,23,750 | 7,180 ₹30,51,500 | 6,400 ₹27,20,000 Lowest | 7,200 ₹30,60,000 | 6,950 ₹29,53,750 |
| 2.00 | S&F in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required using 4mm dia GI or steel wire complete all as specified and as directed. | 200 | RM | 70 ₹14,000 | 80 ₹16,000 | 80 ₹16,000 | 78 ₹15,600 | 68 ₹13,600 Lowest | 78 ₹15,600 | 88 ₹17,600 |
| 3.00 | S&F 15 mm nominal bore steel water tubes, 'light grade' fixed on walls, floors and in ground etc for GI wire protection fixed on porcleain/ post insulator with necessary clamps/nut bolts as required complete all as specified and as directed. | 175 | RM | 188 ₹32,900 | 180 ₹31,500 | 200 ₹35,000 | 190 ₹33,250 | 175 ₹30,625 Lowest | 205 ₹35,875 | 215 ₹37,625 |
| 4.00 | S&F test point terminal block made of gun metal or phosphorous bronze, size 75mm x 75mm x 25 mm thick, drilled and screwed including 3 Nos. 8 mm dia. 25 mm long hexagonal head screws, including MS box 2 mm thick of suitable size for protection of test point terminal, including dismantling of old unserviceable test point complete all as specified and as directed. | 425 | Each Job | 1,900 ₹8,07,500 | 2,500 ₹10,62,500 | 2,150 ₹9,13,750 | 1,890 ₹8,03,250 | 1,550 ₹6,58,750 Lowest | 1,890 ₹8,03,250 | 2,000 ₹8,50,000 |
| 5.00 | M&L construction of PCC earth cover of size 300x300 (internal dimension) as shown in electrical plate No 05 of SSR Part-I, any type C-1 (1:3:6) 20mm graded aggregate including 50mm thick pre-cast RCC cover slab type B1 1:2:4, reinforced with 8mm dia TMT bar @ 15cm center to center both ways with suitable size handle of 10mm dia MS Rod including necessary formwork as required including dismantling/ taking out old unserviceable, earth pit cover complete all as specified and as directed. | 170 | Each Job | 2,000 ₹3,40,000 | 2,200 ₹3,74,000 | 2,000 ₹3,40,000 | 2,120 ₹3,60,400 | 1,800 ₹3,06,000 Lowest | 1,980 ₹3,36,600 | 1,990 ₹3,38,300 |
Tender Value
₹36.7 L
EMD Value
₹73,440
Closing Date
11 Jul 2026, 6:00 pmClosed
GE (North) Binnaguri
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
SPL REPAIR / REPLACEMENT OF OLD UNSERVICEABLE EARTHING OF OTM ACCN AND MISC WORK UNDER GE (NORTH) BINNAGURI
2026_MES_773836_1
8701 / 50 / 2026-27 / 08 / E8
Open Tender
Civil Works
Item Rate
180 days
Binnaguri cantonment
As per Tender Document
8 documents required · 8 mandatory
₹500
GE (North) Binnaguri
₹73,440
Yes
30 Jul 2026
20 Jun 2026
13 Jul 2026
20 Jun 2026
11 Jul 2026
4 Jul 2026
20 Jun 2026 - 27 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 of SSR Part-I including necessary excavation and earth work, PCC 1:3:6 type C-1 with 50mm thick pre-cast RCC cover 1:2:4 type B-1 cover slab reinforced with 8 mm dia TMT bar @ 15cm C/C both ways with suitable handle of 10mm dia MS rod including providing charcoal or coke & common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore (light grade GI watering pipe wire mesh, aluminium lugs complete in all respect GI earth wire protected by 15mm bore GI pipe and other end connected with main switch/ earth test pont, including dismantling old unserviceable earth pit complete all as specified and as directed. | 425 | Each | - | - |
| 2 | S&F in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required using 4mm dia GI or steel wire complete all as specified and as directed. | 200 | RM | - | - |
| 3 | S&F 15 mm nominal bore steel water tubes, 'light grade' fixed on walls, floors and in ground etc for GI wire protection fixed on porcleain/ post insulator with necessary clamps/nut bolts as required complete all as specified and as directed. | 175 | RM | - | - |
| 4 | S&F test point terminal block made of gun metal or phosphorous bronze, size 75mm x 75mm x 25 mm thick, drilled and screwed including 3 Nos. 8 mm dia. 25 mm long hexagonal head screws, including MS box 2 mm thick of suitable size for protection of test point terminal, including dismantling of old unserviceable test point complete all as specified and as directed. | 425 | Each Job | - | - |
| 5 | M&L construction of PCC earth cover of size 300x300 (internal dimension) as shown in electrical plate No 05 of SSR Part-I, any type C-1 (1:3:6) 20mm graded aggregate including 50mm thick pre-cast RCC cover slab type B1 1:2:4, reinforced with 8mm dia TMT bar @ 15cm center to center both ways with suitable size handle of 10mm dia MS Rod including necessary formwork as required including dismantling/ taking out old unserviceable, earth pit cover complete all as specified and as directed. | 170 | Each Job | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
Tender.pdf
Tender Documents • 0.94 MB
BOQ_866482.xls
BOQ • 0.37 MB
Sch.pdf
Additional Documents • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .