Loading…
Loading…
10,156 results • Best match
Design, Manufacturing, Supply & Installation, Commissioning and proveout of 15T Capacity Electric Overhead Travelling Crane. Detailed Technical literature and Scope of work as per specification Sr.DME/SC/EOT-15/05T/Remote/2023 Rev-0 attached
Machine (Y) Description :Design, Manufacturing, Supply & Installation, Commissioning and proveout of 15T Capacity Ele ctric Overhead Travelling Crane. Detailed Technical literature and Scope of work as per specification Sr.DME/ SC/EOT-15/05T/Remote/2023 Rev-0 attached. [ Warranty Period: 24 Months after the date of delivery ] ] Consignee SSE/C&W/SNF, SCR Telangana 2.00 Numbers Product Inspection:Stage 1: Raw Material Inspection as per Annexure-K (100% of PO Inspection Details Qty ), Stage 2: In Process Inspection as per Annexure-K (100% of PO Qty )
Electric repair work at residential quarter J/1/4 Pratapnagar Under CSD IV at Udaipur
Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required.
SPL REPAIR / REPLACEMENT OF EXTERNAL ELECTRIFICATION, LT PANELS, LT POLES, STREET LIGHTS, FLOOD LIGHTS AND CONNECTED WORK AT CIV LINES NAGPUR AND PROVISION OF BOLLARD LIGHTS, POST TOP LATERN AND BLDG SEURITY LIGHTS AT MDC KAMPTEE UNDER GE KAMPTEE.
M&L for maint free safe earthing system burnished copper earthing electrolyte grade 5 centimeter dia closed with 5 centimeter electrolyte plate set of four separate electrode to be used as grid earthing each pit complete with 01 Number approved/CPRI tested copper bonded (copper cladded earth rod with C microns of copper cladding) earth rod with 1.7 centimeter mm dia 3.0 centimmetr long electrode buried in ground to bore holes 120 mm dia vertically to a depth not less than 3500 mm deep blow ground level or L shape in case of Rocky condition (2 ft deep and 8 ft horizontol) with top edge of earth electrode at a depth not less than 500mm below normal ground level, provision of copper bus bar of size 200mm x 25mmx6mm for inter connection with copper earth lead strip 25mm x 3mm and further connected to test point terminal block alongwith the protection pipe of size 25mm bore med grade all as directed. each earth pit shall include minimum 50kg (two bags of 25kg each) NABL lab Certified back fill compound and 6 kg (two container of 3kg Each) NABL Lab Certified conductive gel compound for filling bore holes with mother soil mixed in 1:3 ratio (one part of back fill compound and three part of mother soil), so as to achieve earth resistance below 1 Ohm including exacavation of polypit chamber with polyplastic pit cover (cost of poly pit chamber with polyplastic pit cover shall be deemed to be included in the rate quoted) complete all as specified and as directed. Note : (a) Copper strip beyond test point shall be measured and paid separately (b) Contractor shall give guarantee of minimum 5 yrs for the earting carried out by him. (c) The rate quoted is inclusive of test point made of phosphorous bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long brass nuts and bolts complete all as directed. (d) Any other fittings /fixtures if technically required for archieving desired results (if not included above) shall be provided by contractor without any extra cost to the Govt. (e) On testing after completion if the desired resistenance i.e below 1 Ohm is not obtained the contractor shall redo the earthing without any extra cost of department.
REPAIR AND REPLACEMENT OF UNSERVICEABLE INTERNAL WIRING INCLUDING CONNECTED ITEMS, REPAIRING OF SUMMER/WINTER APPLIANCES AND GENERAL MAINTENANCE OF INTERNAL ELECTRIFICATION AT SECTOR 28,29,30 RCMA AND OTHER AREAS AT CHANDIGARH
Material and labour for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth electrode connected connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 incl PCC earth pit with CI frame and RCC cover including testing and dismantling ,taking down old unser earthing complete all as specified and directed Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, watering pipe, earth lead protection pipe, porcelain insulator,PCC earth Pit, RCC cover, funnel with wire mesh shall be deemed to be included in the unit rate quoted.
Supply Replacement Testing and Commissioning of damaged/outdated feeder pillar i/c miscellaneous electric work at DDA Roshanara club
SRTC of indoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP54 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for Gym, health club, swimming pool , admin building, badminton court, gust house and AC of club , card room , billyyard and bar ) A) INCOMER i) 400 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-3 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 250/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARS i) 600 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type ) C) OUTGOINGS i) 125 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 8 Nos.
Custom Bid for Services - The Work of 11 KV Line Strengthning and cabeling works at various 33/11 KV substations in Business Plan 2026-27 on Semi Turn-key Basis under the area of Electricity Distribution Division, Saifai Similar Category Operation ... and Installation of ... and Installation of ...
Custom Bid for Services - The Work of 11 KV Line Strengthning and cabeling works at various 33/11 KV substations in Business Plan 2026-27 on Semi Turn-key Basis under the area of Electricity Distribution Division