Providing Internal Electrification Works in Administrative building Gomati Hostel Baramura Hostel and Forest Rest Gym alongwith outdoor lighting fixtures in the Tripura Forest Training Division Hatipara Gandhigram under ELEMENT Project
Design, fabrication, supply, installation, testing & commissioning of floor-mounted indoor-type partially type-tested panel (IP 43) (manufactured by a CPRI-approved electrical panel manufacturer) of the following specifications. ENCLOSURE: The enclosure should be fabricated from CRCA (Cold Rolled Close Annealed) sheet steel, with hinged doors provided at both the front and rear. Cable entry and outgoing connections shall be from the bottom/Top through a gland plate. The enclosure body, doors, and other parts shall be made from 2.0 mm thick CRCA sheets, while the gland plate shall be 3.0 mm thick. The entire enclosure shall be subjected to a seven-tank pre-treatment process and finished with a minimum 60-micron thick powder coating of light grey color, shade RAL 7032 (simens Grey). AMF CONTROLLER:- The system shall operate on 24V DC power and include Automatic Mains Failure (AMF) and Automatic Transfer Switch (ATS) functions. It shall have CAN bus and serial communication facilities. The device shall provide protection as per ANSI codes: 27P (under voltage), 59 (over voltage), 81U (under frequency), 81O (over frequency), 50TD (time delay overcurrent), 32F (forward power), 32R (reverse power), 14 (under speed), 12 (over speed), and 51 (inverse time overcurrent) . BREAKER DETAILS:- Four (04) numbers of ACB incomers (two for feeders, one for DG and one for outgoing ) shall be provided, each rated at 200A, 4-pole, with a breaking capacity of 50kA (Icu = Ics = Icw for 1 second). All ACBs shall be of EDO (Electrical Draw-Out) type and equipped with a microprocessor-based protection release. Including , three (03) numbers of undervoltage (UV) coils rated at 415V AC & 200A,TPN Motorised changeover. (L&T/SOCOMEC) METERING & INDICATIONS:- The metering and indication system shall include four (04)no. multifunction meters capable of measuring voltage, current, frequency, power factor, kilowatt, kilovolt-ampere, energy in KWh (old), on and run hours, with site-selectable kWh/kVAh display, accuracy class 0.5, auxiliary supply of 80–300V AC/DC, LED display, and RS-485 communication port. One (01) VAF meter shall be provided for measuring voltage, current, frequency, and power factor, with class 0.5 accuracy, auxiliary supply of 80–300V AC/DC, and 96x96 mm LED display. One (01) DC analog voltmeter of range 0–30V DC (MI type) and one (01) DC analog ammeter of range 0–30A DC (MI type) shall be provided. Indication lamps shall be provided as follows: four (04) red, four (04) yellow, and four (04) blue lamps operating at 230V AC; one (01) red and one (01) green lamp operating at 230V AC; four (04) red, four (04) green, four (04) amber, and one (01) white lamp operating at 24V DC. All indication lamps shall be of cluster LED type of 22.5mm dia. CT DETAILS:-Three (03 nos. of Current Transformers (CTs) shall be provided, each having a rating of 200A/5A, 10VA, accuracy class . BATTERY CHARGER:- One(01) no. of battery charger shall be provided of CCCV type. ( Lauritz Knudsen /ABB/ Legrand/Siemens/MICROPOWER/NHP). BUS BAR DETAILS:- Two (02) sets of incomer power busbars, one (01) set of outgoing power busbar, and one (01) set of common power busbar i/c one (01) set of Earthing busbar shall be provided. Each busbar shall be rated at 200A, TPN, and made of EC-grade aluminium, designed considering a current density of 1.0A/sq.mm. The busbar system shall include colour-coded heat shrink sleeves and suitable insulators for proper phase identification, insulation, and safety. CONTROL CIRCUIT ACCESSORIES:- The control circuit accessories shall consist of push button actuators (green, red, and emergency type), TNC switches, contact block modules (NO and NC), control relays with relay bases, selector switches,MCB as suitable for above installation
RESTORATION AND REPAIR OF ELECTRIC FURNACE NO. 4 WITH ALLIED WORKS AT COSSIPORE MAHASMASHAN
PLUMBING WORKS (A)-(III) CPVC PIPE WORKS AND FITTINGS (A)-(III) CPVC PIPE WORKS AND FITTINGS Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories,specials viz. socket,bend,tee,union,cross,elbo,nipple,longscrew, reducing socket,reducing tee, short piece etc.fitted with holder bats clamps, including cutting pipes,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11 (Dia) 50 mm
REPAIR/ MAINT OF INTERNAL ELECTRIFICATION INCLUDING LT PANELS AND UG CABLES AT ABHM, GE NEW DELHI OFFICE COMPLEX AND ABHM ANNEXE UNDER GE NEW DELHI
M&L in replacement for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected togalvanised iron (wire 4mm) as earthinglead lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 5 of SSR Pt-I including RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit including excavation and earth work in any type of soil and testing on completion etc complete all as specified and directed. NOTE: GI earth strip exceeding 7.5m will be measured and paid separately
Construction of 200 Capacity auditorium at Central staff training and research institute(CSTARI) campus, EN 81,Saltlake Kolkata 700091 including interior acoustic Treatment, external GRC elements & art, providing Internal electrical installation (IEI) power points, lightening conductors, fire alarm system, CCTV, audio video system, stage furnishing & stage Lighting system. SH: Geotechnical/Soil investigation at the proposed construction site at CSTARI during the year 2026-27.
MAINT REPAIR TO EARTHING SYSTEM OF VARIOUS INSTALLATIONS, FIRE FIGHTING SYSTEM SUCH AS REPAIR TO HYDRANTS, PUMP SETS, VALVES, SENSOR PANELS, HOSE CABINETS ETC AT VARIOUS LOCATIONS AND OTHERS ALONG WITH MISC WORK AT HQ SAC UNDER GE AF TRIVANDRUM
M&L in replacement of earthing complete with GI earth plate electrode 60cmx60cmx6mm thick,buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to Galvansed Iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR Part-I connected to earting test point all as specified or indicated complete with excavation & Earth work PCC Pit in cement concrete 1:2:4 type B1 with 50mm thick RCC cover (grade M-15 ) having suitable Handle (10mm MS Rod ) 20mm dia GI medium grade watering with GI funnel with wire mesh 40mm bore GI pipe (light grade ) for the protection of earth lead conductor all as directed and testing on complection as specified and as directed .
REPAIR AND REPLACEMENT OF UNSERVICEABLE INTERNAL WIRING INCLUDING CONNECTED ITEMS, REPAIRING OF SUMMER/WINTER APPLIANCES AND GENERAL MAINTENANCE OF INTERNAL ELECTRIFICATION AT SECTOR-24,37,38,42 AND OTHER AREAS AT CHANDIGARH
Material and labour for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth electrode connected connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 incl PCC earth pit with CI frame and RCC cover including testing and dismantling ,taking down old unser earthing complete all as specified and directed. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, watering pipe, earth lead protection pipe, porcelain insulator,PCC earth Pit, RCC cover, funnel with wire mesh shall be deemed to be included in the unit rate quoted.