Loading…
Loading…
10,151 results • Best match
INTERNAL REPARING, RENEWAL, RENOVATION FASAD LIGHTING UPGRADATION WORK & INTERNAL RENOVATION WITH ELECTRIFICATION WORK OF DR. B.R. AMBEDKAR MEMORIAL HOSPITAL, AT RAIPUR , DISTT. RAIPUR.(DN. NO.2, RAPIUR).(DEPOSITE WORK) (Without Escalation and Bonus)
Supplying and laying of Cat 6 outdoor cable solid annealed Bare copper Conductor ,LLD PE/PE sheath Material For Video Power and audio Communication with laying cable Underground with suttable size Pvc conduit /Casing Caping and other accessories as per requirment.
SPECIAL REPAIR OF EXTERNAL ELECTRIC SUPPLY INCLUDING LT PANELS AND CONNECTED ACCESSORIES FOR HQ 138 WORKS ENGRS UNDER GE 865 EWS, LEH
Material and labour for Sand cushioning to under ground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, 2009. complete all as specified and/or as directed by Engr-in-Charge. Note : Punned thickness only will be measured and paid.
Rate Contract for Electric maintenance works in Non Residential buildings at District headquarter Bhilwara
P & F 1.2 mm thick Hot dipped galvanized boxes with brass earthing terminal of following sizes (nominal size) in recessed/surface as required.
Design, Supply, Erection, Testing & Commissioning of Railway Electrification Work of 2x25 kV AC OHE Traction System along with Boundary Sectioning Posts (BSPs), Sub-Sectioning Posts (SSPs) between Sahjanwa (Excl.) to Bansgaon (Incl.) section in connection with Sahjanwa - Dohrighat new BG line project in N.E. Railway of Lucknow Division
Supply and Erection of Materials for Each Internal and External Lighting of Switching Station Building (SP/SSP). 2 1(d) Design and Drawings for Switching Each 2.00 82785.00 165570.00 Stations (SSP/BSP) (2x25 kV Traction System) 3 6(i) Supply (without Insulator) of 25 kV Each 4.00 11791.00 47164.00 Drop-Out Fuse Switches for Auxiliary Supply Transformers. 4 6(i) Erection of 25 kV Drop-Out Fuse Each 4.00 853.00 3412.00 Switches for Auxiliary Supply Transformers. 5 7(c) Supply of 50kV/66 kV Termination Each 21.00 14873.00 312333.00 with Disc Insulator with Adjuster. 6 7(c) Erection of 50kV/66 kV Termination Each 21.00 554.00 11634.00 with Disc Insulator with Adjuster. 7 7(f) Supply of 50/66 kV Termination with Each 21.00 13683.00 287343.00 Disc Insulator without Adjuster. 8 7(f) Erection of 50/66 kV Termination Each 21.00 554.00 11634.00 with Disc Insulator without Adjuster. 9 8(b) Erection of a Solid Core Suspension Each 60.00 636.00 38160.00 (9 Tonne) Insulator. 10 8(b) Supply (without Insulator) of a Solid Each 60.00 1594.00 95640.00 Core Suspension (9 Tonne) Insulator. CAO-C-NER-ELECTRICAL/NORTH EASTERN RLY 11 8(c) Erection of Materials (including Each 18.00 1477.00 26586.00 Insulator) for Termination of Copper Cross Feeder Wire. 12 8(c) Supply (other than insulators) of Each 18.00 7096.00 127728.00 Materials (including Insulator) for Termination of Copper Cross Feeder Wire. 13 17(d) Supply of 150 AH, 110 V Low Set 2.00 246315.00 492630.00 Maintenance Lead Acid (LMLA) Batteries Set with 2 nos. of Suitable Battery Charger. 14 17(d) Installation of 150 AH, 110 V Low Set 2.00 18871.00 37742.00 Maintenance Lead Acid (LMLA) Batteries Set with 2 nos. of Suitable Battery Charger. 15 60(a) Manning of Switching Stations Each/month 12.00 64529.00 774348.00 (SP/SSP) Total 2587978.00 Item- 2 Section-8B: Cement and Reinforced Concrete S No. Item No Description of Item Unit Qty Rate Amount 1 2(c) Construction of Concrete for cum 535.00 2038.00 1090330.00 Foundation & Trench in other than Hard Soil & Rock 2 2(c) Supply of Concrete for Foundation & cum 535.00 4698.00 2513430.00 Trench in other than Hard Soil & Rock. 3 2(d) Construction of Reinforced Concrete cum 56.00 2492.00 139552.00 for Foundation & Trench. 4 2(d) Supply of Reinforced Concrete for cum 56.00 5481.00 306936.00 Foundation & Trench. 5 2(g) Construction of Plastering of Brick Sqm 381.00 83.00 31623.00 Work. 6 2(g) Supply of Plastering of Brick Work. Sqm 381.00 87.00 33147.00 7 2(j) Supply and construction of Brick cum 269.08 5515.00 1483976.20 Work in Foundation Plinth, Retaining Wall and Drainage. 8 2(m) Earth Work in Excavation and Filling cum 5000.00 174.00 870000.00 including Compaction (In Normal Soil). Total 6468994.20 Item- 3 Section-8C: Other Items (All commodities) S No. Item No Description of Item Unit Qty Rate Amount 1 3(i) Spreading of Ballast/Gravel in the cum 180.00 17.00 3060.00 Switch Yard. 2 3(i) Supply of Ballast/Gravel in the Switch cum 180.00 1617.00 291060.00 Yard. Total 294120.00 Item- 4 Section-8D: Insulator S No. Item No Description of Item Unit Qty Rate Amount 1 4(e) Erection of 25 kV Support Insulator. Each 26.00 340.00 8840.00 2 4(e) Supply of 25 kV Support Insulator. Each 26.00 7776.00 202176.00 Total 211016.00 Item- 5 Section-9A: Steel Items S No. Item No Description of Item Unit Qty Rate Amount 1 11(a) Supply of Fabricated & Galvanized MT 45.00 135237.00 6085665.00 Gantries/Portal structure for TSS & Switching Stations. 2 11(a) Erection of Fabricated & Galvanised MT 45.00 6201.00 279045.00 Gantries/Portal structure for TSS & Switching Stations. CAO-C-NER-ELECTRICAL/NORTH EASTERN RLY 3 11(c) Supply of Fabricated & Galvanized MT 4.00 135062.00 540248.00 small parts steel for TSS & Switching Stations. 4 11(c) Erection of Fabricated & Galvanized MT 4.00 4457.00 17828.00 small parts steel for TSS & Switching Stations. 5 12(a) Erection of Earth Electrode Each 38.00 2472.00 93936.00 6 12(a) Supply of Earth Electrode Each 38.00 3661.00 139118.00 7 12(b) Supply of Earth Leads 75mm X 8mm Metre 325.00 341.00 110825.00 Mild Steel Laid in the Ground. 8 12(b) Erection of Earth Leads 75mm X Metre 325.00 141.00 45825.00 8mm Mild Steel Laid in the Ground. 9 12(c) Supply of Earth Leads 50mm X 6mm Metre 660.00 167.00 110220.00 Mild Steel Laid in the Ground. 10 12(c) Erection of Earth Leads 50mm X Metre 660.00 101.00 66660.00 6mm Mild Steel Laid in the Ground. 11 12(f) Erection of 8/6 SWG G.I. Wire for Metre 780.00 32.00 24960.00 Earthing. 12 12(f) Supply of 8/6 SWG G.I. Wire for Metre 780.00 35.00 27300.00 Earthing. 13 12(g) Erection of 32mm Dia MS Rod for Metre 620.00 41.00 25420.00 Earth Mat. 14 12(g) Supply of 32mm Dia MS Rod for Metre 620.00 525.00 325500.00 Earth Mat. 15 13(a) Erection of Earth Screen Wires Metre 275.00 30.00 8250.00 16 13(a) Supply of Earth Screen Wires Metre 275.00 372.00 102300.00 17 14(a) Supply of Fencing Panels at Sub- Metre 260.00 2561.00 665860.00 Stations (TSS/BSP/SSP) 18 14(a) Erection of Fencing Panels at Sub- Metre 260.00 134.00 34840.00 Stations (TSS/BSP/SSP) 19 14(b) Erection of Fencing Upright at Sub- MT 3.30 5996.00 19786.80 Stations (TSS/BSP/SSP) 20 14(b) Supply of Fencing Upright at Sub- MT 3.30 91778.00 302867.40 Stations (TSS/BSP/SSP) 21 14(c) Erection of Gates. Metre 10.50 413.00 4336.50 22 14(c) Supply of Gates. Metre 10.50 2432.00 25536.00 23 14(d) Erection of Anticlimbing Device at Metre 250.00 13.00 3250.00 Sub-Stations (TSS/BSP/SSP). 24 14(d) Supply of Anticlimbing Device at Sub- Metre 250.00 257.00 64250.00 Stations (TSS/BSP/SSP). Total 9123826.70 Item- 6 Section-9B: Aluminium Items S No. Item No Description of Item Unit Qty Rate Amount 1 19(b) Supply of 38.25 mm dia (865 sq.mm) Metre 200.00 547.00 109400.00 AAC Bull Conductor 2 19(b) Erection of 38.25 mm dia (865 Metre 200.00 17.00 3400.00 sq.mm) AAC Bull Conductor 3 37(a) Erection of Tubular Aluminium Metre 356.00 107.00 38092.00 Busbars 50mm (O/D) x 39mm (I/D) 4 37(a) Supply of Tubular Aluminium Busbars Metre 356.00 1153.00 410468.00 50mm (O/D) x 39mm (I/D) 5 37(e) Supply of All Aluminium 25 kV Feeder Kilometre 1.50 285410.00 428115.00 / Return Conductor (Single Spider) 6 37(e) Erection of All Aluminium 25 kV Kilometre 1.50 5082.00 7623.00 Feeder / Return Conductor (Single Spider) Total 997098.00 Item- 7 Section-9C: Copper Items S No. Item No Description of Item Unit Qty Rate Amount 1 12(h) Erection of Copper Strips for Metre 56.00 124.00 6944.00 Equipment Earthing CAO-C-NER-ELECTRICAL/NORTH EASTERN RLY 2 12(h) Supply of Copper Strips for Metre 56.00 1050.00 58800.00 Equipment Earthing 3 38(b) Supply of Copper Feeder Wire Kilometre 0.50 2028872.00 1014436.00 (37/2.25 mm HDBC) 4 38(b) Erection of Copper Feeder Wire Kilometre 0.50 5082.00 2541.00 (37/2.25 mm HDBC) Total 1082721.00 Item- 8 Section-10A: Equipment's S No. Item No Description of Item Unit Qty Rate Amount 1 21(c) Erection, Testing and Commissioning Each 4.00 463350.00 1853400.00 of 16.5 MVA, 55 kV/27.5 kV, 50 Hz Auto Transformer. 2 21(c) Supply of 16.5 MVA, 55 kV/27.5 kV, Each 4.00 14294301.00 57177204.00 50 Hz Auto Transformer 3 24(e) Erection, Testing & Commissioning of Each 2.00 27483.00 54966.00 2x25 kV Control & Relay Panel, for SSP (SCOTT Connected/ V- Connected). 4 24(e) Supply of 2x25 kV Control & Relay Each 2.00 5940609.00 11881218.00 Panel, for SSP (SCOTT Connected/ V- Connected). 5 51(b) Erection of 25 kV Double Pole Each 4.00 13868.00 55472.00 Vacuum Circuit Breaker 6 51(b) Supply of 25 kV Double Pole Vacuum Each 4.00 999683.00 3998732.00 Circuit Breaker 7 51(c) Erection of 25 kV Single Pole Vacuum Each 2.00 6607.00 13214.00 Interrupter. 8 51(c) Supply of 25 kV Single Pole Vacuum Each 2.00 435974.00 871948.00 Interrupter. 9 51(d) Erection of 25 kV Double Pole Each 6.00 8996.00 53976.00 Vacuum Interrupter. 10 51(d) Supply of 25 kV Double Pole Vacuum Each 6.00 996323.00 5977938.00 Interrupter. 11 51(i) Supply of 50 kV double pole SF6 Each 2.00 556615.00 1113230.00 Circuit Breaker (2000A) 12 51(i) Erection of 50 kV double pole SF6 Each 2.00 15255.00 30510.00 Circuit Breaker (2000A) 13 55(a) Supply of 25 kV Potential Each 8.00 85932.00 687456.00 Transformer (PT) Type-I 14 55(a) Erection of 25 kV Potential Each 8.00 1100.00 8800.00 Transformer (PT) Type-I 15 56(a) Supply of 25 kV Lightning Arrestors Each 14.00 44248.00 619472.00 (42kV LA) 16 56(a) Erection of 25 kV Lightning Arrestors Each 14.00 1021.00 14294.00 (42kV LA) 17 57(b) Erection, Oil-filtration, Testing and Each 4.00 12498.00 49992.00 Commissioning of L.T. Supply Transformers (10 kVA). 18 57(b) Supply of L.T. Supply Transformers Each 4.00 82140.00 328560.00 (10 kVA) 19 58(a) Erection of 240V L.T. Distribution Each 2.00 1751.00 3502.00 Boards in the Control Room for 25 kVA L.T Supply Transformer. 20 58(a) Supply of 240V L.T. Distribution Each 2.00 95577.00 191154.00 Boards in the Control Room for 25 kVA L.T Supply Transformer. 21 58(b) Erection of 110V DC Distribution Each 2.00 1246.00 2492.00 Boards. 22 58(b) Supply of 110V DC Distribution Each 2.00 50390.00 100780.00 Boards. Total 85088310.00 Item- 9 Section-10B: Wire and Cable Items S No. Item No Description of Item Unit Qty Rate Amount CAO-C-NER-ELECTRICAL/NORTH EASTERN RLY 1 31(a) Installation of cable for Circuit Metre 2330.00 30.00 69900.00 Breakers & interrupter Control and indication Circuits (07 Core x 2.5 Sq. mm Copper) 2 31(a) Supply of cable for Circuit Breakers & Metre 2330.00 333.00 775890.00 interrupter Control and indication Circuits (07 Core x 2.5 Sq. mm Copper) 3 31(e) Supply of cable for Potential Metre 1240.00 123.00 152520.00 Transformer and 240V AC Supply Circuits (02 Core x 2.5 Sq. mm Copper). 4 31(e) Installation of cable for Potential Metre 1240.00 26.00 32240.00 Transformer and 240V AC Supply Circuits (02 Core x 2.5 Sq. mm Copper). 5 31(f) Installation of cable for 240V Heater Metre 2195.00 24.00 52680.00 Circuit. (02 Core x 04 Sq.mm Aluminium). 6 31(f) Supply of cable for 240V Heater Metre 2195.00 95.00 208525.00 Circuit. (02 Core x 04 Sq.mm Aluminium) 7 32(d) Supply of Aluminium XLPE Cable 02 Metre 175.00 219.00 38325.00 Core x 70 Sq. mm. 8 32(d) Installation of Aluminium XLPE Cable Metre 175.00 27.00 4725.00 02 Core x 70 Sq. mm. Total 1334805.00
Repair and Maintenance of Internal and External Electrification of NVDA Rest House Khargone Dist. Khargone including material, labour charges and testing etc. complete work.
Repair & Maintenance of Internal & External Electrification of NVDA Rest House Khargone Dist. Khargone including material, labour charges and testing etc. complete work.
Repair and Maintenance for External and Internal Electrification work of NVDA (ISP) Bediya Colony, Khargone including material, labour charges and testing etc. complete work.
Repair & Maintenance for External & Internal Electrification work of NVDA (ISP) Bediya Colony, Khargone including material, labour charges and testing etc. complete work.