Electric Emergent work in Shri Sundar Singh Bhandari District Hospital Amba Mata, Udaipur ( Part 3)
Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
Construction of Building less primary at PS Mehra Nerojal Under Samagra Shiksha Amount 45 77 lacs 2 Electrification work of primary school Mehra Nerojal Under Samagra Shiksha Amount 1 69 lacs 2nd call
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5.sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit,with modular switch,modular plate,suitable GI box and earthing the point with 1.5.sq.mm FRLS PVC insulated copper conductor single core cable etc as required
Work related to Shifting of 11 KV Power Line coming in between widening/renovation of Amritpur Jamrani motor road and Dam construction and Issuing 2000 KVA temporary connection under Electricity Distribution Division Nainital
LAYING OF LT CABLE & MAKING CONN. AT T/F
CA NO. GE AF NO.1 / GUR-50 / 2026-27 REPAIR / MAINTENANCE OF DIESEL GENERATING SET, SERVICE MAIN CABLE AT TECH AND DOMESTIC AREA EARTHING AND OTHER MISC E/M WORKS AT 13 BRD AND 16 BRD UNDER GE (AF) GURGAON NO.1.
M&L for monthly Inspection, maintenance and servicing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintenance as directed. Monthly Service : (a) Checking engine oil level and topping up as and when required . Note : Oil shall be measures and paid separately (b) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid separately (c) Checking of oil bath air cleaner level (d) Checking of exhaust system for leakage (e) Draining of sediment from fuel filter and fuel tank (f) Cleaning of air cleaner element (g) Checking engine alternator coupling, mounting bolts and alignment (h) Tighting all nuts, bolts, in alternator terminal block (i) Checking of alternator carbon brush and connections in alternator (j) Checking and tighting of all connection in DC control wiring. (k) Checking of all radiator rubber hose and replacement if required. Note : Hose pipe shall be measured and paid separately (l) Checking and recording oil pressure, water and oil temperature (m)Checking anti vibration mounting and replacement if required. Note : Anti vibration pad shall be measured and paid separately (n) Checking throttle linkage (o) Checking battery for cell test, electrolyte level, gravity and topping up to required level (p) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit. (q) Checking of AMF panel, all electrical connections etc. (r) Checking of earthing resistance (s) Cleaning of vegetation around the DG set up to 1.5 mtr area.
REPAIRS REPLACEMENT OF INTERNAL ELECTRIFICATION DB FITTINGS AND FIXTURES WITH CONNECTED WORKS AT OFFRS ACCN AND ORs JCOs MD ACCN IN ZONE G AREA UNDER AGE EM (N) OF GE (NORTH) SECUNDERABAD
M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete.
COSNTRUCTION OF MULTIPURPOSE HANGER (STEEL STRUCTURE) AT Pt. DINDAYAL UPADHYAY MEMORABLE HEALTH SCIENCE & AYUSH UNIVERSITY C.G. CAMPUS I/C. ELECTRIFICATION WORK AT DIST. RAIPUR(DN. NO.3, NAWA RAIPUR) (DEPOSIT WORK) (Without Escalation and Bonus)
Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: 12.19.2 With 2 metre long GI Pipes and 25 kg back filling compound.