Loading…
Loading…
10,167 results • Best match
The Work For Supply of Materil under Deposit Scheme in the Jurdiction Of Electricity Distribution Circle Akbarpurr (Ambedkarnagar)
REPAIR / MAINTENANCE OF INTERNAL ELECTRIFICATION, SUB MAIN WIRING, GEYSERS AND OTHER E/M WORKS IN SMQs, OMQs, AND OTM ACCN / MESSES AT AF-II UNDER GE (AF) JAMNAGAR NO.2
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than1.5 mtr below normal ground level, connected to galvanised earth lead wire mm as 4.0 mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate no. 3 including earth pit in PCC concrete 1:2:4 type B-1, Cast iron cover 10 mm thick hinged to CI frame , excavation and earth work in any type of soil and including protection pipe 15mm dia and water pipe GI tubing 20mm light grade with funnel and wire mesh connected to earthling test point complete all as specified and directed. Note: (i) Rates are inclusive of 7.5 m long GI earth wire 4.0 mm dia (ii) Rates of CI frame, RCC Pit cover, funnel and wire mesh included in the cost of item.
Balance work in Construction of pier for gate hoisting arrangement including providing power supply for gate operation & lighting arrangement over Barrage across Tunga bhadra river near Suguru village (phase-II) (catwalk,Electrification and Roof shelter)
Supplying of Earthing material and Digging of pit for providing GI pipe Earthing for lighting arresters Transformer Neutral and Transformer Metal parts -Ordinary soil complete as directed by Engineer ...
REPAIR / MAINT OF EXTERNAL ELECTRIC SUPPLY, LT UG CABLE, LT PANELS AND OTHER ALLIED WORKS AT AF STATION DWARKA AND KHAMBHALIYA UNDER GE (AF) JAMNAGAR NO.2
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50 m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50 mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 1991, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed.
REPAIRS REPLACEMENT OF INTERNAL ELECTRIFICATION FITTINGS AND FIXTURES IN OTM ACCN OF 1TB AND 2 TB OF HQ 1 EME CENTRE 7 ENG REGT IN ZONE D AREA UNDER AGE EM (N) OF GE (NORTH) SECUNDERABAD
M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete.
REPAIR/ MAINT TO OVER HEAD/ UNDER GROUND ELECTRIC SUPPLY LINES AND OTHER ALLIED WORKS SERVICES UNDER GE NARANGI.
M & L in repair for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.