Loading…
Loading…
10,167 results • Best match
Execution of Zonal works of Electric Loco Shed Maintenance under the jurisdiction of SSE(Works)/South/Bilaspur for the period ending 30-06-2027.
Execution of following works and throwing away the cum sludge at a location identified & as directed with a free lead of 100m. For extra lead payment will be made as per USSOR-2010 (Desludging of septic tanks.) BILASPUR DIVISION-ENGINEERING/SOUTH EAST CENTRAL RLY
Construction of Control Room Building Extension with Electrification, color work in existing control room building and ancillary civil work at various substation of AM Division Bhuj under Anjar Circle
CONSTRUCTION OF FIRST AND SECOND FLOOR BUILDING AT DISTRICT OFFICE OF FOOD AND DRUG ADMINISTRATION, DISTRICT-JANJGIR-CHAMPA (C.G.) i/c INTERNAL WATER SUPPLY, SANITARY FITTING, ELECTRIFICATION WORK ETC.
For Providing Internal Electrification, CCTV Camera, UPS System, Computer Cabling, Wi-Fi, EPABX, PA System and VRV Air Conditioning 6 No. Gate and 1 No. Gate HCM House Bhopal.
General Description of work : For Providing Internal Electrification, CCTV Camera, UPS System, Computer Cabling, Wi-Fi, EPABX, PA System and VRV Air Conditioning 6 No. Gate and 1 No. Gate HCM House Bhopal. 1st Call. P. A. C. 6370149.00 on Electrical SOR 01-01-2024 and Non SOR, Completion period 335 Days (i/c rainy season)
Electrification, maintenance, and operation work for a period of one year for the buildings constructed in Group Housing blocks GH-3 and GH-4 of the Madhuban Bapudham Scheme.
Supply & Laying of 10 Sqmm X 2 core PVC sgeatged/XLPE power cable aluminium conductor XLPE isulated and FRLS PVC sheathed armoured cable conforming to relevant IS etc. in existing trunch/HDPE piep complete in all respect as per direction of E/I. CCI/Policap/Universal/Havills/Gloster.
REPAIR/ MAINT OF INTERNAL ELECTRIFICATION AND REPAIR/ MAINT OF WATER SUPPLY DISTRIBUTION LINES, PUMP, FOUNTAIN and CLEANING OF SUMP/ TANK ALONGWITH ITS CONNECTED WORKS AT SANGLI APARTMENTS UNDER GE NEW DELHI
M&L in replacement for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25X4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover etc complete all as specified and directed.