Loading…
Loading…
10,384 results • Best match
THE SUPPLY INSTALLATION OF STADIUM MAST AT MUKKOODU STADIUM IN KUNDARA GRAMA PANCHAYATH. GENERAL ELECTRICAL WORK UNDER KUNDARA LAC MLA SDF SCHEME OF SRI. P C VISHNUNATH MLA.
Supply installation testing and commissioning of 10 Mtr Octogaonal Pole with 4 Numbers of 250W LED Flood lights including all Accessories and KSEB Charges
Balance Electrical work in New Building and Upgradation of Electrical work in Science Block old Building at Government College for Women, Gohana, District Sonipat.
[23.28.1.3]Supplying, installation, Testing and Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , UGR (Unified Glare Rating) ( 19, Flicker free (flicker should be below 5%), life time (LED,Driver and electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 and (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 3. Powder coated die cast /Extruded aluminum Body including trim 12-15 watt [Rate]
Comprehensive Annual Repair and Maintenance ARMO of Civil and Electrical works at ESIC Hospital Naroda Gujarat
Comprehensive Annual Repair and Maintenance (AR & MO ) of Civil and Electrical works at ESIC Hospital Naroda, Gujarat. (Including all taxes)
Operation & Maintenance work for sewage treatment plant (20.20 MLD) based on SBR with MCC panel room, DG set and all contingent civil, electrical, mechanical, piping and instrumentation works of entire system for 5 years at Valsad, District: Valsad, Gujarat (2nd call)
MCC panel room, DG set and all contingent civil, electrical, mechanical, piping and instrumentation works
Laying of Additional circuit of AB cable in 12 Nos. of various feeder under KESCo., Kanpur
Laying of AB Cable (3x120+1x95+1x16) Sq.mm Including (All Fitting Accessories Providing & Fixing By Contractor M.S.Holding Clamp PCC, M.S. Holding Clamp 4.5"/ 5.5" 50x6 mm, Suspension Clamp With I Hook, Dead End With I Hook,Pericing Connector 120-120 mm, Neutral Connector,Dead End Seeling Cap,NUT Bolt With Double Washer.)As per Technical standard Approved by Kesco/ Uppcl.
Laying of Additional circuit of AB cable in 16 Nos. of various feeder under KESCo., Kanpur
Laying of AB Cable (3x120+1x95+1x16) Sq.mm Including (All Fitting Accessories Providing & Fixing By Contractor M.S.Holding Clamp PCC, M.S. Holding Clamp 4.5"/ 5.5" 50x6 mm, Suspension Clamp With I Hook, Dead End With I Hook,Pericing Connector 120-120 mm, Neutral Connector,Dead End Seeling Cap,NUT Bolt With Double Washer.)As per Technical standard Approved by Kesco/ Uppcl.