Provision of DC Track circuit for dual detection (Hitachi make EI) in various station yards of Kharagpur division.
... Supply is covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure ...
SPL REPAIR WKS TO UNDER GROUND CABLE SIZE 25 SQMM 3 PHASE 4 CORE (LENGTH 300 MTR) WITH 02 BUS BAR CHAMBER AND 02 MAIN LIGHT PANEL BOARD NEAR BLDG NO T-135 (COY OFFICE) TO BLDG NO T-140 (COOK HOUSE) INCL BLDG NO T-711 (TM LINE) OF 118 (I) INF BDE GP S
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and as directed by the Engineer - in - Charge.
Repair and maintenance work of traffic barrack at Police Line Commissionerate Jodhpur
... FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made... for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
REPAIR/MAINT LT SWITCH GEAR, PANEL, UG CABLES AND ALLIED WORKS AT CERTAIN UNIT AREA, TELIPARA I AND TELIPARA II OF SOUTH ZONE UNDER GE (NORTH) BINNAGURI
Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
REPAIR/MAINT OF HT 33/11 KV OH LINE/ UG CABLE, HT VCBS, RMUS AND TRANSFORMERS INSTALLED AT DOMESTIC AREA, 3LU AND SITE 1A AND 1B AT AFS JODHPUR
Sfifting of 11/0.433 KV distribution transformer of capacity 500 / 630 KVA from technical area to 33/11 KV New MRS by diconnecting all cable and earthings and installation, commissioning and testing complete including filteration of transformer oil and making all connection of cable and earthing complete all as directed.
SPECIAL REPAIR REPLACEMENT OF TRANSFORMER AND ALLIED WORKS UNDER GE MCTE MHOW
M&L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground... earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 3 of SSR part 1 Including neccessary excavation in disintergratedand hard soil ...