Loading…
Loading…
10,737 results • Best match
OPERATION AND GUARDING OF THE PUMPING MACHINERY AT KARIMPUR JALANGI W/S SCHEME, KARIMPUR-I, DIST-NADIA UNDER EASTERN MECHANICAL DIVISION., P.H.E. DTE.
Supervision Charges for electrical installation by licensed electrician as per I.E. Rules 1956, read with latest amendments, overhead expenditures as per specification and direction of EIC.
REPAIR MAINT OF BOREWELLS, DG SETS AND CONNECTED WORKS OF WATER SUPPLY SYSTEM UNDER GE AF PALAM, DELHI CANTT-10
Supply, laying and testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3½ core complete all as specified and directed. Note for Ser item No. 57 to 59:- The excavation and earth work shall be measured and paid seperately under respective items of BOQ.
Relining of E Minor from RD 0.000 to 14.000 of Gang Canal System
... FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made... for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR - 2 x 2.5 sq. mm. + 1x1.5sqmm
PROVISION OF MODERN SEWAGE TREATMENT PLANT AT SITE R AT AF STATION THANE
Notes for item Nos. 42 and 43:- (i) Earthing is to be done infront of the Engr-in-Charge. (ii) Test results of earthing is to be submitted by the contractor for all earthings. (iii) The contractor shall give written guarantee for maintenance earth resistance ...
03 - Construction of 2 Class Rooms, Toilets for Disabled-Girls-Boys, Drinking Water Facility and Staircase) at GPS Lalukhera, BLOCK - Bhadesar, Dist - Chittorgarh
... FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made... for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Development of Hostel BHSS Badugam
Wiring for lighting circuits/ inverter circuits/ 6- 10 amp power plugwith 2X2.5 sq.mm FRLS PVC insulated copper conductor Havell/Polycab Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 2.5 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.