Shifting of existing LTUG Cable and renewal of Street light arrangements at Arignar Anna Government Hospital of Indian Medicine Campus, Arumbakkam, Chennai-106
Renewal by Supply and providing cable end termination of 4 x 16 sq.mm. PVC insulated SC unsheathed copper conductor with necessary copper cable sockets by crimping etc with electrical connection complete.
Revamping of Electrical works in Muthamizh Arignar Kalaignar Thiraiarangam in the Iyal Isai Nadaka Mandram Campus at Greenways Road, Adyar, Chennai-28.
Supply and Installation of 16 core belden make snake cable, microphone cables, speaker cables, power cables, HDMI cables, EP to Phono cables, HDMI splitter and other all type of required connectors and cables for the entire audio system installation with concealed wiring on wall, floor and ceiling with suitable pvc pipes. Make: Branded /Eq.
Renewal and supply installation testing and commissioning of 8 person passengers lift for Honble Chief Minister at Gate No.1 at main building, Secretariat, Chennai-9
Renewal of the Old Lift and Design, Supply, Installation and Commissioning of 1no.8 Person Hon'ble Chief Minister LIFT elevator with stainless steel finish panels Serving Ground + 1 Floor with the following specifications. [ Kone and Equivalent ] one passenger elevator of the IMonospace series, model PWI08/10-19, designed to carry a load of 544 kg or up to eight persons. The elevator operates at a speed of 1.0 m/s and serves a total of two stops with two openings, configured with a single entrance car. The system is arranged under a simplex full collective control mode, ensuring efficient and responsive passenger handling. The total travel height of the elevator is 5.07 meters, with the MAP position located at the topmost floor. The elevator car has internal dimensions of 1100 mm in width, 1300 mm in depth, and 2200 mm in height, while the landing door opening measures 800 mm wide by 2000 mm high. The doors are designed as two-panel, centre-opening, ensuring smooth passenger movement and optimal shaft utilization.
Provision of Ductable Air conditioning facilities at the newly constructed Multi-purpose Hall at Tiruvallur Collectorate in Tiruvallur District.(Second Call)
Supply, Installation, Testing and Commissioning of 8.5 TR norminal capacity ceiling suspended ductable air conditioner with the following components. 5.5 TR capacity ceiling suspended Ductable Air conditioner high tech,low height,low noice level indoor unit with fin and tube type cooling coil,Detachable type drier provided in refrigerant cicuit to reduce moisture content multi stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil,with required valves,directly coupled blower to reduce troubles and wear & tear compared to belt drive blower.Thermostatic expansion valve lift and pull type aluminum framed durable,washable air filter.Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 45 F suction temperature Auto reset type HP/LP safety cut to improve reliability of compressor.
Provision of 160 KVA Diesel Generator Set for linear accelerator machine in Radiation Oncology Block at Rajiv Gandhi Government General Hospital, Chennai-3
Supply, testing, commissioning and handing over of 1 No 160KVA Diesel Generator set with standard control panel of 0.8P.F.Three phase 415/ 420 Volts, 50C/S 1500 RPM as detailed below. 1. ENGINE: Water cooled diesel engine suitable for Generator application with a shaft output of 310 BHP at 1500 RPM under NTP conditions as per BSS 5514/ IS 10000. The Engine shall comprise the following standard scope of supply. (Make Kirloskar / Cummins / Ashok Leyland / Greaves / Equivalent) 1. Dry type Air cleaner 2. Expansion bellow 3. Radiator, Radiator fan and mounting 4. Air to air charge cooler 5. Exhaust Gas turbo charger 6. Lube oil cooler and Lube oil filter 7. Fuel filter (pre and Micro) 8. In-line Mono-block fuel injection pump with governor and fuelfeed pump 9. Electronic governor 10. 24V Battery charging alternator 11. 24V Volt electric starter motor 12. Engine test Certificate 13. Residential Muffler 14. Fly wheel with starter ring. Engine Instrument panel mounted Engine control panel consisting of ON/OFF/START Key Lube oil pressure gauge, Oil temperature gauge, high water temperature gauge and electronic hour meter and RPM indicator.
Annual Maintenance for Comprehensive Servicing, Maintenance and Operation of 4 Nos. of 375 TR capacity Centralized AC Chiller plants at NKM building, Secretariat, Chennai-9 for the year 2026-2027 (04/2026 to 03/2027)
Annual Maintenance for Comprehensive servicing, Maintenance and operation of 1500TR (4 x 375 TR) capacity air cooled screw chillers complete comprising preventive & breakdown maintenance, repair of compressor and associated components and spares like expansion valve, loading and unloading coil switch, pressure cut out switches, oil switch, microprocessor based controller and other electrical components in the system, refrigent piping and consumables like V-belt, bearings, descaling chemicals, charging of oil and refrigerant including operation of the chiller, AHU's pumps by person suitably in the field of refrigeration, monthly servicing and ensuring proper operation of the Auxiliary HVAC system.