Loading…
Loading…
59,730 results • Best match
Provision of Solar Street Light for retrofitting under Tamil Nadu Climate Change Mission (TNCCM) in Govt. Stanley Hospital, Chennai-01.
MEERUT GARH ROAD PAR RK RESORT SE KANTHI MATA MANDIR TAK STREET LIGHT POLE INSTALLATION WORK
Renewal by providing synchronizing panel of 2 x 2030 KVA DG sets, Power cables and allied works at Tamil Nadu, Government Multi Super Speciality Hospital, Omandurar Government Estate, Chennai-2
GARH MEERUT ROAD PAR VATIKA NURSERY SE NAHAR TAK STREET LIGHT POLE INSTALLATION WORK
Provision for MV, APFC Panel, Cables, Relay works in existing HT panel and Substation allied works in the Government Medical College Hospital at Tiruvallur in Tiruvallur District
Design, Supply, erection, testing and commissioning of 2000A draw out type floor mounted MV cubical panel board suitable for operation on 415 V 3 phase, 50 Hz A.C supply, dust and vermin proof and accommodating the following ACB as Incomer unit & Bus-coupler with the following items of work complete to satisfy the latest IE rules and CEIG guidelines with Bus bar chambers, Main switches chambers and cable entry chambers. Bus bar chamber: Supply and fixing of suitable bus bar chamber made up of 16SWG MS sheet steel(1.8mm) with 4Nos. 3” X 1/2” tinned copper bus bar for 3 phases and neutral and of earth bus of size 1” X 1/8" tinned copper bus(25mm x 3mm) on suitable bus bar insulator(Epoxy insulator) with maximum creepage distance and supported on MS Base channel frame work of size 4”X 2”X ¼”–1Set Main Switches Chamber: Incoming 1)Supply and fixing of 1 Nos. 1250 A 4 pole 433V LT ACB confirming to IS13947–2 IEC 60947–2 with suitable capacity and breaking capacity of drawout 50 KA breaking c capacity with all accessories for standard horizontal manual draw out type ACB equipped with auxiliary contacts and all accessories for closing and opening operation with Microprocessor Based SR 18 G relay, over current trip device adjustable to LTD, STD and release for over current protection UV release with time delay, EF release short circuit protection, Mains CTs for 3 phases lockout, features, separate mold base for each pole for easy maintenance all relevant protection safety accessories as per CEIG, IE rules in force with inter connection and terminations as required in specification
Rewiring and Renewal of fittings, fans, and power mains in Hostel building and power mains for workshop and street light cable in Govt. Institute of Rehabilitation Medicine and Artificial Limb Centre, K.K. Nagar, Chennai-78
Renewal by supply and providing cable end termination of 3-1/2 x 120 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.