Loading…
Loading…
60,909 results • Best match
Repairing and Renovation works of Principals Quarters including Electrical Works, Boundary and Sanitary Plumbing Works at Nistarini College, Purulia
Repairing and Renovation works of Principal’s Quarters including Electrical Works, Boundary and Sanitary Plumbing Works at Nistarini College, Purulia
GENERAL Upgradation of rest house Thamarassery Upgradation of PWD Rest House at Thamarassery for promoting Tourism - Balance Electrical Work General Electrical Work
Work Name:GENERAL-Upgradation of rest house Thamarassery-Upgradation of PWD Rest House at Thamarassery for promoting Tourism - Balance Electrical Work-General Electrical Work
(2) RMO Electrical and Mechanical services UPS, Servo Voltage Stabilizer, DG Set and Sub-Station at Delhi State Cancer Institute, Dilshad Garden, Delhi. Sub Head Day to Day Maintenance of E.I. Works, Sub Station
nternal Electrical Installation work for the construction of Vulnerable Witness Deposition Court (VWDC) at the Basirhat Sub-Divisional Court , Basirhat North 24 Parganas.-E.I and AC Installation.
SUB HEAD 6 -- LAYING OF CABLES Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire as per GS. -- [ 2(c)/F-1 ] [ For 4 Core 25 Sq mm. ]
Electrical installation and concealed wiring work of newly constructed Control Room Building at Balarampur 33/11 KV Sub Station under Purulia Division..
Supply & Laying of one cable of (1.1 KV Grade ) 2C 6 sqmm PVC Cable through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand [ For 2 core 6 sq mm] [F-3/4(a)]
Electrical work
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point